5
Appliance and Location
Appliance and Location
The appliance is for outdoor use only.
Do not use indoors or in an enclosed area .
Always maintain proper clearance from combustible materials
- minimum 800mm from the top of the unit, and a minimum of
650mm from sides .
Leakage Test
Gas connections on the appliance are leak tested prior to shipment . Possible mishandling
of the appliance during shipment can damage the integrity of some parts .
A complete gas leakage test must be performed again at the installation site . Please
follow the procedure below for leakage test .
1 . It is advised to make a soap / liquid detergent and water solution to identify any
holes/splits or loose fittings in the tube.
2 . Make sure the control tap is in the OFF position (full disk = • ) on the control panel.
3 . Apply the solution to the hose using a brush or rag .
4 . Turn ON the gas supply and check for bubbles from the hose . If the air bubbles
appear this indicates a leak in the hose .
5 . If a leak is present, turn OFF the gas supply immediately, tighten any leaking fitting
carefully, turn gas again and recheck .