Figure 5.  Left Log in Proper Position

Figure 6.  Left and Right Log in Proper Position

3.  Left log placement (SRV2208-705) :  Mate rear and front 

faces of left log with indentations on rear and base logs 

as shown in Figure 4 and Figure 5.  Slide the left log 

back.

4.  Right log placement (SRV2208-706) : Place the right log 

by positioning the front “V” of the log on the indentation 

on the base log and resting the rear of the log on the 

flat area of the rear log.  See Figure 4 and Figure 6.

5.  Figure 6 shows the Left and Right Logs properly placed.  

Both Left and Right Logs should sit securely on the rear 

and corresponding base logs.

BASE LOG

REAR  FACE

FRONT FACE

REAR LOG

FRONT “V”

RIGHT LOG

LEFT LOG

REAR LOG

FLAT 

AREA

BASE LOG

Figure 4.  Left Log and Right Log Reference Points

D

A

C

B

LOG A 

SHOULD NOT

COVER ANY 

PORTS

LOG E

LOG F

Содержание CNXT4236IH-D

Страница 1: ...240 MH Series in Canada This appliance is only for use with the type s of gas indicated on the rating plate This appliance is not convertible for use with other gases unless a certified kit is used DA...

Страница 2: ...rmation Serial Number Type of Gas Model Number Not Not for for use use with with solid solid fuel fuel Ne Ne doit doit pas pas entre entre utilise utilise avec avec un un combustible combustible solid...

Страница 3: ...Typical Appliance System 19 B Design and Installation Considerations 20 C Tools and Supplies Needed 20 D Inspect Appliance and Components 20 5 Framing and Clearances A Selecting Appliance Location 21...

Страница 4: ...hipping Materials 57 C Clean the Appliance 57 D Accessories 57 E Ember Placement 57 F Place the Lava Rock and Vermiculite 58 G Install the Log Assembly 59 H Fixed Glass Assembly 61 I Install Trim and...

Страница 5: ...begins on the date of original purchase In the case of new home construction warranty coverage begins on the date of first occupancy of the dwelling or six months after the sale of the product by an...

Страница 6: ...OVE WARRANTY EXCLUSIONS This warranty does not cover the following Changes in surface finishes as a result of normal use As a heating appliance some changes in color of interior and exterior surface f...

Страница 7: ...tion Material which will not ignite and burn Such materials are those consisting entirely of steel iron brick tile concrete slate glass or plasters or any combination thereof Materials that are report...

Страница 8: ...vented gas fu eled heating appliance or equipment The sign shall read in print size no less than one half 1 2 in in size GAS VENT DIRECTLY BELOW KEEP CLEAR OF ALL OB STRUCTIONS Inspection The state or...

Страница 9: ...n Teach children to NEVER touch the fireplace Consider not using the fireplace when children will be present Contact your dealer for more information or visit www hpba org safety information To preven...

Страница 10: ...See your dealer if you have questions H IPI Battery Tray Battery Installation The IntelliFireTM Plus system has a battery backup option Battery longevity and performance will be affected by the servi...

Страница 11: ...ch will become inactive once an optional remote control RC200 RC300 is programmed to the control module Note that the control module will always ignite the fireplace on HI and remain so for the initia...

Страница 12: ...ying appliance Hot while in operation DO NOT touch Keep children clothing furniture gasoline and other liquids having ammable vapors away DO NOT operate the appliance with xed glass assembly removed c...

Страница 13: ...20 to 40 minutes Odor from appliance When first operated this appliance may release an odor for the first several hours This is caused by the curing of the paint and the burning off of any oils remain...

Страница 14: ...maintained your fireplace will give you many years of trouble free service We recommend an nual service by a qualified service technician Doors Surrounds Fronts Frequency Annually By Homeowner Tools n...

Страница 15: ...tion when cleaning these areas Screw tips that have penetrated the sheet metal are sharp and should be avoided Remove all foreign objects Verify unobstructed air circulation Burner Ignition and Operat...

Страница 16: ...de panel forward See Figure 3 2 2 To remove the side refractory panels slide the panel forward as shown in Figure 3 3 NOTICE The back panel may fall forward when side panels are removed Damage could o...

