HEAT GLO SUPREME-I25-IFT Скачать руководство пользователя страница 22

22

Heat & Glo  •  SUPREME-I25-IFT, SUPREME-I30-IFT, SUPRM-I30LP-IFT, SUPREME-I35-IFT Owner’s Manual  •  2532-981 Rev. J  •  7/20  

B.  Frequently Asked Questions - IntelliFire Touch Controls (IFT-RC400) 

Symptom

Possible Cause

Corrective Action

The appliance does not respond to 

commands from the remote control 

display does not light up when 

screen is touched.

Batteries are depleted.

Verify batteries are new. 

Batteries are incorrectly 

oriented.

Verify batteries are installed in correct orientation as shown on 

batteries receptacle. 

The display on remote lights up 

when screen is touched but it does 

not respond to commands.

Touchscreen has lost 

calibration.

Touchscreen needs to be re-calibrated.  Call dealer to have 

screen re-calibrated.

Child Lock is ON.

Check child lock icon located at the top of the remote display. If 

ON, it will show as a ‘locked’ symbol. To unlock, remove battery 

compartment door, locate child lock switch and move to ‘unlock’ 

position. Verify child lock icon on screen is now displayed in ‘un

-

lock’ position.

The remote displays the following 

message on-screen:  

No dealer info available.

Dealer information not 

programmed into remote.

Remote will still provide all available functions, and appliance is 

fully available for use.  Call dealer to have them program.

The remote displays the following 

message on-screen: 

Call  “Dealer Name & Number” to 

schedule maintenance.

300 hours of use.  Appliance is 

still fully functional.

The appliance has been burning for 300 hours and is due for a 

regular maintenance. Call dealer to have them perform mainte-

nance.

The room temperature displayed 

on the remote is either slow or 

quick to respond while operating in 

thermostat mode.

Remote is placed at a very 

short distance or too far away 

from the appliance.

Try to keep the remote close to the appliance but not directly in 

front of it.  The remote acts as the thermostat.

Remote is placed in the path of 

an air draft or vent.

Move the remote away from the direct path of air flow. The re

-

mote acts as the thermostat.

Flame Modulation

The control system is designed to automatically adjust the 

flame intensity based on the difference between the desired 

room temperature, and actual temperature.  In thermostat 

mode, the hearth appliance will start in HI flame, but as the 

actual temperature approaches the desired set temperature on 

the remote, the flame intensity will automatically decrease.  Au

-

tomatic flame modulation will result in more control of the tem

-

perature, and will cause the appliance to cycle OFF/ON less.

The appliance turns OFF the flame 

after extended periods of operation. 9 hour safety shutdown timer

This is normal behavior. The appliance has a safety timer that 

will automatically turn OFF the flame after nine hours of 

 

uninterrupted operation.

The remote displays the following 

message on-screen: Fan will turn 

on within 3 minutes.

Functioning as intended.

The appliance has a three minute delay timer before the fan is 

turned ON. This allows the air surrounding the appliance to be 

heated before being pushed into the room.

The remote displays the following 

message on-screen: 

“Replace remote batteries."

Low batteries in remote.

Install new batteries in the remote.

The remote is displaying an 

incorrect brand. 

Remote was programmed 

incorrectly.

Call dealer to have them program the remote with correct 

branding. Remote is still fully functional and the appliance is 

unaffected.  

After turning flame ON using 

remote, the flame does not turn 

ON immediately and instead a two 

minute timer is displayed.

Power vent is installed on the 

appliance.

This is expected behavior and the two minute timer is called a 

pre-purge timer. The flame will turn ON at the expiration of the 

timer.

The remote displays the following 

message on-screen: 

“Remote Control Communication 

Error.”

No power to appliance.

Verify home circuit breaker is on and master reset is on (if 

equipped).

Power outage.

Install new batteries in battery backup.

The remote displays the following 

message on -screen:  Sorry your 

appliance did not start.  Try again 

by pressing Flame On.

No power to appliance.  No gas 

to appliance.    Accumulation 

of air in gas line from extended 

period of appliance inactivity.  

Gas control system failure.

Verify that appliance has power and gas.  Verify that the appli-

ance accepts flame ON commands with an audible beep, and 

successfully  turns  flame  on  within  90  seconds.    If  this  failure 

persists, contact dealer for service.

Содержание SUPREME-I25-IFT

Страница 1: ...ration OWNER Retain this manual for future reference Contact your dealer with questions regarding installation operation or service DO NOT store or use gasoline or other flam mable vapors and liquids...

Страница 2: ...n the left side of the appliance outer wrap Homeowner Reference Information Model Number Not Not for for use use with with solid solid fuel fuel Ne Ne doit doit pas pas entre entre utilise utilise ave...

Страница 3: ...ications 6 C BTU Specifications 6 3 Important Safety and Operating Information A Appliance Safety 7 B General Operating Parts 8 C Fuel Specifications 8 D Wall Surface TV Guidelines 8 E Before Lighting...

Страница 4: ...zed HHT dealer distributor whichever occurs earlier However the warranty shall commence no later than 24 months following the date of product shipment from HHT regardless of the installation or occupa...

Страница 5: ...3 shipping or improper handling 4 improper operation abuse misuse continued operation with damaged corroded or failed components accident or improperly incorrectly performed repairs 5 environmental c...

Страница 6: ...eat in residential heating calculations NOTICE This installation must conform with local codes In the absence of local codes you must comply with the National Fuel Gas Code ANSI Z223 1 latest edition...

Страница 7: ...e to the off position and remove batteries 3 3 Important Safety and Operating Information Clear Space WARNING DO NOT place combustible objects in front of the fireplace or block louvers High temperatu...

Страница 8: ...MANTEL FIXED GLASS ASSEMBLY SECTION 4 B HEARTH CLEAR SPACE SECTION 3 A ACCESS TO BATTERY BACKUP SECTION 3 I FAN KIT SECTION 3 H 3 J REMOTE CONTROL SECTION 6 C Figure 3 3 Good Faith Wall Surface Tempe...

Страница 9: ...be validated at the me of each installa on TVs should not be used in situa ons where the actual TV temperature exceeds the manufacturers maximum allowable opera ng temperatures iden fied in the TV s...

Страница 10: ...ther decorative materials Check the wiring Check the air shutter adjustment Ensure that there are no gas leaks Verify Glass Seal Plate is properly installed See Figure 3 6 WARNING Glass seal plate mus...

Страница 11: ...e Follow the gas sup plier s instructions C Use only your hand to push in or turn the gas control knob Never use tools If the knob will not push in or turn by hand DO NOT D DO NOT use this appliance i...

Страница 12: ...h an additional 12 hours Note Some IPI systems have a safety feature that automatically shuts down the fireplace after 9 hours of continuous operation without receiving a command from the remote contr...

Страница 13: ...ition to ON See Figure 3 9 Locate the ignition module in the control cavity Slide the ON REMOTE OFF switch to the ON position See Figure 3 9 NOTICE Batteries should only be used as a power source in t...

Страница 14: ...he HI flame setting No adjustment in flame height is possible The IFT ECM has a safety feature that will automatically shut down the fireplace after 9 hours of continuous operation in the ON position...

Страница 15: ...reset switch to the off position See Figure 3 10 for reset switch location or Set the IFT ECM 3 position selector switch to OFF position Wait five 5 minutes to allow possible accumulated gas to clear...

Страница 16: ...asket Seal and Glass Inspection Annually Qualified Service Technician Log Inspection Annually Firebox Inspection Annually Control Compartment firebox Top Annually Burner Ignition Operation Annually A...

Страница 17: ...oaded latches forward and allow them to retract away from the glass assembly Tilt the bottom of the glass assembly outward until the top latches disengage Clean glass with a non abrasive commercially...

Страница 18: ...ray Access GLASS SEAL PLATE BASE REFRACTORY GLASS CLIP ASSEMBLIES GLASS CLIP ASSEMBY SCREW ACCESS Note Bottom right glass clip on 25 inch models must be removed to gain access to controls GLASS SEAL P...

Страница 19: ...ect venting and termination cap for blockage or obstruction such as plants bird nests leaves snow debris etc Verify termination cap clearance to subsequent construc tion building additions decks fence...

Страница 20: ...ition delay Inspect and ensure the lighting of the main burner occurs within four seconds of the main gas valve opening Inspect for lifting or other flame problems Verify air shutter setting is correc...

Страница 21: ...paint and logs Glass should be cleaned within 3 to 4 hours of initial burning to remove deposits left by oils from the manufacturing process A non abrasive cleaner such as gas fireplace glass cleaner...

Страница 22: ...the difference between the desired room temperature and actual temperature In thermostat mode the hearth appliance will start in HI flame but as the actual temperature approaches the desired set temp...

Страница 23: ...Verify IFT ECM slider switch is in ON or REM position Verify AC power available to junction box Verify AC DC adaptor is plugged into junction box and ECM Verify AC DC adaptor out put voltage is betwe...

Страница 24: ...connected to green main valve solenoid Check main valve solenoid resistance nominal is 60 ohms If open or shorted replace valve Verify valve inlet pressure is correct for gas type Pilot and main do n...

Страница 25: ...appliance Using non listed accessories could result in a safety hazard and will void the warranty Required Decorative Front Surround This appliance requires a Surround Decorative Front For available...

Страница 26: ...531 Y 1 Log 1 SRV2531 711 2 Log 2 SRV2531 712 3 Log 3 SRV2531 713 4 Log 4 SRV2531 714 5 Log 5 SRV2531 715 6 Slide Plate Assembly 2532 014 Tool Slide Plate Multi purpose 2532 140 Gasket 2532 113 7 Glas...

Страница 27: ...g 1 SRV2532 711 2 Log 2 SRV2532 712 3 Log 3 SRV2532 713 4 Log 4 SRV2532 714 5 Log 5 SRV2532 715 6 Slide Plate Assembly 2532 014 Tool Slide Plate Multi purpose 2532 140 Gasket 2532 113 7 Glass Clip Ass...

Страница 28: ...SRV2533 711 2 Log 2 SRV2533 712 3 Log 3 SRV2533 713 4 Log 4 SRV2533 714 5 Log 5 SRV2532 715 6 Log 6 SRV2538 715 7 Slide Plate Assembly 2532 014 Tool Slide Plate Multi purpose 2532 140 Gasket 2532 113...

Страница 29: ...I25 IFT 2531 131 SUPRM I30LP IFT 2532 131 SUPREME I30 I35 IFT 18 7 Gasket Bulkhead 438 407 18 8 Bulkhead w Flex Tube SRV7000 156 Y Orifice NG 40C SUPREME I25 IFT 582 840 Y Orifice Propane 53C 582 853...

Страница 30: ...m your dealer or distributor Stocked at Depot ITEM DESCRIPTION COMMENTS PART NUMBER Battery Pack SRV2326 134 Y Bolt Level Leg Qty 4 req 2073 162 24 Y Mineral Wool 050 721 RC400 Remote SRV2326 110 Y Sc...

Страница 31: ...__________________________________________________ ________________________________________________________________________________ DO NOT DISCARD THIS MANUAL NOTICE Leave this manual with party respo...

Отзывы: