Retro-DWS Installation
5 of 12
Pre-drilled
disolving
ball point
6
5
• Insert the Retro-DWS pipe core
into drain until the bushing
interfaces into the coupling.
• Push the pre-drilled dissolving ballpoint onto the end-
seal of the tubular heater making sure it is firmly in
place. Then begin to feed the tubular heating cable sys-
tem into the pipe through the installed flexible coupler.
Note:
The pre-drilled dissolving ballpoint is designed
to reduce the friction of the Retro-DWS tubular heater
end-seal during installation. It also aids the passing of
the tubular heater product through and around fittings
located along length the pipe.
7
• Tighten clamp around Retro-DWS to 60 inch-lb.
• In accordance with standard industry practices test the integ-
rity of the seal.
• Plug in heater and Test/Reset GFCI located in cord set.
Coldest
section
of pipe
Thermostat
sensor
Insulation
8
9
After all plumbing fittings have been completely installed.
It is time to energize your Retro-DWS system. Carefully follow
the Electrical System Check Instructions below.
Refer to Control Devices and Insulation
Installation on page 7 to complete your
installation.