J.  Detailed Component Operating 

Instructions - IntelliFire Touch

IFT-ECM Detailed Operating Instruction

Figure 3.9  IFT-ECM

3 POSITION SWITCH

TOP VIEW

LED INDICATOR

DANGER

Risk of Explosion 

DO NOT

 cycle the ON/OFF/REM selector 

switch more than one time within a five minute 

period.  Gas may accumulate in firebox.  Call 

a qualified service technician.

DANGER

Risk of Explosion 

DO NOT

 cycle the ON/OFF/REM selector 

switch more than one time within a five minute 

period.  Gas may accumulate in firebox.  Call 

a qualified service technician.

4.  An IFT-ECM reset is required if the module is in a 

lock-out condition.  When this occurs, the appliance 

is shut down and the IFT-ECM status indicator LED 

will be blinking a RED/GREEN error code along with a 

one-time audible double- beep.  If the IFT-ECM is in a 

lock-out condition, refer to the troubleshooting chart to 

interpret the error code and take corrective action as 

required.  To reset the IFT-ECM after a lock-out error

1.  The Electronic Control Module (IFT-ECM) has a 

three-position ON/OFF/REMOTE selector switch 

that must be set for proper operation. See Figure 

3.8.  When changing switch positions,it is important 

to pause in each position for 1-2 seconds. 

 

OFF Position:   

 

The appliance will not respond to any commands 

from a wired wall switch, IFT-RC150  or IFT-RC400 

remote controls.  The unit should be in the OFF 

position during installation, service, backup battery 

installation, fuel conversion and to reset the IFT-

ECM in the event the system goes into a LOCK-

OUT mode as the result of a system error.  When 

switched to the OFF position while the appliance is 

operating, the system will shut down. 

 

ON  Position:   

 

The  appliance  will  ignite  and  run continuously at 

the HI flame setting.  No adjustment in flame height 

is possible.  

 

The IFT-ECM has a safety feature that will 

automatically shut down the fireplace after 

9 hours of continuous operation in the ON 

position.   

 

Remote Position:   

 

The remote position allows operation of the 

appliance from a wired wall switch, IFT-RC400 or 

IFT-RC150 remote controls.  The IFT-ECM switch 

must be in this position to pair the IFT-ECM with the 

IFT-ACM (if installed), and/or IFT-RC400 and IFT-

RC150 remote controls.  See the IFT-RC400 or IFT-

RC150 installation manual for detailed instructions 

on pairing the IFT-ECM with the remote controls. 

After successfully pairing a IFT-RC400, all installed 

accessories can be controlled by the IFT-RC400 

(see IFT-RC400 user manual).  The  RC150 allows 

the user to turn ON/OFF the flame in the appliance 

and activate the Cold Climate mode if desired.  The 

IFT-ECM has a safety feature that will automatically 

shut down the fireplace after 9 hours of continuous 

operation without receiving a command from the 

IFT-RC400, IFT-RC150 or wired wall switch. 

2.  If multiple control options are installed, the IFT-ECM 

will respond to the last command from the wired wall 

switch, IFT-RC400 or IFT-RC150.  

3.  The Pilot button on the IFT-ECM activates the Cold 

Climate function of the fireplace.  This function 

lights the pilot flame ONLY to provide enough heat 

in  the  firebox  to  reduce  condensation  in  cool,  high 

humidity ambient conditions.  To activate the Cold 

Climate press and hold the Pilot button for one 

second  and  release.    The  IFT-ECM  will  flash  two 

green  LED  blinks,  beep  twice  and  light  and  rectify 

the pilot flame. To turn off Cold Climate, press  

and hold the Pilot button for one second and release.  

The  IFT-ECM  will  flash  one  green  LED  blink,  beep 

once and shut down the pilot flame.  If remote controls 

are paired with the IFT-ECM, this feature can also be 

activated with the IFT-RC400 and/or IFT-RC150.

This model is shipped from the factory equipped with the 

IFT-RC400 remote. 

SEE SECTION 4 FOR COMPONENT ACCESS DETAILS.

Содержание SUPREME-I25-IFT

Страница 1: ...ration OWNER Retain this manual for future reference Contact your dealer with questions regarding installation operation or service DO NOT store or use gasoline or other flam mable vapors and liquids...

Страница 2: ...n the left side of the appliance outer wrap Homeowner Reference Information Model Number Not Not for for use use with with solid solid fuel fuel Ne Ne doit doit pas pas entre entre utilise utilise ave...

Страница 3: ...ications 6 C BTU Specifications 6 3 Important Safety and Operating Information A Appliance Safety 7 B General Operating Parts 8 C Fuel Specifications 8 D Wall Surface TV Guidelines 8 E Before Lighting...

Страница 4: ...zed HHT dealer distributor whichever occurs earlier However the warranty shall commence no later than 24 months following the date of product shipment from HHT regardless of the installation or occupa...

Страница 5: ...3 shipping or improper handling 4 improper operation abuse misuse continued operation with damaged corroded or failed components accident or improperly incorrectly performed repairs 5 environmental c...

Страница 6: ...eat in residential heating calculations NOTICE This installation must conform with local codes In the absence of local codes you must comply with the National Fuel Gas Code ANSI Z223 1 latest edition...

Страница 7: ...e to the off position and remove batteries 3 3 Important Safety and Operating Information Clear Space WARNING DO NOT place combustible objects in front of the fireplace or block louvers High temperatu...

