• Insert insulation from the outside of the fireplace and

pack the insulation tightly to totally seal between the
pipe and the outer casing.

• At the gas line access hole the gap between the supply

piping and gas access hole can be plugged with non-
combustible insulation to prevent cold air infiltration.

Step 6.  The Gas Supply Line

NOTE: Have the gas supply line installed in accordance
with  local  building codes by a qualified installer
approved and/or licensed as required by the locality.
(In the Commonwealth of Massachusetts installation
must be performed by a licensed plumber or gas
fitter).

NOTE: Before the first firing of the fireplace, the gas
supply line should be purged of any trapped air.

NOTE: Consult local building codes to properly size
the gas supply line leading to the 1/2 inch
(13 mm) hook-up at the unit.

This gas fireplace is designed to accept a 1/2 inch
(13 mm) gas supply line. To install the gas supply line:

• A listed (and Commonwealth of Massachusetts approved)

1/2 inch (13mm) tee-handle manual shut-off valve and a
listed  flexible gas connector are connected to the 1/2
inch (13mm) inlet of the control valve. 

NOTE:

 If substi-

tuting for these components, please consult local codes
for compliance.

• Locate the gas line access hole in the outer casing of

the fireplace.

• The gas line may be run from either side of the fireplace

provided the hole in the outer wrap does not exceed 2” in
diameter and it does not penetrate the actual firebox.

• Open the fireplace lower grille, insert the gas supply line

through the gas line hole, and connect it to the shut-off
valve.

• When attaching the pipe, support the control so that the

lines are not bent or torn.

• After the gas line installation is complete, all connec-

tions must be tightened and checked for leaks with a
commercially available, non-corrosive leak check solu-
tion. Be sure to rinse off all leak check solution following
testing.

WARNING: DO NOT USE AN OPEN FLAME
TO CHECK FOR GAS LEAKS

.

!

Step 7.  Gas Pressure Requirements

Pressure requirements for Heat-N-Glo gas fireplaces
are shown in the table below.

Pressure

Natural Gas

Propane

Minimum

5.0 inches

11.0 inches

Inlet Pressure

w.c.

w.c.

Maximum Inlet

14.0 inches

14.0 inches

Gas Pressure

w.c.

w.c.

Manifold

3.5 inches

10.0 inches

Pressure

w.c.

w.c.

A one-eighth (1/8) inch (3 mm) N.P.T. plugged tapping is
provided on the inlet and outlet side of the gas control for
a test gauge connection to measure the manifold pressure.

The fireplace and its individual shut-off valve must be
disconnected from the gas supply piping system during
any pressure testing of the system at test pressures in
excess of one-half (1/2) psig (3.5 kPa).

The fireplace must be isolated from the gas supply piping
system by closing its individual shut-off valve during any
pressure testing of the gas supply piping system at test
pressures equal to or less than one-half (1/2) psig (3.5 kPa).

u

Figure 24.   Gas Supply Line

USE A WRENCH ON
SHUT-OFF VALVE
WHEN TIGHTENING
GAS LINE.

MANUAL

SHUT-OFF

VALVE

FLEX CONNECTOR

GAS VALVE

GAS LINE

ACCESS

CONTROL VALVE

Содержание Pier-PV-IPI

Страница 1: ...E REFERENCE 1 This appliance may be installed in an af termarket permanently located manu factured mobile home where not pro hibited by local codes 2 This appliance is only for use with the type of ga...

Страница 2: ...ERSTAND all instructions carefully before starting the installation FAILURE TO FOLLOW these installation instructions may result in a possible fire hazard and will void the warranty Prior to the first...

Страница 3: ...19 Step 4 Positioning Leveling and Securing the Fireplace 22 Step 5 The Gas Control System 22 Step 6 The Gas Supply Line 23 Step 7 Gas Pressure Requirements 23 Step 8 Wiring the Fireplace 24 Step 9 F...

Страница 4: ...riate to the particular installation Refer to the National Fuel Gas Code ANSI Z223 1 NFPA54 current edition The Uniform Mechanical Code current edition and local Building Officials for the options all...

Страница 5: ...ructions will void the own er s warranty and may present a fire hazard The Heat N Glo Warranty will be voided by and Heat N Glo disclaims any responsibility for the following actions Installation of a...

Страница 6: ...DOOR TOP STANDOFFS 1 2 13mm 2 43 5 8 1107mm 42 5 8 1081mm 42 1067mm 32 3 4 829mm 21 533mm 32 5 16 820mm 8 1 2 216mm 37 7 16 950mm 17 15 16 455mm 24 610mm 21 533mm 12 304mm 2 ELECTRICAL ACCESS 4 100mm...