Страница 17: ...gure 3 8 Remove Screws from Burner Assembly Rear Corners Figure 3 7 Remove Screws from Log Tabs Figure 3 9 Remove Burner Skirt 8 Remove burner skirt by removing 4 screws See Figure 3 9 9 Bend down gra...

Страница 18: ...skirt need to be removed in order to identify burner See Figure 3 12 for burner identification chart CD4236IR D LP LP CNXT4236IH T D NG LP CD4236IR D NG CD4842IR D LP LP CNXT4842IH T D NG LP CD4842IR...

Страница 19: ...TING ROOF RAFTERS SECTION 8 C FRAMING HEADED OFF IN CEILING JOISTS SECTION 8 C GAS LINE SECTION 11 MANTEL AND MANTEL LEG SECTION 5 D SURROUND HEARTH EXTENSION VENT PIPE SECTIONS 7 and 8 OPTIONAL WALL...

Страница 20: ...d in complete or substitute components Keep appliance dry C Tools and Supplies Needed Before beginning the installation be sure that the following tools and building supplies are available Tape measur...

Страница 21: ...flect typical installations and are FOR DESIGN PURPOSES ONLY Illustrations diagrams are not drawn to scale Actual installation may vary due to individual design preference Figure 5 1 Appliance Locatio...

Страница 22: ...regions where cold air infiltration may be an issue the inside surfaces may be sheetrocked and taped for maximum air tightness To further prevent drafts the wall shield and ceiling fire stops should...

Страница 23: ...es 1 in 25 mm min to perpendicular wall A 3 1 2 in 89 mm min from fireplace opening to perpendicular wall B Mantel Leg or Perpendicular Wall Top of Appliance Drywall A B Figure 5 4 Mantel Leg or Wall...

Страница 24: ...2 FT MIN 20 INCHES MIN H MIN MINIMUM HEIGHT FROM ROOF TO LOWEST DISCHARGE OPENING 6 Termination Locations Fire Risk Maintain vent clearance to combustibles as specified DO NOT pack air space with ins...

Страница 25: ...r i V G X V H A V V H Electrical Service V K V K V L C V N 6 inches non vinyl sidewalls 12 inches vinyl sidewalls O 18 inches non vinyl soffit and overhang 42 inches vinyl soffit and overhang P 8 ft Q...

Страница 26: ...mm vertical run A length of straight pipe is allowed between two 45 elbows see Figure 7 1 Figure 7 1 7 Vent Information and Diagrams B Vent Table Key The abbreviations listed in this vent table key a...

Страница 27: ...agrams Top Vent Horizontal Termination Two 45 Elbows Installation requirements to replace the first 90 elbow with two 45 elbows 4 ft min 1 22 m 20 ft max 6 1 m 1 4 in max 6 mm Figure 7 3 Horizontal te...

Страница 28: ...y from vent pipe may cause fire Example DVP pipe 3 ft min vertical 11 ft max horizontal SLP pipe 7 ft min vertical 11 ft max horizontal Fire Risk When using DVP HRC SS and DVP HRC ZC SS termination ca...

Страница 29: ...allowed 1 2 ft 152 mm Not allowed 1 ft 305 mm 2 ft 610 mm 1 1 2 ft 457 mm 2 ft 610 mm 2 ft 610 mm 4 ft 1 2 m 2 1 2 ft 762 mm 4 ft 1 2 m 3 ft 914 mm 6 ft 1 8 m 4 ft 1 2 m 10 ft 3 1 m 6 ft 1 9 m 14 ft 4...

Страница 30: ...ntinued Three Elbows V1 Min H1 Max V2 Min H2 Max Elbow only 2 ft 610 mm 0 in 0 mm 1 ft 305 mm 6 in 152 mm 3 ft 914 mm 6 in 152 mm 2 ft 610 mm 1 ft 305 mm 6 ft 1 8 m 1 ft 305 mm 6 ft 1 8 m 2 ft 610 mm...

Страница 31: ...ical baffle 1 Remove the screws holding the refractory retainers in place See Figure 7 8 Figure 7 8 Remove Refractory Retainers 2 Remove the retainers 3 Remove the right or left side refractory only o...