Страница 8: ...MANTEL FIXED GLASS ASSEMBLY SECTION 4 B HEARTH CLEAR SPACE SECTION 3 A ACCESS TO BATTERY BACKUP SECTION 3 I FAN KIT SECTION 3 H 3 J REMOTE CONTROL SECTION 6 C Figure 3 3 Good Faith Wall Surface Tempe...

Страница 9: ...be validated at the me of each installa on TVs should not be used in situa ons where the actual TV temperature exceeds the manufacturers maximum allowable opera ng temperatures iden fied in the TV s...

Страница 10: ...ther decorative materials Check the wiring Check the air shutter adjustment Ensure that there are no gas leaks Verify Glass Seal Plate is properly installed See Figure 3 6 WARNING Glass seal plate mus...

Страница 11: ...e Follow the gas sup plier s instructions C Use only your hand to push in or turn the gas control knob Never use tools If the knob will not push in or turn by hand DO NOT D DO NOT use this appliance i...

Страница 12: ...h an additional 12 hours Note Some IPI systems have a safety feature that automatically shuts down the fireplace after 9 hours of continuous operation without receiving a command from the remote contr...

Страница 13: ...ition to ON See Figure 3 9 Locate the ignition module in the control cavity Slide the ON REMOTE OFF switch to the ON position See Figure 3 9 NOTICE Batteries should only be used as a power source in t...

Страница 14: ...he HI flame setting No adjustment in flame height is possible The IFT ECM has a safety feature that will automatically shut down the fireplace after 9 hours of continuous operation in the ON position...

Страница 15: ...reset switch to the off position See Figure 3 10 for reset switch location or Set the IFT ECM 3 position selector switch to OFF position Wait five 5 minutes to allow possible accumulated gas to clear...

Страница 16: ...asket Seal and Glass Inspection Annually Qualified Service Technician Log Inspection Annually Firebox Inspection Annually Control Compartment firebox Top Annually Burner Ignition Operation Annually A...

Страница 17: ...oaded latches forward and allow them to retract away from the glass assembly Tilt the bottom of the glass assembly outward until the top latches disengage Clean glass with a non abrasive commercially...

Страница 18: ...ray Access GLASS SEAL PLATE BASE REFRACTORY GLASS CLIP ASSEMBLIES GLASS CLIP ASSEMBY SCREW ACCESS Note Bottom right glass clip on 25 inch models must be removed to gain access to controls GLASS SEAL P...

Страница 19: ...ect venting and termination cap for blockage or obstruction such as plants bird nests leaves snow debris etc Verify termination cap clearance to subsequent construc tion building additions decks fence...

Страница 20: ...ition delay Inspect and ensure the lighting of the main burner occurs within four seconds of the main gas valve opening Inspect for lifting or other flame problems Verify air shutter setting is correc...

Страница 21: ...paint and logs Glass should be cleaned within 3 to 4 hours of initial burning to remove deposits left by oils from the manufacturing process A non abrasive cleaner such as gas fireplace glass cleaner...

Страница 22: ...the difference between the desired room temperature and actual temperature In thermostat mode the hearth appliance will start in HI flame but as the actual temperature approaches the desired set temp...

Страница 23: ...Verify IFT ECM slider switch is in ON or REM position Verify AC power available to junction box Verify AC DC adaptor is plugged into junction box and ECM Verify AC DC adaptor out put voltage is betwe...

Страница 24: ...connected to green main valve solenoid Check main valve solenoid resistance nominal is 60 ohms If open or shorted replace valve Verify valve inlet pressure is correct for gas type Pilot and main do n...

Страница 25: ...appliance Using non listed accessories could result in a safety hazard and will void the warranty Required Decorative Front Surround This appliance requires a Surround Decorative Front For available...

Страница 26: ...531 Y 1 Log 1 SRV2531 711 2 Log 2 SRV2531 712 3 Log 3 SRV2531 713 4 Log 4 SRV2531 714 5 Log 5 SRV2531 715 6 Slide Plate Assembly 2532 014 Tool Slide Plate Multi purpose 2532 140 Gasket 2532 113 7 Glas...

Страница 27: ...g 1 SRV2532 711 2 Log 2 SRV2532 712 3 Log 3 SRV2532 713 4 Log 4 SRV2532 714 5 Log 5 SRV2532 715 6 Slide Plate Assembly 2532 014 Tool Slide Plate Multi purpose 2532 140 Gasket 2532 113 7 Glass Clip Ass...

Страница 28: ...SRV2533 711 2 Log 2 SRV2533 712 3 Log 3 SRV2533 713 4 Log 4 SRV2533 714 5 Log 5 SRV2532 715 6 Log 6 SRV2538 715 7 Slide Plate Assembly 2532 014 Tool Slide Plate Multi purpose 2532 140 Gasket 2532 113...

Страница 29: ...I25 IFT 2531 131 SUPRM I30LP IFT 2532 131 SUPREME I30 I35 IFT 18 7 Gasket Bulkhead 438 407 18 8 Bulkhead w Flex Tube SRV7000 156 Y Orifice NG 40C SUPREME I25 IFT 582 840 Y Orifice Propane 53C 582 853...

Страница 30: ...m your dealer or distributor Stocked at Depot ITEM DESCRIPTION COMMENTS PART NUMBER Battery Pack SRV2326 134 Y Bolt Level Leg Qty 4 req 2073 162 24 Y Mineral Wool 050 721 RC400 Remote SRV2326 110 Y Sc...

Страница 31: ...__________________________________________________ ________________________________________________________________________________ DO NOT DISCARD THIS MANUAL NOTICE Leave this manual with party respo...

Отзывы: