background image

Page 3

598-1038-02

SPECIFICATIONS

Range . . . . . . . . . . . . . .  Up  to  70  ft.  (21  m);  100

ft.(30.5 m) with Range Boost.
[varies with surrounding
temperature]

Sensing Angle . . . . . . . .  Up to 240

°

Electrical Load . . . . . . . .  200 watt Incandescent (100

Max each lamp holder.)

Power Requirements . . .  120 VAC, 60 Hz
Operating Modes . . . . . .  TEST, AUTO and MANUAL

MODE

Time Delay . . . . . . . . . .  1 , 5, 20 minutes
Dual Brite™ Timer . . . . .  3, 6 hours, Dusk-to-Dawn
Replacement  lamp .  .  .  .  T4 100W, G8 halogen bi-pin

120 VAC

Heath

®

/Zenith reserves the right to discontinue prod-

ucts and to change specifications at any time without
incurring any obligation to incorporate new features in
products previously sold.

Loosen the clamp screw in
the sensor ball joint and gen-
tly rotate the sensor.

Walk through the coverage
area noting where you are
when the lights turn on. Move
the sensor head up, down, or
sideways to change the cov-
erage area. Keep the sen-
sor at least 2" (51 mm) away
from the lamps.

Adjust the RANGE as needed.
Too much range may increase
false triggering. Range Boost
increases coverage up to
100 feet.

Secure the sensor head's aim
by tightening the clamp screw.
Do not overtighten the
screw.

Set the amount of TIME you want the lights to stay
on after motion is detected (1, 5 or 20 minutes).

Set the DUAL BRITE™ switch to the amount of
time after dusk you want the lights on at low level
(Off, 3, 6 Hrs., Dusk-to-Dawn).

Clamp
Screw

Ball
Joint

Aim Sensor

Down for Short

Coverage

Aim Sensor

Higher for Long

Coverage

Maximum

Range

240

°

Maximum

Coverage Angle

Avoid aiming the sensor at:

Objects that change temperature rapidly, such as

heating vents and air conditioners. These heat
sources could cause false triggering.

Areas where pets or traffic may trigger the control.

Nearby large, light-colored objects reflecting

light may trigger the shut-off feature. Do not point
other lights at the sensor.

The control is most sensitive to motion across it.

Least Sensitive

Most Sensitive

Motion

Sensor

Motion

TEST AND ADJUSTMENT

Turn on the circuit breaker and light switch.

NOTE:

Sensor has a 

1

1

/

2

 minute warm up period

before it will detect motion. When first turned on
or when switching modes wait 

1

1

/

2

 minutes.

Bottom of Sensor

Turn the RANGE control to the mid position, Dual
Brite™ to OFF and the ON-TIME control to the
TEST position.

70 ft.

100 ft.

(21 m) (30.5 m)

Boosted

8 ft.

(2.4 m)

Содержание Dual Brite SL-5597

Страница 1: ...TEST and the Dual Brite switch OFF MANUAL MODE ON TIME TEST 1 5 20 back on AUTO 1 Second OFF then Put the ON TIME switch in the 1 5 or 20 minute position Dual Brite TIMER Light comes on half bright for selected time after dusk Off 3 hr 6 hr until dawn If motion is sensed the light turns on full bright for the ON TIME 1 5 or 20 minutes then returns to dim mode Move ON TIME Switch to 1 5 or 20 minut...

Страница 2: ...ack into the ball joint Tighten the clamp screw when done Mounting Strap Mounting Bolt White to White Black to Black Gasket Junction box ground wire to green ground screw on fixture Rubber Plug WIRE THE LIGHT CONTROL Turn power off at the fuse or circuit breaker Remove the existing light fixture Bulb installation NOTE When re lamping turn power off and let the fixture cool To remove lamp shade loo...

Страница 3: ...ytighteningtheclampscrew Do not overtighten the screw Set the amount of TIME you want the lights to stay on after motion is detected 1 5 or 20 minutes Set the DUAL BRITE switch to the amount of time after dusk you want the lights on at low level Off 3 6 Hrs Dusk to Dawn Clamp Screw Ball Joint Aim Sensor Down for Short Coverage Aim Sensor Higher for Long Coverage Maximum Range 240 Maximum Coverage ...

