Part # 25000102

Installation and Operations Manual

AC&R

Model

No.

Connection

Size

Operation

Pressure

Diff., psig

Oil Level,

Sight Glass

S-9010

3 BOLT

5 - 30

1/2

S-9010A

4 BOLT

5 - 30

1/2

S-9015

3/4” NPTF F.

5 - 30

1/2

S-9090

3 BOLT

5 - 90

Adjustable

S-9090A

4 BOLT

5 - 90

Adjustable

S-9110

3 BOLT

5 - 30

1/2

S-9120

3 BOLT

5 - 30

1/4 +

S-9130

3 BOLT

5 - 90

Adjustable

S-9190

3 BOLT

30 - 90

Adjustable

Sporlan

Model

No. Of

Cores

Desiccant

Volume

(cu. in.)

# Core

Part No.

C-489-(G)

1

48

RC-4864

RC-4864-HH

RCW-48

C-969-(G)

2

96

C14411-(G)

3

144

C-19211-(G)

4

192

C-4021-(G)

4

192

C-4025-(G)

4

192

Troubleshooting Oil System

The oil return line should always be checked. Feeling the oil 

return line and seeing how often it gets hot is the main way to 

tell if the separator is working properly. It is easier if an oil line 

sight glass is installed, mainly because if the oil line is hot you 

don’t know if it is oil or hot gas causing it to be hot. If the oil 

line cycles between hot and cold at least a few times per hour, 

the separator is most likely working properly. The float tends to 

open and feed a few ounces of oil at a time and shut until the 

oil builds back up. If the oil return is cycling there is no need to 

drain the separator to look at the float components.
Always check the oil reservoir level during a service call. Oil 

levels in the reservoir will normally vary during periods of 

varying loads: compressors shutdown, hot-gas defrost, etc. This 

is normal, however if the level is consistently low or high, the 

oil system should be checked thoroughly.
Compressor oil levels can be deceiving. It is sometimes hard 

to tell if the regulator is feeding oil or if oil is coming down the 

suction line. If the reservoir has too much pressure, often times 

this pressure will force oil out of the regulator and show a low 

level, even though there may be excessive oil in the compressor. 

Many times the best way to check the oil in the compressor is to 

shut off the oil feeding to the regulator while the compressor 

is operating and wait a few minutes. If oil is pushed out of the 

regulator or trapped in the motor cavity on semi-hermetic 

models, the compressor will overfill.
The oil line sight glass is a good way to see how the separator is 

working. Look for movement in the glass. If the separator is not 

feeding on single or low pressure systems, the sight glass will 

have little or no movement and normally will appear empty. If 

the separator is feeding, the sight glass will show a rush of oil 

and foam past the glass. Most of the time, viewing this sight 

glass can prevent having to open the system.
To check the oil level in the separator if the separator has a drain, 

shut off the oil return line to prevent further feeding, pump 

down the system, shut off the system, evacuate the separator, 

and drain the oil from the bottom.
The separator should hold the pre-charge amount plus or minus 

a few  ounces during operation. By looking at the amount above 

or below the pre-charge, any problem with the separator or 

float can be determined.
Note that there is no way to clean or repair welded oil separators. 

If  it  is  determined  that  the  float  is  clogged  or  otherwise 

malfunctioning, the entire oil separator must be replaced.

When the refrigerant and/or oil types are changed in a system, 

there  is  the  potential  for  leaks  around  o-ring  seals.  Most 

elastomers absorb oil and refrigerant and may swell or shrink 

when exposed to a new oil or refrigerant. In these cases replace 

the o-rings and seals in the system as needed.

Liquid Filter-Driers & Suction Filters

A replaceable core liquid filter/drier is supplied as standard 

on all Rack units and is an option in all other parallel systems. 

A Schrader type access valve is installed in the flange plate of 

some models. The liquid cores are always shipped loose for 

field installation. (See No. 5 of Leak Checking, Evacuation,  and 

Start-up section in this manual).

Table 22. AC&R Model Regulators

Table 23. Sporlan Valve Co.

Table 24. Alco Controls

“G” indicates flange plate supplied with _” FPT

#  “RC__” Standard Core, “RC__HH” Burnout Core

 “RCW_” High Water Capacity

* “T” indicates Liquid Line Service

#  “D” Standard Capacity, “H” High Capacity

 ”UK” High Capacity, “W” Burnout Block

Alco

Model

No. Of

Cores

Desiccant

Volume

(cu. in.)

# Core

Part No.

