Step 11.  Before Lighting  the Fireplace

Before

 lighting the fireplace, be sure to do the following:

!

!

Step 12.  Lighting the Fireplace

You’ve reviewed all safety warnings, you’ve checked the
fireplace for gas leaks, you know the vent system is
unobstructed, and you’ve checked for faulty components.
Now you’re ready to light the fireplace.

WARNING: PLEASE REFER TO THE USER’S
MANUAL  FOR  ALL CAUTIONS, SAFETY,

AND WARNING INFORMATION PERTAINING TO
THE LIGHTING  AND OPERATION OF THE
FIREPLACE.

After the Installation

LEAVE THIS INSTALLATION MANUAL WITH
THE  APPLIANCE FOR FUTURE REFERENCE.

During this break-in period it is recommended that some
windows in the house be opened for air circulation. This
will help avoid setting off smoke detectors, and help elimi-
nate any odors associated with the fireplace’s initial burning.

Remove all paperwork from underneath the fireplace.

Review safety warnings and cautions

• Read the 

Safety and Warning Information

 section at

the beginning of this 

Installers Guide

.

Double-check for gas leaks

Before lighting the fireplace, double-check the unit for
possible gas leaks.

Double-check vent terminations and front grilles for
obstructions.

• Before lighting the fireplace, double-check the unit for

possible obstructions that could be blocking the vent
terminations or the front grilles.

Double-check for faulty components

• Any component that is found to be faulty 

MUST BE

 re-

placed with an approved component. Tampering with
the fireplace components is 

DANGEROUS

 and voids

all warranties.

A small amount of air will be in the gas supply lines. When
first lighting the fireplace, it will take a few minutes for the
lines to purge themselves of this air. Once the purging is
complete, the fireplace will light and will operate normally.

Subsequent lightings of the fireplace will not require this
purging of air from the gas supply lines,

 unless

 

the gas

valve has been turned to the OFF position

, in which

case the air would have to be purged.

NOTE:

 The fireplace should be run 3 to 4 hours on the

initial start-up. Turn it off and let it cool completely. Remove
and clean the glass. Replace the glass and run the fireplace
for an additional 8 hours. This will help to cure the products
used in the paint and logs.

• Remove the rubber bands from the log set (see Figure

36).

Figure 36.

RUBBER

BANDS

FOAM

PADS

• Remove the two foam pads which support the log set

and grate and allow the log set and grate to rest on the
base pan.

• Install the Lava Rock (supplied) to the firebox base pan

being careful not to cover the burner with the Lava Rock.

Содержание Pier-PV-IPI

Страница 1: ...E REFERENCE 1 This appliance may be installed in an af termarket permanently located manu factured mobile home where not pro hibited by local codes 2 This appliance is only for use with the type of ga...

Страница 2: ...ERSTAND all instructions carefully before starting the installation FAILURE TO FOLLOW these installation instructions may result in a possible fire hazard and will void the warranty Prior to the first...

Страница 3: ...19 Step 4 Positioning Leveling and Securing the Fireplace 22 Step 5 The Gas Control System 22 Step 6 The Gas Supply Line 23 Step 7 Gas Pressure Requirements 23 Step 8 Wiring the Fireplace 24 Step 9 F...

Страница 4: ...riate to the particular installation Refer to the National Fuel Gas Code ANSI Z223 1 NFPA54 current edition The Uniform Mechanical Code current edition and local Building Officials for the options all...

Страница 5: ...ructions will void the own er s warranty and may present a fire hazard The Heat N Glo Warranty will be voided by and Heat N Glo disclaims any responsibility for the following actions Installation of a...

Страница 6: ...DOOR TOP STANDOFFS 1 2 13mm 2 43 5 8 1107mm 42 5 8 1081mm 42 1067mm 32 3 4 829mm 21 533mm 32 5 16 820mm 8 1 2 216mm 37 7 16 950mm 17 15 16 455mm 24 610mm 21 533mm 12 304mm 2 ELECTRICAL ACCESS 4 100mm...

Страница 7: ...mm 8 1 2 216mm 24 610mm 2 9 16 64mm 4 1 2 114mm 47 5 8 1208mm 32 3 4 829mm 12 304mm 2 4 100mm 2 ELECTRICAL ACCESS GAS LINE ACCESS 26 5 8 676mm 10 1 2 266mm 4 1 16 102mm 2 4 1 2 114mm 2 4 3 4 121mm 2 5...

