Heat-N-Glo 6000TRS-AU Скачать руководство пользователя страница 31

33

LIMITED 10 YEAR WARRANTY

HEAT-N-GLO, a division of Hearth Technologies Inc.

In order to presumptively establish the dates to which your HEAT-N-GLO Limited 10 Year Warranty runs, you must
mail the completed warranty card to HEAT-N-GLO, a division of Hearth Technologies Inc., 20802 Kensington
Boulevard, Lakeville, MN 55044, within 60 days of the date of fireplace installation.  If you fail to do so, you may
be required to prove the date of installation before warranty work can be performed.

The warranty exclusions and limitations of liability are effective upon installation of the fireplace.

Subject to the conditions set forth herein, HEAT-N-GLO, a division of Hearth Technologies Inc. ("HEAT-N-GLO")
extends the following warranty with respect to HEAT-N-GLO, a division of Hearth Technologies Inc..

If HEAT-N-GLO  is reasonably satisfied that any part or portion of the fireplace covered by this Limited Warranty
is defective in material or workmanship under normal use and service as described in the Operating Instructions,
HEAT-N-GLO will take the following actions:

1. If the defect is reported during the first year from the date of installation (stainless steel burners and fiber logs

are covered for 3 years), HEAT-N-GLO will replace or repair the defective components at its sole expense.  The
decision whether to replace a component shall be made at HEAT-N-GLO's sole discretion.  This Limited
Warranty does not cover components broken during shipping, misuse or careless handling.   HEAT-N-GLO shall
be not responsible for any indirect, incidental, or consequential damages or for any costs other than those
incurred by HEAT-N-GLO to repair or replace the defective component.  If components (including venting) other
than factory approved components are used, all warranty and liability on the fireplace is voided.

Defects

reported after the first year will not be covered by warranty unless they fall within the purview of
paragraph 2 or 3 below.

2. If the following defects are reported during the second year after the date of installation, HEAT-N-GLO will supply

replacement parts at the current wholesale price: defective electrical or manual components, optional
components or accessories, and glass panels (not including glass panels broken during misuse or careless
handling).  HEAT-N-GLO shall not be responsible for any labor, transportation or other costs.  Furthermore, it
shall not be liable for any indirect, incidental or consequential damages.

3. HEAT-N-GLO will replace or repair a defective firebox or heat exchanger, at any time during the 10 years from

the date of installation. The decision whether to replace the defective component shall be made at HEAT-N-
GLO's sole discretion. HEAT-N-GLO shall not be responsible for any indirect, incidental or consequential
damages or for any costs other than those incurred by HEAT-N-GLO to repair or replace the defective
component.

This Limited Warranty is the exclusive remedy available to you.  If HEAT-N-GLO cannot effectively resolve a
warranty problem in an expedient and cost-effective manner, it can discharge its entire warranty liability by refunding
the price of the product to you.

Products made by other manufacturers, whether sold with the fireplace or added thereafter, are NOT covered by
this Limited Warranty.  The use of other unauthorized components will make this warranty null and void.  This Limited
Warranty will also be void if the appliance is not installed by a qualified installer in accordance with the Installation
Instructions.  Furthermore, the Limited Warranty will be  void if the fireplace is not operated, at all times, according
to the Operating Instructions furnished with the fireplace. Any service work must be performed by authorized service
representatives.

EXCEPT TO THE EXTENT PROVIDED BY LAW, NO OTHER EXPRESS OR IMPLIED WARRANTIES,
INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, SHALL
APPLY TO THE FIREPLACE PRODUCT.  In States that do not allow limitations on how long an implied warranty
lasts, or do not allow exclusion of indirect damages, those limitations or exclusions may not apply to you.  You may
also have additional rights not covered in this Limited Warranty.

HEAT-N-GLO reserves the right to make changes at any time, without notice, in design, material, specifications
and prices.  It also reserves the right to discontinue styles and products.

