Electrical Safety and Installation Warnings

 

 

 

Extension cords may be used if care is exercised in their use. If 

an extension cord is used: 

  The marked electrical rating of the cord set or extension cord should be at least as great as the electrical 

rating of the appliance. 

  The cord should be arranged so that it will not touch hot surfaces, sharp edges or drape over the 

countertop or tabletop (where it can be pulled or tripped over unintentionally). 

Outdoor  extension  cords  should  be  used  with  products  suited  for  outdoor  use.  They  are  surface  marked  with 

suffix letters "W" or "W-A" and with a tag stating "Suitable for Use with Outdoor Appliances". 

To protect against electrical shock, the power cord and plug should be kept dry and off of the ground. Do 

not clean this product with water spray; do not spray cleaners into the lamp socket area. 

Gasoline, lighter fluid or other flammable liquids and vapors should never be stored in the area of this  appliance 

or any other appliance. 

Before installation or service, disconnect the power supply to the work area by removing the fuse, "tripping" the 

circuit breaker, or unplugging the unit. 

Keep any electrical supply cord and fuel supply hose away from any heated surfaces, sharp edges and 

dripping grease. 

Be certain your appliance is properly installed and grounded by a qualified technician in accordance with 

applicable codes. To guarantee the electrical safety of this appliance, continuity must exist between the 

appliance and an effective grounding system. It is imperative that this basic safety requirement be met. The 

manufacturer cannot be held responsible for damages caused by the lack or inadequacy of an effective 

grounding system. 

Do not operate any appliance with a damaged power cord or power plug, and do not operate any appliance 

after the appliance malfunctions or has been damaged in any manner. If this should occur, return the appliance 

to  the nearest authorized service facility for examination, repair or adjustment. 

Be certain your appliance is properly installed and grounded by a qualified technician in accordance  with 

applicable codes. To  guarantee the electrical safety of this appliance, continuity must exist between  the 

appliance  and  an  effective  grounding  system.  It  is  imperative  that  this  basic  safety  requirement  be  met. 

The manufacturer cannot be held responsible for damages caused by the lack or inadequacy of an  effective 

grounding system. 

This  appliance  conforms  to  all  uniform  electrical  safety  codes  and  electrical  grounding  regulations.  Install 

unit  according  to  I.A.W.  local  codes  or  with  National  Electrical  Code ANSI/NFPA 70  or  CSA C22.1  in  their 

absence. 

 

Содержание HTS-325

Страница 1: ...stomerService Heat OutdoorLiving com www Heat OutdoorLiving com DANGER IF YOU SMELL GAS I Shut off the gas supply to the appliance at its source 2 Extinguish any open flames 3 Open grill hood to relea...

Страница 2: ...17 i Checking for Gas Leaks 17 19 ii Unpacking Unit 20 V Gas Connections 21 i Natural Gas Requirements 21 ii Liquid Propane Gas and TankRequirements 21 iii Transporting and Storing LP Gas 22 23 VI In...

Страница 3: ...o Replace Conventional Burner with Infrared Sear Burner 35 ii Preheating the Infrared Burner 35 iii Infrared Burner Cleaning 35 X Fuel Conversion 36 i Gas Regulator 36 37 ii Main Burner 38 iii Rear Bu...

Страница 4: ...Heat Zone Separators 1 Year all other components Appliances must be registered within 30 days of purchase to validate this warranty See warranty section for details Model HTS 432 NG HTS 432 LP 4 BURNE...

Страница 5: ...mer Flame Stabilizer Grid Zone Cooking Removable Heat Zone Separators Rotisserie Kit Motor Forks Optional Burner Commercial Quality Cast Stainless Steel Gas Type Each grill contains an NG LP Conversio...

Страница 6: ...HEAT Instructional Book Page 6 Version 1 0 BBQ SPECIFICATIONS NOTE ALWAYS have equipment measured by Contractor before beginning any project 3 Burner...

Страница 7: ...HEAT Instructional Book Page 7 Version 1 0 4 Burner...

Страница 8: ...HEAT Instructional Book Page 8 Version 1 0 5 Burner...

Страница 9: ...ed service agent NOTE This appliance is not intended for commercial use FOR YOUR SAFETY If you smell gas 1 Shut off gas to the appliance 2 Extinguish any open flame 3 If odor continues immediately cal...

Страница 10: ...ual gas valve must be installed in the gas supply line to this appliance This applies to permanently installed natural gas and propane installations This does not apply to propane portable installatio...

Страница 11: ...urner tube shutter hole securely over the valve orifice and ensuring the male post on the rear of the burner rests in the opening in the grill chassis Failure to do so could result in a fire and injur...

Страница 12: ...t approved to be installed in or on any recreational vehicles and or boats HEAT Grills are for single family residential use only When determining a suitable location take into account concerns such a...

Страница 13: ...surface This appliance is not designedfor recreational vehicles and should not be installed on a boat or marine craft Protection from Weather Keep the appliance protected from adverse weather includin...

Страница 14: ...appliance is turned on To prevent injuries do not use accessories that are not recommended by the manufacturer Before cleaning the appliance disconnect the rotisserie and trip the circuit breaker Neve...

Страница 15: ...ated surfaces sharp edges and dripping grease Be certain your appliance is properly installed and grounded by a qualified technician in accordance with applicable codes To guarantee the electrical saf...

Страница 16: ...gas supplied to the appliance conforms to the model you purchased A Natural Gas appliance requires natural gas to operate an LP appliance requires liquid propane gas to operate Never connect the appl...

Страница 17: ...in Canada must be in accordance with the standard CAN CGA B149 2 Propane Installation Code A licensed contractor or local gas company representative must perform all natural gas connections Ensure tha...

Страница 18: ...testing solution by spraying it on joints of the gas delivery system This includes all valves pipe connections joints lines and every point from the gas source to the burners Blowing bubbles in the s...

Страница 19: ...re all control valves are in the off position This can create a low flow of gas through the grill This would require the tank to be disconnected from the regulator and then reconnected to reset the re...

Страница 20: ...p We do however recommend the use of professional help during the installation of your unit as improper installation may affect your warranty Remove the unit from the box along with all accessories an...

Страница 21: ...st be installed in an accessible place Liquid Propane LP Gas and Tank Requirement If your HEAT Grill is for a Liquid Propane application an LP regulator set for 11 WC must be used and is for use with...

Страница 22: ...ened to prevent leakage Always check for leaks before every use If one is not already available it is recommended that an ON OFF shutoff valve be installed at the gas supply source and that the gas su...

Страница 23: ...tighten the regulator 5 Check for leaks using a soapy water solution by spraying on all connections including all of the valves fittings lines etc any and all gas connections have the ability leak an...

Страница 24: ...uld combustible materials such as a combustible wall be located behind the grill that the needed 5 for lid clearance doesn t satisfy the distance required from a combustible surface Protection from We...

Страница 25: ...able from your dealer to cover the island venting The following information is important to consider when adhering to your local code requirements LP Propane Gas LP gas is heavier than air and will se...

Страница 26: ...tioned lower on the island cavity for LP gas ALL GAS CONNECTION POINTS SHOULD BE TESTED FOR LEAKS AFTER INSTALLATION PRIOR TO FIRST USE OF THE GAS APPLIANCE S Before installing an appliance in any isl...

Страница 27: ...nding slot in the grill chassis Failure to do so could result in a fire and injury If the outdoor kitchen countertop will overhang the face of the island notching out the two front countertop edges wi...

Страница 28: ...non combustible materials If your outdoor kitchen is constructed of combustible materials an insulated jacket is REQUIRED ALL BBQ ISLANDS MUST BE MANUFACTURED FROM NON COMBUSTIBLE MATERIAL Maintain mi...

Страница 29: ...HEAT Instructional Book Page 29 Version 1 0 Installation Diagram 5 Gallon LP tank shown Installation Method for Low Pressure Gas Source Natural Gas Regulator shown...

Страница 30: ...ined All packaging has been removed All parts and components are properly in place An installer supplied manual gas shut off valve is fully accessible LP hose is clean and inspected for cuts wear abra...

Страница 31: ...d consult an authorized service technician 7 Upon successful lighting repeat the process on the other burners you wish to light 8 To shut off the burners rotate the knob and turn to OFF It is normal t...

Страница 32: ...may have a tint of yellow and adjustment to the air shutters can be made to obtain a blue flameand proper gas glow see flame adjustment This appliance should be preheated before cooking with the main...

Страница 33: ...e the burner from the appliance and loosen the phillips head screw holding the air shutter to the burner If the flame is yellow open the air shutter to make the flame bluer If the flame is lifting off...

Страница 34: ...th the hood closed This allows any food particles or grease drippings to burn away Brush components with a stainless steel bristle brush to remove any remaining charred materials Cast Stainless Steel...

Страница 35: ...with the flamer tamer reinstalled above the burner Note It is critical that the end of the infrared burner is installed appropriately onto the gas valve to ensure gas flows safely into the burner For...

Страница 36: ...d from a larger tank permanently installed on location the regulator included with the appliance will only need to be converted for use with LP fuel see NG LP Regulator Conversion below Please be awar...

Страница 37: ...HEAT Instructional Book Page 37 Version 1 0...

Страница 38: ...ing and have to replace the valve 7 Once the old orifice is removed replace it with the new orifice repeat for all burners When re installing the orifice do not over tighten or you will strip the bras...

Страница 39: ...ny implied warranty for incidental or consequential damages and HEAT liability is limited to the purchase price of the appliance only This warranty gives you specific legal rights and you may also hav...

Страница 40: ...Burner XLS 40 041 5 Burner Drip Tray XLS 40 022 Rotis Valve XLS 32 029 Electrode Wire Rear Burner XLS 32 042 Stainless Steel Flame Tamer XLS 32 064 Flashtube XLS 32 058 Stainless Steel Flex line XLS...

Страница 41: ...HEAT Instructional Book Page 41 Version 1 0 HEAT 4 5 Burner Note Add one burner one flame tamer one heat separator and one grid for the HEAT 5 Burner...

Страница 42: ...of the Firebox see picture on page 12 You will need this number to properly register your appliance and activate coverage Write this information in the space provided below for your records Appliance...

Страница 43: ...ready if you ever need warranty help Name First Last Email Phone Street Address Address Line 2 City State Province Region Zip Postal Code Country What is the model number of the HEAT Product purchase...