STAS-489-T*

1

48

D-48

H-48

UK-48

W-48

STAS-969-T

2

96

STAS-14411-T

3

144

STAS-19211-T

4

192

STAS-19213-T

4

192

STAS-19217-T

4

192

Содержание H-IM-PCS

Страница 1: ...Parallel Compressor Systems Bulletin No H IM PCS October 2004 Part Number 25000102 Replaces H IM 72B October 2004 Installation and Operation Manual...

Страница 2: ...peland Lubricants Carlyle Compressors Approved Carlyle Lubricants Oil Pressure Table 13 O6D E Oil Pressure History Table 14 Oil Safety Switch 22 Table 15 Part Load Performance Multipliers Table 16 Req...

Страница 3: ...tive and the carrier of the damage immediately Request an immediate joint inspection with the carrier Do not repair the unit until inspected by carrier s representative Care should be exercised when u...

Страница 4: ...es at the rear and 42 inches in the front of panel or as required by National or Local Codes For parallel system units placed end to end 24 inches between units is suggested Floor Foundation Requireme...

Страница 5: ...e ground level provides some protection from ground water and wind blown matter The concrete slab should be isolated from the building structure Finally before tightening mounting bolts recheck the le...

Страница 6: ...whenever possible Care should be taken to see that ample room is left for maintenance work through access doors and panels When the unit is in an area where it is enclosed by three walls the unit mus...

Страница 7: ...ment Before starting up a parallel unit insure that all fuses and motor protective devices are in place and that all wiring is secure A complete wiring diagram for troubleshooting the unit will be fou...

Страница 8: ...ed a maximum of 2 feet in each direction Pipingattachedtoavibratingobject suchasacompressor or compressor base must be supported in such a manner that will not restrict the movement of the vibrating o...

Страница 9: ...ially on hot gas lines to prevent line breakage This is critical on long straight runs of generally 70 or more where expansion loops must be provided and hangers should allow for longitudinal movement...

Страница 10: ...04A R 507 4 1 1 1 6 1 1 6 8 2 2 1 10 2 2 7 12 2 3 3 16 3 4 1 20 4 5 6 30 6 8 3 40 8 11 8 Table 2 Pressure Loss of Liquid Refrigerants In Liquid Line Risers Expressed in Pressure Drop PSIG and Subcooli...

Страница 11: ...2 57 3 50 4 98 14 27 40 26 42 58 40 64 95 61 93 1 32 1 91 1 33 1 87 1 5 8 12 134A 22 R 507 502 404A 90 9 90 0 78 0 3 65 4 96 7 07 20 37 56 37 59 82 57 90 1 35 87 1 33 1 86 1 30 1 88 2 64 2 1 8 12 134...

Страница 12: ...8 2 1 8 1 3 8 1 3 8 1 5 8 1 5 8 1 5 8 2 1 8 1 3 8 1 5 8 1 5 8 1 5 8 1 5 8 2 1 8 1 5 8 1 5 8 1 5 8 84 000 1 1 8 1 3 8 1 5 8 1 5 8 1 5 8 2 1 8 1 3 8 1 3 8 1 5 8 1 5 8 2 1 8 2 1 8 1 3 8 1 5 8 1 5 8 1 5 8...

Страница 13: ...8 5 8 5 8 72 000 1 5 8 2 1 8 2 1 8 1 5 8 1 5 8 1 5 8 1 5 8 2 1 8 2 1 8 1 5 8 1 5 8 1 5 8 1 5 8 2 1 8 2 1 8 5 8 5 8 5 8 5 8 5 8 7 8 78 000 2 1 8 2 1 8 2 1 8 1 5 8 1 5 8 1 5 8 2 1 8 2 1 8 2 1 8 1 5 8 1...

Страница 14: ...1 5 8 1 5 8 1 1 8 1 3 8 1 5 8 1 5 8 1 5 8 2 1 8 1 3 8 1 3 8 1 5 8 84 000 1 1 8 1 1 8 1 3 8 1 3 8 1 3 8 1 5 8 1 1 8 1 3 8 1 3 8 1 3 8 1 5 8 1 5 8 1 3 8 1 3 8 1 5 8 1 5 8 1 5 8 2 1 8 1 3 8 1 5 8 1 5 8...

Страница 15: ...5 8 5 8 72 000 1 5 8 2 1 8 2 1 8 1 3 8 1 5 8 1 5 8 1 5 8 2 1 8 2 1 8 1 3 8 1 5 8 1 5 8 2 1 8 2 1 8 2 1 8 1 2 1 2 5 8 5 8 5 8 7 8 78 000 1 5 8 2 1 8 2 1 8 1 3 8 1 5 8 1 5 8 2 1 8 2 1 8 2 1 8 1 3 8 1 5...

