Heatilator • ECO-WINS18 • 7065-132D • November 22, 2011
14
N. Blower Operating Instructions
1. The blower will turn on/off automatically when set to
AUTO.
Figure 14.1.
2. When set to MANUAL, the fan will turn on/off only when
you turn it on or off. This setting over-rides the internal
snap disc.
3. Blower Controls are located on bottom left of appliance.
M. Blower Control Box & Snap Disc
Operating Instructions
Figure 14.1
1.
Initial (cold) startup:
Raise
the Burn Rate Air Control
all the way up to the High setting.
The blower tends to
cool the appliance. Leave the blower off until the burn is
well established, i.e., 30 minutes.
2
. High Burn Setting:
Raise
the Burn Rate Air Control all
the way up to the High setting.
The blower may remain
on.
3.
Medium or Medium High Burn Setting:
Burn Rate Air
Control is closed then opened to 1 inch (pull up). The
blower may remain on.
4.
Medium
Low Burn Setting:
Burn Rate Air Control is
closed then opened to 1/4 inch to 1/2 inch (pull up).
Leave the blower
off for the fi rst 30 minutes until the burn
is well established.
5.
Low Burn Setting:
Burn Rate Air Control is closed
(down position). Leave the blower off for the fi rst 30 min-
utes until the burn is well established.
NOTE:
For maximum effi ciency and lowest emissions,
when operating the blower in either the automatic or
manual setting for the low and medium low burn settings
leave the blower off until the burn is well established, i.e.,
30 minutes,
When reloading the appliance, raise the Burn Rate Air
Control all the wall to the High setting for 5 to 15 minutes
before setting to the desired burn rate.
6. The blower is equipped with a rheostat (speed control).
The highest blower speed is obtained by turning the
rheostat on, then adjusting back towards “OFF” as far as
possible without turning the blower off. For a low blower
speed, turn the control knob clockwise as far as possible