13
Heat & Glo • SUPREME-I25-IFT, SUPREME-I30-IFT, SUPRM-I30LP-IFT, SUPREME-I35-IFT Owner’s Manual • 2532-981 Rev. J • 7/20
Figure 3.7
Control Cavity
NOTICE:
Some functionality will be lost when using battery
backup including fan, lights, or any other auxiliary functions
that require household 110-120 VAC power.
I. Operation During A Power Outage -
IntelliFire Touch
®
SEE SECTION 4 FOR COMPONENT ACCESS DETAILS.
3. Locate the battery pack and insert four AA cell
batteries. The battery pack is shipped in the appliance
manual bag. Battery polarity must be correct or module
damage will occur. Connect to black and red wires
labelled “BATT”. A complete wiring diagram is included
in the Electrical section of the appliance Installation
Manual.
4. When operating the appliance under battery power,
the battery pack
MUST
be located outside of the
appliance.
5. Before operating appliance install decorative front.
If removed, install glass seal plate and fixed glass
assembly.
WARNING!
Glass seal plate must be properly installed.
Risk of elevated component temps and carbon monox
-
ide exposure.
6. Turn the appliance on according to the instructions
below for the appropriate type of control:
Wireless Remote:
• Remote receiver is attached to the ignition
module
• Toggle surround manual reset switch position
to “ON”. See Figure 3.9.
Check to make sure
ignition module switch is in the “REMOTE”
position.
• Use the remote to turn the appliance on.
• To preserve battery life, do not use the HI/LO
flame or THERMOSTAT options.
Ignition Module:
• Toggle surround manual reset switch position to
“ON”.
See Figure 3.9.
• Locate the ignition module in the control cavity.
• Slide the ON/REMOTE/OFF switch to the ON
position.
See Figure 3.9.
NOTICE:
Batteries should only be used as a power source
in the event of an emergency power outage. Batteries
should not be used as a primary long-term power source.
Batteries tend to corrode over time.
To Return to Operation Using Electrical (AC) Power
• Toggle surround manual reset switch position to
“OFF”. See Figure 3.9.
• Remove decorative front.
• Disconnect the battery pack, remove the batteries
and store the battery pack for future use.
• Slide the ON/REMOTE/OFF switch to the REMOTE
position.
• Replace decorative front. If removed, replace glass
seal plate and fixed glass assembly.
WARNING!
Glass seal plate must be properly installed.
Risk of elevated component temps and carbon monox
-
ide exposure.
• Resume normal operation with the RC400.
To Operate Fireplace Using Battery Power (DC):
1. Access the control cavity of the appliance. See Figure
3.7 for location. The decorative front will need to be
removed.
The IntelliFire Touch intermittent pilot ignition system
comes with a battery backup system that enables the
flame to operate in a power outage. See appliance
manual bag for battery pack. Batteries should not be
placed in the battery pack while using electrical power
to operate the fireplace. Remove batteries from battery
pack when power has been restored and remove battery
pack from the appliance.
NOTE:
Battery pack may have been previously installed
during installation of appliance as shown in Figure 3.8.
2. Toggle surround manual reset switch position to
“OFF”. See Figure 3.9. Check to make sure the
ignition module switch is
NOT
in the “ON” position.
Figure 3.8
Battery Pack Installed
BATTERY PACK