background image

Retro-DWS Installation

3 of 12

•  Push the pre-drilled dissolving ballpoint onto the 

end-seal of the tubular heater making sure it is 

firmly in place. Then begin to feed the tubular heat-

ing cable system into the pipe through the installed 

flexible coupler. 

Note:

 The pre-drilled dissolving ballpoint is designed 

to reduce the friction of the Retro-DWS tubular 

heater end-seal during installation. It also aids the 

passing of the tubular heater product through and 

around fittings located along length the pipe. 

Pre-drilled 

disolving

ball point

5

1

•  Loosen the clamps on 

either end of the 4" 

flexible pipe coupler, 

do not remove the 

clamps from their 

seated location on the 

flexible pipe coupler 

body.

•  Remove threaded cleanout plug.

CAUTION

: Effluent may be present  

when threaded cap is removed.

2

•  Slide the flexible pipe coupler onto the now exposed spigot 

end of the male threaded adapter fitting and tighten the clamp 

to 60 inch-lb.

•  Apply Teflon tape or thread sealant to the 4" ABS threaded 

male adapter SPIG X MIPT.

•  Make sure to apply 

the Teflon tape in 

the direction of the 

threads to ensure it 

remains tight during 

threading of the 

fittings. 

•  Thread the male 

adapter into the 

clean-out female entry 

point. 

Standard 4-inch Cleanout

3

4

Содержание Retro-DWS Series

Страница 1: ...Check on GFC Models 7 Limited Warranty 7 Extended Warranty Application Form 9 Important Safety Instructions and Rules for safe Installation and Operation FIRE AND SHOCK HAZARD This component is an ele...

Страница 2: ...wrench automatic release at 60 IN LB WARRANTY Extended 10 year limited product warranty Ordering Chart Example DWS 5 100 GFC Cord Set Type GFC Ground fault protected CS Cord connected no GFCI Length o...

Страница 3: ...illed disolving ball point 5 1 Loosen the clamps on either end of the 4 flexible pipe coupler do not remove the clamps from their seated location on the flexible pipe coupler body Remove threaded clea...

Страница 4: ...ON Effluent may be present when threaded cap is removed 4 2 Apply Teflon tape or thread sealant to the 3 ABS threaded male adapter SPIG X MIPT Make sure to apply the Teflon tape in the direction of th...

Страница 5: ...etro DWS tubular heater end seal during installation It also aids the passing of the tubular heater product through and around fittings located along length the pipe 7 Tighten clamp around Retro DWS t...

Страница 6: ...cycle the system in an on off operation saving power consumption and maintain a certain pipe temperature A sensor lead must be placed on the coldest section of pipe Timers are used to duty cycle the...

Страница 7: ...RIOD 120 months from date of purchase or 123 months from date of manufacture which ever occurs first ACCESSORIES COMPONENTS ELECTRONICS Not manufactured by Heat Line are warranted only to the extent o...

Страница 8: ...Retro DWS Installation 8 of 12 Page left empty intentionally...

Страница 9: ...Retro DWS Installation 9 of 12 Page left empty intentionally...

Страница 10: ...ess of the information and disclaims any liability regarding its use Heat Line s only obligations are those in the Heat Line Standard Terms and Conditions of Sale for this product and in no case will...

Страница 11: ...full amount Name on Card Card Number __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ Expiration Date __ __ __ __ CONGRATULATIONS You have just purchased the most advanced internal freeze protection s...

Страница 12: ...will be based upon the date of manufacture plus 90 days PROOF OF PURCHASE If a proof of purchase copy is submitted with this warranty application form the warranty period will be effective as of invoi...

Отзывы: