Heat-N-Glo LifeStyle Collection • Dakota 42, Dakota 42H • 4036-905 Rev. F • 11/04
11
Figure 6.1
Figure 6.2
Figure 6.3
Figure 6.4
Figure 6.5
D. Valve Access
Remove the inside valve access panel by lifting it up and
out.
Use a manometer on the lower out pressure tap. Start up
the fireplace to verify the pressure and adjust as necessary.
Reverse these steps to reassemble before log positioning.
Lift doors out and set aside. Remove the refractory side
panel and set aside.
RETAINING
STRIP
The gas valve can be accessed behind the cement refrac-
tory panel on the right side of the fireplace. Use a phillips
screwdriver to remove the two screws securing the refrac-
tory retaining strip.
Using a phillips screwdriver remove the exterior valve access
panel.