Содержание 6000TRS-AU

Страница 1: ...4 USA 1 888 427 3973 392 900D 10 02 INSTALLATION AND OPERATION INSTRUCTIONS This product is covered by one or more of the following patents United States 4 112 913 4 408 594 4 422 426 4 424 792 4 520...

Страница 2: ...nual Report to your dealer any parts dam aged in shipment specifically check glass condition The gas logs and flue system components are in sepa rate packages Read all instructions before starting ins...

Страница 3: ...Installer Testing 21 2 0 OPERATING INSTRUCTIONS 21 2 1 Safety and Lighting Information 23 2 2 Safety Information 23 2 3 Lighting Instructions 24 2 4 Fan Operation 25 3 0 SERVICING AND MAINTENANCE 25 3...

Страница 4: ...r remote control are desired If the heater is to be installed on carpeting or tile or on any combustible material other than wood flooring the heater should be installed on a metal or wood panel that...

Страница 5: ...FIGURE 2 Heater Dimensions Locations and Space Requirements 1 1 Locating the Heater The diagram See figure 2 shows space and clearance requirements for locating a heater within a room Minimum Clearan...

Страница 6: ...2 1066mm 978mm 559mm 6837mm 1054mm FIGURE3 Framing Dimensions For minimum clearances see the direct vent termination clearance diagrams on page 7 1 2 Framing the Heater Framing can be built before or...

Страница 7: ...ut 300 Appliances over 50 MJ h input 500 b From the ground or above a balcony 300 c From a return wall or external corner 500 d From a gas meter M 1000 e From an electricity meter or fuse box P 500 f...

Страница 8: ...UE SYSTEM Figure 5 shows straight up vertical flue system approved for use on this model STRAIGHT OUT HORIZONTAL FLUE SYSTEM Figure 6 shows straight out horizontal flue systems ap proved for use on th...

Страница 9: ...M V H V FT H FT 1 MIN 305mm 4 MAX 1 22m 2 MIN 610mm 8 MAX 2 4m 3 MIN 914mm 12 MAX 3 7m 4 MIN 1 22m 16 MAX 4 9m V H 24 MAX 7 3m H 8 MAX 2 4m FIGURE8 Flueing with One 90 Elbow NOTE If a 90o elbow is fi...

Страница 10: ...2 48m 3 MIN 914mm 4 MAX 1 22m 12 MAX 3 72m 4 MIN 1 22m 6 MAX 1 8m 16 MAX 4 9m 20 MAX 6 1m 6 MAX 1 8m 16 MAX 4 9m H1 V H FIGURE 10 Flueing with Two 90 Elbows V FT H H1 FT 1 MIN 305mm 4 MAX 1 22m 2 MIN...

Страница 11: ...86 m 12 MAX 3 6 m 4 MIN 1 22 m 8 MAX 2 48 m 16 MAX 4 9 m 8 MAX 2 48 m 16 MAX 4 9 m NOTE V V MAX 36 10 9 m FLUEING WITH THREE 3 90 ELBOWS FIGURE11 Flueing with three 90 elbows V H H H1 H2 1 MIN 305 mm...

Страница 12: ...3 MIN 914mm 12 MAX 3 7m 4 MIN 1 22m 16 MAX 4 9m NOTE H H1 16 MAX 4 9m V V1 H H1 36 MAX 10 9m V FT H H1 FT 1 MIN 305mm 4 MAX 1 22m 2 MIN 610mm 8 MAX 2 4m 3 MIN 914mm 12 MAX 3 7m 4 MIN 1 22m 16 MAX 4 9m...

Страница 13: ...TOVECEMENTMUSTBEPLACED AROUNDTHEINNERPIPEHEATERSTARTING COLLARBEFOREATTACHINGTHEFIRSTFLUE COMPONENT FAILURE TO SEAL THIS JOINT MAY CAUSE THE HEATER TO OPERATE IM PROPERLY SEEFIGURE14 WARNING ENSURETHA...