Страница 32: ...4 3 3 3 3 3 3 35 ft 3 4 3 4 3 4 3 3 40 ft 3 4 3 4 3 4 3 4 50 ft 3 4 3 4 3 4 3 4 5 Orientate and align the two pieces of the flue restrictor as shown in Figure 7 13 6 Match the amount of vertical you h...

Страница 33: ...V2 H1 60 ft 18 3 m Maximum No specific restrictions on this value EXCEPT V1 V2 H1 cannot exceed 60 ft 18 3 m Note If the DVP 2SL or DVP SLP24 adapter is used with SLP pipe you MUST subtract one numbe...

Страница 34: ...D HORIZONTALLY H1 H2 V1 V2 V1 H1 H2 V2 V1 V2 Minimum H1 H2 Maximum Elbow only 1 ft 305 mm 1 ft 305 mm 6 in 152 mm 2 ft 610 mm 2 ft 610 mm 1 ft 305 mm 2 ft 610 mm 2 ft 610 mm 2 ft 610 mm 4 ft 1 2 m 4 f...

Страница 35: ...42IT D CNXT4236IH D CNXT4842IH D 2360 900 Rev i 5 17 Figure 7 16 Rear Vent Horizontal Termination No Elbow One 45 Elbow H1 H1 18 in 457 mm Maximum Do not use a 45 elbow in corner installations Use two...

Страница 36: ...5 mm Back to Back 90 Elbows 1 ft 305 mm 2 ft 610 mm 2 ft 610 mm 6 in 152 mm 2 ft 610 mm 4 ft 1 2 m 3 ft 914 mm 1 ft 305 mm 2 ft 610 mm 5 ft 1 5 m 3 ft 914 mm 2 ft 610 mm 4 ft 1 2 m 7 ft 2 1 m 3 ft 914...

Страница 37: ...1 2 m 12 ft 3 7 m 15 ft 4 6 m V1 H1 H2 H3 40 ft 12 2 m Maximum H1 3 ft 914 mm Maximum H1 H2 H3 20 ft 6 1 m Maximum CXNT4842 Series H1 Maximum V1 Minimum H2 H3 H1 H2 H3 Max 0 ft 0 mm Back to Back 90 El...

Страница 38: ...m 3 ft 914 mm 2 ft 610 mm 5 ft 1 5 m 3 ft 914 mm 7 ft 2 1 m 4 ft 1 2 m 8 ft 2 4 m 5 ft 1 5 m 8 ft 2 4 m V1 H1 40 ft 12 2 m Maximum H1 8 ft 2 4 m Maximum V1 Minimum H1 H2 Maximum Back to Back 90 Elbows...

Страница 39: ...12 2 m Maximum No specific restrictions on this value EXCEPT V1 H1 H2 H3 cannot exceed 40 ft 12 2 m Maximum H1 H2 H3 8 ft 2 4 m Maximum H1 Maximum V1 Minimum H2 H1 H2 Maximum 2 ft 610 mm 6 in 152 mm 2...

Страница 40: ...ield Firestop Heat Shield WALL 3 in 76 mm top clearance 1 in 25 mm clearance bottom sides Heat Shield Wall Shield Firestop Heat Shield WALL 3 in 76 mm top clearance 1 in 25 mm clearance around vertica...

Страница 41: ...around the vent Insulation must be kept back from the pipe to prevent overheating Figure 8 4 Installing Ceiling Firestop Figure 8 5 Installing the Attic Shield INSTALL ATTIC INSULATION SHIELDS BEFORE...

Страница 42: ...knockout from the fireplace and discard it see Figure 8 6 Center the duct collar around the exposed hole and attach it to the fireplace with 3 screws Note Do this BEFORE final positioning of fireplac...

Страница 43: ...oss the rectangles next to the disk For rear vent skip this step Figure 9 2 Remove the white gasket material covering the seal cap WARNING Risk of Fire DO NOT remove the installed piece of insulation...

Страница 44: ...retaining band out and use to remove the seal cap Figure 9 10 Discard the vent cap remove and discard the insulation basket NOTICE Once the seal cap has been removed it CANNOT be reattached Figure 9 6...

Страница 45: ...n insulation Make sure insulation and other materials are secured DO NOT notch the framing around the appliance standoffs Failure to maintain air space clearance may cause overheating and fire The dia...

