FIGURE 6. Straight Out Horizontal Flueing
H
H
MIN. RUN
MAX. RUN
13.1" (331mm)
24" (610mm)
H
FIGURE 7.
Flueing with One 90° Elbow
V
H
1´ MIN. (305 mm)
2´ MAX. (610 mm)
2´ MIN. (610 mm)
4´ MAX. (1.22 M)
3´ MIN. (914 mm)
6´ MAX. (1.86 M)
4´ MIN. (1.22 M)
8´ MAX. (2.48 M)
24´ MAX. (7.3 M)
8´ MAX. (2.48 M)
V
H
V (FT.)
H (FT.)
1' MIN. (305mm)
4' MAX. (1.22m)
2' MIN. (610mm)
8' MAX. (2.4m)
3' MIN. (914mm)
12' MAX. (3.7m)
4' MIN. (1.22m)
16' MAX. (4.9m)
V+H= 24’ MAX. (7.3m) H = 8' MAX. (2.4m)
FIGURE 8.
Flueing with One 90° Elbow
NOTE:
If a 90
o
elbow is first attached to the unit,
the maximum horizontal run is 3-feet (914mm).
NOTE:
For corner installations: A 6-inch (152mm)
section of straight pipe may need to be attached to
the fireplace before a 90
o
elbow, to allow the vent
pipe to clear the top standoffs.
H
V