Страница 7: ...mm 8 1 2 216mm 24 610mm 2 9 16 64mm 4 1 2 114mm 47 5 8 1208mm 32 3 4 829mm 12 304mm 2 4 100mm 2 ELECTRICAL ACCESS GAS LINE ACCESS 26 5 8 676mm 10 1 2 266mm 4 1 16 102mm 2 4 1 2 114mm 2 4 3 4 121mm 2 5...

Страница 8: ...or after the fireplace is set in place Framing should be positioned to accommo date wall coverings and fireplace facing material The dia gram below shows framing reference dimensions CAUTION MEASURE F...

Страница 9: ...er or heavier Model A B C D PIER PV IPI 42 1 8 42 1 2 23 25 5 8 ST PV IPI 47 5 8 42 1 2 23 26 5 8 Figure 4 Framing Dimensions NOTE DIMENSIONS SHOWN IN INCHES Showscenterof 12 x 12 vent framing holes f...

Страница 10: ...r horizontal vent runs NO OTHER VENTING SYS TEMS OR COMPONENTS MAY BE USED Detailed installation instructions are included with each vent termination kit and should be used in conjunction with this In...

Страница 11: ...IGHT OUT HORIZONTAL VENTING H FT 36 MIN 914 mm 40 MAX 12 2 M 8 900 Bends MAX Figure 7 STRAIGHT UP VERTICAL VENTING V FT 40 MAX 12 2 M 8 900 Bends MAX Figure 8 V H VERTICAL DROP V MAX Run 48 1219 mm 8...

Страница 12: ...as fireplaces to draft properly If the home experiences negative pressure or is likely to experience negative pressure connection to an outside air source is mandatory A 4 inch side collar see Figure...

Страница 13: ...ing 9 9 INTERIOR WALL SHIELD FLEX PIPE For Vertical Runs One ceiling firestop is REQUIRED at the hole in each ceiling through which the vent passes To install firestops for vertical runs that pass thr...

Страница 14: ...4 REQUIRED NOTE There must be NO INSULATION or other combustibles inside the framed firestop opening WARNING VENTING TERMINALS SHALL NOT BE RECESSED INTO A WALL OR SIDING VENT TERMINATION CLEARANCES...

Страница 15: ...ensions specified for vinyl or non vinyl siding and soffits 1 There must be 3 feet minimum between termination caps 2 All mechanical air intakes within 10 feet of a termination cap must be a minimum o...

Страница 16: ...AGRAM FOR MINIMUM HEIGHTS PROVIDED THE TERMINA TION CAP IS AT LEAST 20 INCHES FROM A VER TICAL WALL AND 2 FEET BELOW A HORIZONTAL OVERHANG NOTE This also pertains to vertical vent systems in stalled o...

Страница 17: ...t to the floor The diagram below shows how to properly position level and secure the fireplace Figure 22 Proper Positioning Leveling and Securing of a Fireplace Step 5 The Gas Control System WARNING T...

Страница 18: ...t does not penetrate the actual firebox Open the fireplace lower grille insert the gas supply line through the gas line hole and connect it to the shut off valve When attaching the pipe support the co...

Страница 19: ...WHT ORG GRN WHT ON OFF WALLSWITCH BRN BRN BLK WHT BLK WHT BLK WHT BLK TERMINAL BLOCK BULB SOCKET ASSEMBLY 3 ROCKER SWITCH BLK OPTIONAL ELECTRIC EMBER KIT EMBERKIT MS RED BRN BLK BL K WHT RED BRN BLK W...

Страница 20: ...Figures 27 Figure 26 Fan Wiring Diagram Optional Accessories Optional fan and remote control kits require that 110 120 VAC be wired to the factory installed junction box before the fireplace is perman...

Страница 21: ...stible material such as wood can be placed on the top edge and sides of the fireplace Hearth Extensions A hearth extension may be desirable for aesthetic reasons However ANSI or CAN CGA testing standa...

Страница 22: ...el Type PIER PV IPI TEMPERED ST PV IPI TEMPERED Heat N Glo fireplaces manufactured with tempered glass may be installed in hazardous locations such as bathtub enclosures as defined by the CPSC The tem...

Страница 23: ...rts at the rear of the burner Save the remaining ember materials for use during fire place servicing The bag of embers provided is suffi cient for 3 to 5 applications Replace the glass door and a fron...

Страница 24: ...ghting the fireplace double check the unit for possible obstructions that could be blocking the vent terminations or the front grilles Double check for faulty components Any component that is found to...

Страница 25: ...eriodically By Qualified service technician Task Make a visual check of the straight flame sensor rod Use emery cloth to carefully remove any existing film or white deposits Checking Flame Patterns Fl...