Страница 8: ...or after the fireplace is set in place Framing should be positioned to accommo date wall coverings and fireplace facing material The dia gram below shows framing reference dimensions CAUTION MEASURE F...

Страница 9: ...er or heavier Model A B C D PIER PV IPI 42 1 8 42 1 2 23 25 5 8 ST PV IPI 47 5 8 42 1 2 23 26 5 8 Figure 4 Framing Dimensions NOTE DIMENSIONS SHOWN IN INCHES Showscenterof 12 x 12 vent framing holes f...

Страница 10: ...r horizontal vent runs NO OTHER VENTING SYS TEMS OR COMPONENTS MAY BE USED Detailed installation instructions are included with each vent termination kit and should be used in conjunction with this In...

Страница 11: ...IGHT OUT HORIZONTAL VENTING H FT 36 MIN 914 mm 40 MAX 12 2 M 8 900 Bends MAX Figure 7 STRAIGHT UP VERTICAL VENTING V FT 40 MAX 12 2 M 8 900 Bends MAX Figure 8 V H VERTICAL DROP V MAX Run 48 1219 mm 8...

Страница 12: ...as fireplaces to draft properly If the home experiences negative pressure or is likely to experience negative pressure connection to an outside air source is mandatory A 4 inch side collar see Figure...

Страница 13: ...ing 9 9 INTERIOR WALL SHIELD FLEX PIPE For Vertical Runs One ceiling firestop is REQUIRED at the hole in each ceiling through which the vent passes To install firestops for vertical runs that pass thr...

Страница 14: ...4 REQUIRED NOTE There must be NO INSULATION or other combustibles inside the framed firestop opening WARNING VENTING TERMINALS SHALL NOT BE RECESSED INTO A WALL OR SIDING VENT TERMINATION CLEARANCES...

Страница 15: ...ensions specified for vinyl or non vinyl siding and soffits 1 There must be 3 feet minimum between termination caps 2 All mechanical air intakes within 10 feet of a termination cap must be a minimum o...

Страница 16: ...AGRAM FOR MINIMUM HEIGHTS PROVIDED THE TERMINA TION CAP IS AT LEAST 20 INCHES FROM A VER TICAL WALL AND 2 FEET BELOW A HORIZONTAL OVERHANG NOTE This also pertains to vertical vent systems in stalled o...

Страница 17: ...t to the floor The diagram below shows how to properly position level and secure the fireplace Figure 22 Proper Positioning Leveling and Securing of a Fireplace Step 5 The Gas Control System WARNING T...

Страница 18: ...t does not penetrate the actual firebox Open the fireplace lower grille insert the gas supply line through the gas line hole and connect it to the shut off valve When attaching the pipe support the co...

Страница 19: ...WHT ORG GRN WHT ON OFF WALLSWITCH BRN BRN BLK WHT BLK WHT BLK WHT BLK TERMINAL BLOCK BULB SOCKET ASSEMBLY 3 ROCKER SWITCH BLK OPTIONAL ELECTRIC EMBER KIT EMBERKIT MS RED BRN BLK BL K WHT RED BRN BLK W...

Страница 20: ...Figures 27 Figure 26 Fan Wiring Diagram Optional Accessories Optional fan and remote control kits require that 110 120 VAC be wired to the factory installed junction box before the fireplace is perman...

Страница 21: ...stible material such as wood can be placed on the top edge and sides of the fireplace Hearth Extensions A hearth extension may be desirable for aesthetic reasons However ANSI or CAN CGA testing standa...

Страница 22: ...el Type PIER PV IPI TEMPERED ST PV IPI TEMPERED Heat N Glo fireplaces manufactured with tempered glass may be installed in hazardous locations such as bathtub enclosures as defined by the CPSC The tem...

Страница 23: ...rts at the rear of the burner Save the remaining ember materials for use during fire place servicing The bag of embers provided is suffi cient for 3 to 5 applications Replace the glass door and a fron...

Страница 24: ...ghting the fireplace double check the unit for possible obstructions that could be blocking the vent terminations or the front grilles Double check for faulty components Any component that is found to...

Страница 25: ...eriodically By Qualified service technician Task Make a visual check of the straight flame sensor rod Use emery cloth to carefully remove any existing film or white deposits Checking Flame Patterns Fl...