Страница 4: ...s positioned too close to the sensor or pointed at nearby objects that cause heat to trigger the sensor Reposition the lamp away from the sensor or nearby objects 2 Light Control is pointed toward a heat source like an air vent dryer vent or brightly painted heat reflective surface Reposition sensor Reduce Range 3 LightControlisinManualMode SwitchtoAuto 1 Heat or light from the lamps may be turnin...

Страница 5: ... luego Mueva el interruptor de tiempo ON TIME a 1 5 ó 20 minutos Apague el interruptor por un segundo y préndalo de nuevo ON TIME TEST 1 5 20 Ponga el interruptor de tiempo ON TIME en la posición de 1 5 ó 20 minutos Para AUTOMATICO Resumen de las modalidades del interruptor Ponga el interruptor detiempo ON TIME al fondo del detector en la posición de prueba TEST yDual Brite a apagado OFF Para PRUE...

Страница 6: ...ntaje Empuje el tapón de caucho firmemente hasta que encaje Sinoseusóunacajadeempalmeenunlugarhúmedo calafateelasuperficiedemontajedelaplacadelapared con un sellador de silicona contra la intemperie Instalación de bombilla Sieldetectorsesaledelauniónesférica aflojeeltornillo sujetador y empuje el detector hacia dentro de la unión esférica Apriete el tornillo sujetador cuando termine Cable de a tie...

Страница 7: ...llo de la grampa No ajuste demasiado el tornillo Fije el período de TIEMPO que la luz debe quedarse prendida cuando detecta movimiento Se lo puede calibrar de 1 5 ó 20 minutos Para una iluminación ornamental de baja intensidad pongaelinterruptordeDualBrite en la posición de 3 6 ó del Dusk to Dawn atardecer al amanecer Tornillo de la Grampa Unión Esférica Apunte el detec tor hacia abajo para una co...

Страница 8: ...erficie con pintura brillante y que refleja el calor Reposicione el detector 3 El control de luz está en la Modo Manual Cámbiela a Automática 1 El calor o la luz de las lámparas pueden estar prendiendo y apagando el Control de Luz Reposicione las lámparas lejos del detector 2 Elcalorquesereflejadeotrosobjetos pueden estar afectando al detector Reposicione el detector 3 El Control de Luz está en fa...

Страница 9: ... alimentation pendant une minute puis la rétablir Après le temps d étalonnage la commande reviendra au mode AUTO Placer l interrupteur de temps en dircuit ON TIME à la base du capteur à TEST et l interrupteur Dual Brite à OFF ON TIME Amener l interrupteur de temps en circuit ON TIME à la position correspondant à 1 5 ou 20 minutes TEST 1 5 20 TEST 1 5 20 ON TIME Off 3 6 Dusk to Dawn DUAL BRITE Minu...

Страница 10: ... intérieur de la boîte de jonction Aligner la vis de montage sur le centre du trou de la bride de mon tage Fixer l appareil à la bride de montage Poussez le bouchon de caoutchouc fermement en place Si une boîte de jonction pour endroit mouillé n a pas été utilisée calfeutrer la surface de montage de la plaque murale avec un scellant silicone d extérieur Abat jour Vis de blocage Installation de l a...

Страница 11: ... Pour une couverture accrue utiliserl amplificationdeportée Range Boost Fixerlatêtedudétecteurenposi tionenserrantlavisedeblocage Éviter de trop serrer la vis Placer l interrupteur ON TIME à 1 5 ou 20 minutes Réglerl interrupteurDualBrite autempsd allumage désiré àfaibleintensité aprèslecrépuscule 3h 6h crépuscule aurore Mouvement Le détecteur est moins sensible au mouvement dans sa direction Port...

Страница 12: ...jecteur se trouve trop près du détecteur de la commande d éclairage ou est pointé vers des objets tout près dont la chaleur déclenche le détecteur Éloigner le projecteur du détecteur ou des objets avoisinants 2 Ledétecteurdelacommanded éclairage pointe vers une source de chaleur comme un évent d aération un évent de sécheuse ou une surface peinte de couleur vive réfléchissant la chaleur Réorienter...

Отзывы: