4
598-1305-04
SPeCIFICatIOnS
Range ........................... Up to 70 ft. (21 m); [varies with
surrounding temperature]
sensing Angle .............. Up to 180°
Lamp ............................. 15 watt, 6 volt halogen
Battery Type .................. sealed lead acid, 6 V 6.0 A-Hr.
On Time ........................ TEsT (5 seconds), 1 or 5 min-
utes, OFF, selectable
Full Charge on Time ..... Up to 1 hour
thIngS tO reMeMBer
• Periodically clean the solar panel with a soft cloth and
warm water. Do not hose spray. Keep the collector clear
of snow and leaves. Make sure trees and other objects
do not block sunlight from the panel.
• If not to be used for several weeks, turn the unit OFF.
store it with the panel connected and where the panel
can gather sunlight.
• solar collection is only effective in direct sunlight. Every
hour the light is on requires a minimum of 16 hours of
sunlight charging. solar panels collect less than 10%
of the sun’s energy. Light bulbs convert this energy to
light at 5% efficiency.
• several days of use with overcast skies may discharge
the battery. Because of the battery protection circuit,
the light will not work until the battery is fully recharged.
Note:
To determine if the battery is charged after the
initial setup, watch the red LED on the front of the sensor.
If it blinks when motion is sensed, then the battery is
charged. If not, then turn the ON-TIME switch to off and
allow the sun to charge the battery for 3 to 7 days. Test
the battery as described under
Initial Battery Charge
,
page 1.
• This light is supplied with a 15 Watt, bi-pin, halogen
bulb. For replacement, use Heath
®
/Zenith model sL-
7000-A1-A or equivalent.
Note:
Using a larger bulb will
decrease battery life.
Battery rePLaCeMent
This solar light contains a rechargeable battery that
can be replaced if needed. Rechargeable batteries will
eventually lose their ability to hold a charge. To replace
the battery follow the steps below.
Battery Cover Catch Release
Battery
Cover
Positive Wire
Rechargeable
Battery
Negative Wire
Tab slots
HeathCo LLC reserves the right to discontinue products
and to change specifications at any time without incurring
any obligation to incorporate new features in products
previously sold.
IMPORTANT:
replace lamp only with same type lamp,
15 watts or less. DO nOt reverse the battery wires.
Damage to the unit will result. Like any lead-acid
battery, this battery must be disposed of properly.
IMPORTANT:
keep sensor switch in the “OFF”
position for 3 to 7 days to allow the battery to fully
charge before testing.
1. Remove rear battery cover. Press in the two catch
releases on the cover and remove the cover.
2. Remove rechargeable battery. slide battery out of case
and remove the wire connectors from the battery.
3. Replace battery. Connect the RED wire connector to
the positive (+) terminal and the BLACK wire connector
to the negative (-) terminal. Wire connectors should
fit tightly. If not, remove the wire connector from the
terminal. Use a pair of pliers to gently squeeze the
connector to ensure a tight fit. Reconnect wire con-
nector to the terminal.
4. Replace battery cover. Insert the two tabs on the cover
into the slots on the back of the case. Press the cover
against the case until the two catch releases snap into
place.
IMPORTANT:
the sealed lead-acid battery must be
recycled or disposed of properly.