Страница 46: ...predrilling holes DO NOT penetrate inner pipe For 90 and 45 elbows that are changing the vent direction from horizontal to vertical one screw minimum should be put in the outer flue at the horizontal...

Страница 47: ...ure 10 1 Only outer pipes need to be sealed All unit collar pipe slip section elbow and cap outer flues shall be sealed in this manner unless otherwise stated Figure 10 5 Adding Venting Components WAR...

Страница 48: ...be supported every 8 ft 2 44 m after the maximum allowed 25 ft 7 62 m of unsupported rise Vertical runs originating off the rear of the appliance or after any elbow must be supported every 8 ft 2 44 m...

Страница 49: ...of the cathedral ceiling support box on the outside roof Remove shingles or other roof covering as necessary to cut the rectangular hole for the support box Cut the hole 1 8 in 3 mm larger than the s...

Страница 50: ...MIN 20 INCHES MIN H MIN MINIMUM HEIGHT FROM ROOF TO LOWEST DISCHARGE OPENING Figure 10 15 NOTICE Failure to properly caulk the roof flashing and pipe seams may permit entry of water Caulk the gap betw...

Страница 51: ...on WARNING Risk of Fire To prevent overheating and fire heat shields must extend through the entire wall thick ness DO NOT remove the heat shields attached to the wall shield firestop and the horizont...

Страница 52: ...de edges of cap When installing a horizontal termination cap follow the cap location guidelines as prescribed by current ANSI Z223 1 and CAN CGA B149 installation codes and refer to Section 6 of this...

Страница 53: ...leak check solution DO NOT use open flame Fittings and connections could have loos ened during shipping and handling WARNING Risk of Fire DO NOT change valve settings This valve has been preset at th...

Страница 54: ...oper operation of the appliance WARNING Risk of Shock or Explosion DO NOT wire IPI controlled appliance junction box to a switched circuit Incorrect wiring will override IPI safety lockout Refer to Fi...

Страница 55: ...ction box inward to disengage it from the outer shell see Figure 12 2 Pull the electrical wires from outside the appliance through the opening into the valve compartment and secure wires with a Romex...

Страница 56: ...isk of Fire DO NOT apply combustible materials beyond the minimum clearances Comply with all minimum clearances to combustibles as specified in this manual Overlapping materials could ignite and will...

Страница 57: ...nty E Ember Placement WARNING Risk of Explosion Follow ember place ment instructions DO NOT place ember directly over burner ports Replace ember material annually Improp erly placed ember material int...

Страница 58: ...rock in an even layer just heavy enough to cover the metal surface Stay within the zone indicated in Figure 14 3 It is not necessary to use the entire bag Save the remaining amount for future use WAR...

Страница 59: ...logs 2 Log A placement SRV2208 702 Install Log A as shown in Figure 2 and Figure 3 Locate log placement bracket and placement tabs shown in Figure 2 Align holes in bottom of log with alignment tabs Pl...

Страница 60: ...log placement SRV2208 706 Place the right log by positioning the front V of the log on the indentation on the base log and resting the rear of the log on the flat area of the rear log See Figure 4 and...

Страница 61: ...glass assembly latches into the groove on the glass frame Air Shutter Settings I Install Trim and or Surround Install optional trim kits and or surrounds using the instructions included with the acce...

Страница 62: ...ximately 095 in 2 41 mm to 135 in 3 43 mm 2 Pilot won t light there is no noise or spark A No power transformer installed incorrectly or depleted batteries Verify that transformer is installed and plu...

Страница 63: ...n module and sense lead is at least 0 14 microamps Verify correct pilot orifice is installed and gas inlet is set to pressure specifi cations Polish flame sensing rod with fine steel wool to remove an...

Страница 64: ...s refer to Section 5 Figure 16 1 Appliance Dimensions CNXT4236IT D and CNXT4236IH D Models A B C D E FRONT VIEW TOP VIEW LEFT SIDE RIGHT SIDE F G H I J K L M O P GAS LINE ACCESS Q R N Location Inches...

