![Heat Link ELBP TS Series Скачать руководство пользователя страница 6](http://html1.mh-extra.com/html/heat-link/elbp-ts-series/elbp-ts-series_installation-operation-and-maintenance-manual_2115892006.webp)
5
ELBPxxTSxx
Installation, Operation, and Maintenance Manual
L6ELBPxxTSx 2022 DRAFT
®
Link
Heat
#
Components
Component Description
Part Number (Qty.)
ELBP18TSxx
ELBP30TSxx
ELBP50TSxx
1
Electric boiler
The electric boiler supplies hot water
to the system, and is activated when
there is a call for heat via a built in flow
switch (see page xx for details).
Requires 240V power source.
HA008240 (1)
HA011240 (1)
HA018240 (1)
2
Junction box
Wiring connection box for 240V
n/a
n/a
n/a
3
StatLink® 8 Zone Wired
Module
Connects room thermostats to their
corresponding actuators. Each zone has
an LED which indicates a call for heat.
40318 (1)
4
24Vac Transformer
Supplies 24V power to the StatLink®
(1)
(1)
(1)
5
Electrical box
Houses transformer wiring
(1)
(1)
(1)
6
Terminal strip
Field wiring connections
(1)
(1)
(1)
7
Pressure relief valve
Vents excess system pressure
(1)
(1)
(1)
8
Y strainer
Removes entrained air
(1)
(1)
(1)
9
Automatic air vent
Automatically vents entrained air
(1)
(1)
(1)
10
Pump
The circulator moves the heated
fluid through the hydronic system
when there is a call for heat from the
thermostat. See pg 6 for pump curve.
PUMP1558 (1)
11
Ball valve
Allows for panel isolation for fill &
purge/maintenance
(1)
(1)
(3)
12
Return manifold
Modular TwistSeal® manifold for
distribution to heating zones
13
Supply manifold
Modular TwistSeal® manifold for
distribution to heating zones
14
Accessory pack
Installation Acessories
ACCELBP (1)
a
1" nitrile washer
Spare washers for pump
NTRWSH1 (4)
b
¾" nitrile washer
Washers for adapters, plus 2 spares for
ball valves
NTRWSH34 (8)
c
Mounting screw
Screws to mount panel to wall
(9)
d
Piping adapters
¾"MSBP χ 1"NPT Lead Free adapters
(2)
Enclosure Dimensions
Stk. #
Height
Width
Depth
ELBP18
371/2”
291/4”
43/4”
ELBP30
ELBP50
Panel Dimensions