29
Heatilator • CNXT4236IT-D, CNXT4842IT-D, CNXT4236IH-D, CNXT4842IH-D • 2360-900 Rev. i • 5/17
INSTALLED
HORIZONTALLY
H
1
H
2
V
1
Figure 7.5
Two Elbows
Note:
For corner installations: A 6 inch
(152 mm) section of straight pipe may
need to be attached to the appliance
before a 90º
elbow, to allow the vent
pipe to clear the top standoffs.
CNXT4842 Series
V
1
Minimum
H
1
+ H
2
Maximum
Elbow only
Not allowed
1/2 ft.
152 mm
Not allowed
1 ft.
305 mm
2 ft.
610 mm
1-1/2 ft.
457 mm
2 ft.
610 mm
2 ft.
610 mm
4 ft.
1.2 m
2-1/2 ft.
762 mm
4 ft.
1.2 m
3 ft.
914 mm
6 ft.
1.8 m
4 ft.
1.2 m
10 ft.
3.1 m
6 ft.
1.9 m
14 ft.
4.3 m
8 ft.
2.4 m
18 ft.
5.5 m
10 ft.
3.1 m
20 ft.
6.1 m
V
1
+ H
1
+ H
2
= 40 ft. (12.2 m) Maximum
H
1
+ H
2
= 20 ft. (6.1 m) Maximum
V
1
= 1 ft. (305 mm) Minimum
CNXT4236 Series
V
1
Minimum
H
1
+ H
2
Maximum
Elbow only
Not allowed
1/2 ft.
152 mm
6 ft.
1.8 m
1 ft.
305 mm
11 ft.
3.4 m
1-1/2 ft.
457 mm
18 ft.
5.5 m
2 ft.
610 mm
25 ft.
7.6 m
V
1
+ H
1
+ H
2
= 40 ft. (12.2 m) Maximum
H
1
+ H
2
= 25 ft. (7.6 m) Maximum
V
1
= 1/2 ft. (152 mm) Minimum