Страница 65: ...tion Inches Millimeters J 21 533 K 11 11 16 297 L 35 1 2 901 M 17 3 4 451 N 8 1 2 216 O 2 7 8 73 P 8 1 2 216 Q 1 25 R 42 7 8 1089 Location Inches Millimeters A 48 1219 B 43 1 8 1096 C 34 3 8 873 D 36...

Страница 66: ...16 mm 824 579 910 37 173 814 849 SIM 42C CNXT 4842IT D CNXT 4842IH D in 39 7 16 24 3 4 42 13 16 1 7 16 6 13 16 33 15 16 35 3 8 mm 1002 629 1087 37 173 862 899 Figure 16 3 Decorative Front dimensions S...

Страница 67: ...172 819 848 CRAFT 42C CNXT 4842IT D CNXT 4842IH D in 39 5 16 23 13 16 42 13 16 1 3 16 6 3 4 34 1 8 35 5 16 mm 999 605 1087 30 172 867 897 Figure 16 4 Decorative Front dimensions Craftsman and Jamesto...

Страница 68: ...0 in 254 mm 1 1 2 in 38 mm 5 in 127 mm 12 in 305 mm UP DVP HVS Vent Support DVP WS Wall Shield Firestop DVP FS Ceiling Firestop DVP45 45 Elbow DVP Pipe see chart Effective Height Length 4 7 8 in 276 m...

Страница 69: ...f 1 1 2 in 38 mm The heat shield is designed to be used on a wall 4 in to 7 1 4 in 102 mm to 184 mm thick If wall thickness is less than 4 in 102 mm the existing heat shields must be field trimmed If...

Страница 70: ...37 mm RF12M Roof Flashing Multi pak Cap Shield DRC RADIUS 13 7 8 in 352 mm 9 1 2 in 241 mm 14 in 356 mm COOL ADDM Cap Shield 11 5 8 in 295 mm 5 3 4 in 146 mm 7 1 8 in 181 mm 12 1 8 in 308 mm DVP BEK2...

Страница 71: ...in 429 mm DVP HPC High Performance Cap 1 in 25 mm 14 in 356 mm 3 8 in 10 mm 1 in 25 mm 7 1 4 in 184 mm 7 3 4 to 10 3 8 in 197 to 264 mm DVP FBHT FireBrickTermination Cap DVP TB1 Basement Vent Cap 12 i...

Страница 72: ...VI WH100 16 IN 406 mm 15 IN 381 mm 16 11 16 IN 424 mm 9 3 16 IN 233 mm 4 1 2 IN 114 mm 16 11 16 IN 424 mm 13 5 8 IN 346 mm 12 1 2 IN 318 mm 12 1 2 IN 318 mm 20 3 4 IN 527 mm 13 5 8 IN 346 mm PVI SLP B...

Страница 73: ...the appliance and are ordered separately from PVLP SLP Contact your dealer to order Note The PVLP SLP requires a PV IPI CK be installed on this appliance The PV IPI CK is ordered separately from the...

Страница 74: ...6 mm 10 7 8 in 276 mm 10 1 2 in 267 mm 3 87 Effective Length 5 3 4 to 8 3 8 in 146 to 213 mm 5 1 2 in 140 mm 8 3 8 in 213 mm Fire Risk When using DVP HRC SS and DVP HRC ZC SS termination caps on top v...

Страница 75: ...51 305 8 3 4 in 222 mm 6 1 2 in 165 mm 6 5 8 in 168 mm 6 in 152 mm 6 1 2 in 165 mm 6 5 8 in 168 mm 9 7 8 in 251 mm 6 1 2 in 165 mm 9 1 4 in 235 mm SLP45 45 Elbow SLP90 90 Elbow Effective Height Lengt...

Страница 76: ...eld trimmed If wall thickness is greater than 7 1 4 in 184 mm a DVP HSM B will be required Heat Shield Term Cap Minimum Effective Length Maximum Effective Length Trap1 3 1 8 in 4 3 4 in 79 mm 121mm Tr...

Страница 77: ...SS HORIZONTAL TERMINATION CAP When using DVP TB1 termination cap on top vented fireplaces a three foot minimum vertical vent section is required before installing first elbow 1 in 25 mm 14 in 356 mm...

Страница 78: ...___________________________ ________________________________________________________________________________ ________________________________________________________________________________ __________...