
17
FIGURE 23.
NOTE: IF ANY OF THE ORIGINAL
WIRE AS SUPPLIED WITH THE
APPLIANCE MUST BE REPLACED,
IT MUST BE REPLACED WITH TYPE
105
•
C RATED WIRE.
FIGURE 24.
WARNING: DO NOT CONNECT 220 VAC TO THE
GAS CONTROL VALVE OR CONTROL WIRING SYS-
TEM OF THIS MODEL.
NEUTRAL (BLUE)
BLUE
HOT (BROWN)
BROWN
BLACK
BLACK
JUNCTION BOX
FAN
BLUE
BROWN
YELLOW/GREEN
BLUE
BRN
YW/GR
BLK
BLK
TEMP. SENSOR
SWITCH
BLK
BLK
SPEED CONTROL
FAN WIRING DIAGRAM
BLK
BLK
YELLOW/GRN
YELLOW/GRN
BLUE
BRN
BRN
BL
U
E
GRD
BL
UE
JUNCTION BOX DETAIL
FAN
TEMPERATURE
SENSOR SWITCH
FAN SPEED
CONTROL
JUNCTION BOX
1.5 FAN
These heaters have a factory installed Fan, Electrical
Junction Boxes, variable speed Rheostat Control Switch
and Temperature Sensor Switch for the fan. These com-
ponents are located behind the lower grille.
Use of the fan requires that the Junction Box (factory
installed) be connected to 240 VAC service before per-
manently enclosing the heater. The factory installed
power cord is attached on the lower front right exterior
side of the heater. Figure 23 shows the fan, switches,
and fan wiring diagram. See Figure 24 for wire connec-
tion detail.