![HEAT GLO PROV-I30-IPI Скачать руководство пользователя страница 8](http://html1.mh-extra.com/html/heat-glo/prov-i30-ipi/prov-i30-ipi_installation-manual_2115846008.webp)
8
Heat & Glo • SUPREME-I25-IFT, SUPREME-I30-IFT, SUPREME-I35-IFT Installation Manual • 2532-980 Rev. E • 5/19
3
Appliance / Fireplace Requirements and Clearances
A. Appliance/Decorative Front Dimension Diagrams
Dimensions are actual appliance dimensions. Use for reference only. For addditional clearances refer to Sections 3.D and 3.E.
Figure 3.1 Appliance Dimensions
*Note:
Location G is the appliance depth measurement, for installation depth reference Location E on
Figure 3.9.
MODEL DIMENSIONS
Location
25 in.
30 in.
35 in.
IN
MM
IN
MM
IN
MM
A
14-5/8
372
19-5/8
499
24-5/8
626
B
26-1/8
664
31-1/8
791
36-1/8
918
C
22-1/2
572
27-1/2
699
32-1/2
826
D
12-7/16
316
15-15/16
405
19-3/8
492
E
17-1/16
433
20-3/4
527
24
610
F
16-5/8
422
20-1/8
511
23-5/8
600
G*
14-1/2
368
14-1/2
369
14-1/2
368
H
7-5/16
186
9-13/16
249
12-5/16
313
I
15
381
18-15/16
481
21-7/16
545
F
K
J
GAS LINE
ACCESS
C
D
E
R
I
A
H
B
G
O
N
P
Q
ELECTRICAL
ACCESS
L
M
MODEL DIMENSIONS
Location
25 in.
30 in.
35 in.
IN
MM
IN
MM
IN
MM
J
5-11/16
144
5-11/16
144
5-11/16
144
K
5-7/8
149
5-7/8
149
5-7/8
149
L
9
229
9
229
9
229
M
8-3/4
222
8-3/4
222
8-3/4
222
N
2-1/8
54
2-1/8
54
2-1/8
54
O
4-1/16
103
4-1/16
103
4-1/16
103
P
5-3/4
146
5-3/4
146
5-3/4
146
Q
8-3/4
222
8-3/4
222
8-3/4
222
R
2-7/16
62
2-7/16
62
2-7/16
62
TOP VIEW
LEFT SIDE
RIGHT SIDE
FRONT VIEW