5
598-1234-04
The detector is less sensitive to motion di-
rectly towards it and more sensitive to across
motion.
Sensor
Motion
Least Sensitive
Most Sensitive
Avoid aiming the control at:
• Objects that change temperature rapidly,
such as
heating vents and air condition-
ers.
These heat sources could cause false
triggering.
• Areas where
pets or traffic
may trigger
the control.
•
Nearby large, light-colored objects
reflecting light may trigger the shut-off
feature. Do not point other lights at the
sensor.
30 ft.
(9.1 m)
Maximum Range
Maximum
Coverage Angle
6 ft.
(1.8 m)
150°
COMPLETE THE
INSTALLATION
❒
Stuff the wires into the junction box. Make
sure none of the wires get pinched.
Slide the fixture onto the mounting
screws and tighten nuts.
❒
Install light bulb (100 Watt maximum).
❒
Install the lower glass assembly (if
applicable). Secure with decorative
screws.
❒
After completing the tests,
caulk between
fixture canopy and mounting surface
with silicone weather sealant.
Junction
Box
Motion
LOWER ARM INSTALLATION
(4294 Only)
Model 4294 comes with a separate lower
arm. Follow the directions below to attach
the lower arm.
1. Complete the in-
stallation steps
above.
2. Using the decora-
tive screws pro-
vided, secure the
lower arm to the
canopy and the
bottom of the low-
er glass assem-
bly as shown.
Canopy
Mounting
Surface
TESTING
❒
Turn on the circuit breaker and light
switch.
Note: Sensor has a 1
1
/
2
minute warm up pe-
riod before it will detect motion. When
first turned on, wait 1
1
/
2
minutes.
Note: Meets the ENERGY STAR
®
guidelines
when D
ual
B
rite
®
function is off.
❒
Switch the on-time to TEST position and
D
ual
B
rite
®
switch to the OFF position.
TEST
1 5 10 MIN
ON-TIME
OFF 3 6 DUSK TO
HOUR DAWN