Страница 16: ...1 8 1 3 8 1 1 8 1 1 8 180 000 50 100 1 5 8 2 1 8 1 3 8 1 3 8 1 3 8 1 3 8 1 3 8 1 3 8 1 3 8 1 5 8 1 3 8 1 3 8 1 3 8 1 5 8 1 3 8 1 3 8 240 000 50 100 1 5 8 2 1 8 1 5 8 1 5 8 1 5 8 1 5 8 1 3 8 1 3 8 1 5...

Страница 17: ...e pull down The wiring diagramfortheunitwillhavetobeconsultedtodetermine how to best force the fans to operate for this step 4 With all compressor and control breakers and toggle switches turned off a...

Страница 18: ...eturned into the liquid manifold the Priority I design returns the liquid to the condenser through a liquid drain manifold Hot discharge gas is injected into the suction line at the parallel rack and...

Страница 19: ...igerant being returned to the compressor This will cause dilution of the oil and eventual failure of the bearings and piston rings In extreme cases the compressor will fail as a result of the diluted...

Страница 20: ...est The compressors are solid mounted to a base frame or mounted on the refrigerant receiver All reciprocating compressors incorporate oil floats Crankcase heaters will be installed and wired Cylinder...

Страница 21: ...1 24 to 1 8 18 to 34 1 24 to 2 3 Carlyle Compressors Approved Carlyle Lubricants For CFC and HCFC Refrigerants Use Totaline 150 Suniso 3GS Shrieve Zerol 150 Texaco WFI 32 150 IGI Petroleum Cryol 150...

Страница 22: ...eactivated after a specified trip delay The output relay reactivates after power line conditions return to an acceptable level for a specified amount of time Restart Delay The trip delay prevents nuis...

Страница 23: ...Vessel is exposed to excessive heat When a Vessel containing liquid refrigerant is shut off from otherpartsofthesystemariseintemperaturewillcausearisein pressure If theVessel is completely filled wit...

Страница 24: ...let 350 400 425 450 Angle 526E 3 8 MPT 3 8 FLARE 10 2 11 6 12 3 13 0 527E 1 2 MPT 5 8 FLARE 28 5 32 4 34 4 36 3 Straight Through 5231 3 8 MPT 3 8 FLARE 11 2 12 7 13 5 14 3 5231 A 3 8 MPT 1 2 FLARE 18...

Страница 25: ...cannot be reset until the pressure drops to a predetermined level The latching mechanism inside the manual reset model is trip free The electrical contacts will cutout even if the reset button is hel...

Страница 26: ...d to insure the system will work properly Low Pressure Oil System This type system is normally used for parallel compressors and uses three basic components Oil Separator Oil Reservoir and Oil Level R...

Страница 27: ...pressure expansion valve with a range of 0 to 90 psig Temprite Part No is 67070000 An alternative valve manufactured by Sporlan is Model ADRI 11 4 0 90 Oil Level Regulators The AC R adjustable oil re...

Страница 28: ...n the motor cavity on semi hermetic models the compressor will overfill The oil line sight glass is a good way to see how the separator is working Look for movement in the glass If the separator is no...

Страница 29: ...strainers and filter driers 3 Install a replacement compressor and make a complete electrical check 4 Make sure the suction line adjacent to the compressor is clean Install a liquid line filter drier...

Страница 30: ...r pressure The regulator closes as the condenser pressure drops below the set point thus back flooding the condenser and reducing the inside surface area available for condensing Valve B is and Outlet...

Страница 31: ...utdoor temperature to allow the system pressures to drop below the regulator pressure settings Before adjusting make sure that all manual opening stems on the regulators are set for automatic operatio...

Страница 32: ...0psig withonecompleteturnequal toapproximately4psichange Adjustmentsshouldbemade insmallincrements allowingforthesystemtostabilizeafter each turn 6 Vary the evaporator load to test at various conditio...

Страница 33: ...connections Checkoperationandconditionofcontactsoncompressor fan motor contactors Check appearance of control panel interior Check appearance of exterior conduit junction boxes Check appearance of ins...

Страница 34: ...tor Check stator If leads are all right replace stator Eliminate cause of excessive pressure Check oil level Correct binding Unit Operates Long Or Continuously 1 2 3 4 5 6 Control contacts sticking in...

Страница 35: ...ters Check and reset for proper superheat Check means for regulating condensing temperature Check for proper sizing Little or No Oil Pressure 1 2 3 4 5 6 7 8 9 Clogged suction oil strainer Excessive l...

Страница 36: ..._ Group __________________ Group _________________ Compressor Model Serial No __________________ __________________ Group __________________ Compressor Model Serial No __________________ _____________...

Отзывы: