34
Heatilator • Birmingham 42-B Installation Manual • 4059-715 • Rev P • 09/28/15
8
Fireplace Setup
A. Install Hearth Molded Brick Panel
• Place hearth panel into the fireplace.
B. Install Back Molded Brick Panel
• Remove screen rods.
• Remove smoke shield.
• Refer to Figure 8.1.
• Set the grate brackets in place, 26.5 in. (673 mm) center
to center.
• Install the back panel. Center from side to side.
• Install two refractory clips in the mortar lines across the
top. Tighten these and all previously installed brackets.
C. Install Side Molded Brick Panel
• If a gas line is to be installed, remove the knockouts in
the inner firebox and in the outer shell on the side of
your choice. Refer to dimension drawings for location of
knockouts and Section 8.I. for gas provisions.
• Install side panel, tapered edge to the front. Align the
front edge with the front of the column (or butted to the
surround if installed).
• Install two refractory clips in the mortar lines across the
top. Tighten these and all previously installed brackets.
• Install second side panel following the steps above.
• Replace smoke shield.
Figure 8.1 Traditional Molded Brick Panel
LH Traditional
Refractory
Back Traditional
Refractory
Hearth
Grate
Retainer
Refractory
Clips
LH Herringbone
Refractory
Back Herringbone
Refractory
Hearth
Grate
Retainer
Refractory
Clips
Figure 8.2 Herringbone Molded Brick Panel