Heat-N-Glo LifeStyle Collection • Dakota 42, Dakota 42H • 4036-905 Rev. F • 11/04
7
C. Mantel Projections
B. Clearances
Figure 3.3 Clearances to Mantels or other Combustibles
above Appliance
Fire Risk.
•
Locate and install appliance to all
clearance specifications in manual
WARNING
Fire Risk.
Odor Risk.
•
Install appliance on hard metal or wood
surfaces extending full width and depth of
appliance.
•
Do NOT install appliance directly on
carpeting, vinyl, tile or any combustible
material other than wood.
WARNING
Figure 3.2
Framing Dimensions
A
B
C
D
Inches
24-1/8 43-7/8
49
43-7/8
mm
613
1114
1245
1114
84 INCHES
MINIMUM
*This appliance can be installed a minimum of 6 inches
from a combustible structure unless the structure is
vinyl which requires a minimum clearance of 48 inches.
Free standing installation
A
B
C
D
HEADER HEIGHT.
USE ONLY NONCOMBUSTIBLE
MATERIAL BELOW THE TOP OF
THE TOP STANDOFFS.