Страница 14: ...er of the hole is one 1 inch 25mm above the center of the horizontal flue pipe Position the firestops on both sides of the hole pre viously cut and secure the firestops with nails or screws The heat s...

Страница 15: ...hole FIGURE 20 Attic Firestop C Flue Termination For Horizontal Terminations To attach and secure the termination to the last section of horizontal flue Rotate and interlock the ends as described at t...

Страница 16: ...accordingly Cover the opening of the installed flue pipes Cut and frame the roof hole Use framing lumber the same size as the roof rafters and install the frame securely Flashing anchored to the frame...

Страница 17: ...BRN BRN BLUE GRD BLUE JUNCTION BOX DETAIL FAN TEMPERATURE SENSOR SWITCH FAN SPEED CONTROL JUNCTION BOX 1 5 FAN These heaters have a factory installed Fan Electrical Junction Boxes variable speed Rheo...

Страница 18: ...EALED A 150 C MINIMUM SEALANT MATERIAL MUST BE USED THESE JOINTS ARE NOT REQUIRED TO BE SEALED ONLY NON COMBUSTIBLE MATERIAL USING 150 C MINIMUM ADHESIVE IF NEEDED CAN BE APPLIED AS FACING TO THE FIRE...

Страница 19: ...V382 701 Locate log 1 on grate with knotches and push log towards rear of firebox LOG 2 SRV382 702 Locate log 2 on grate with knotches Slide left end of log forward and right side back against tab Log...

Страница 20: ...t the right end on top of log 2 LOG 5 SRV382 705 Place bottom of log 5 between the 4th and 5th grate bars rest the top onto log 1 LOG 6 SRV438 724 Place the Y shaped part of log 6 over the 3rd grate b...

Страница 21: ...building WARNING THIS UNIT IS NOT FOR USE WITH SOLID FUEL The control system for this model is a millivolt type It consists of a gas control valve variable regulator a stand ing pilot assembly a ther...

Страница 22: ...FORE THE UNIT CAN BE PLACED INTO SAFE OP ERATION DO NOT USE THIS APPLIANCE IF ANY PART HAS BEEN UNDER WATER IMMEDIATELY CALL AQUALIFIEDSERVICETECHNICIANTOINSPECT THE UNIT AND TO REPLACEANY PART OF TH...

Страница 23: ...has been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the gas control system which has been under water 2 1 SAFETY LIGHTING INFORMATI...

Страница 24: ...houldnotrequireaccessingforlighting purposes The pilot is located inside the combustionchamber THERMOPILE PILOTBURNER 6 To put the control in the pilot position turn the control knob counter clockwise...

Страница 25: ...and burner area surrounding the logs clean by vacuuming or brush ing at least twice a year CAUTION THE LOGS GET VERY HOT HANDLE ONLY WHEN COOL WARNING DO NOT USEABRASIVE CLEANERS ON THE GLASS DOOR AS...

Страница 26: ...m the underside of the thermopile The thermopile can then be sepa rated from the pilot bracket Unscrew the pilot assembly bracket and remove NOTE When removing the pilot assembly carefully pull the el...

Страница 27: ...gnitor 1 Using a match light pilot If pi lot lights turn off pilot and trig ger the red or black button again If pilot lights an improper gas air mixture caused the bad light ing and a longer purge pe...

Страница 28: ...he micro switch and connect to terminal TP on the gas valve Turn green knob to pilot position depress and light pilot light If meter reading is greater than 325 m v after 30 seconds the pilot generato...

Страница 29: ...llow for igni tion or the heater continues to shut off disconnect the limit switch wire from the gas valve and repeat the lighting instruc tions If the pilot and burner re main lit after the heater wa...

Страница 30: ...debris or blockage 1 Adjust the log set so that the flame does not impinge on it 1 Adjust the air shutter at the base of the burner 1 Inspect the opening at the base of the burner It is imperative th...

Страница 31: ...nt wholesale price defective electrical or manual components optional components or accessories and glass panels not including glass panels broken during misuse or careless handling HEAT N GLO shall n...

Отзывы: