3.4 Flue Connection
3.4.1 General notes
This appliance may be installed with a roof termination with rigid or flexible pipes, or in a masonary chimney
class 1 or class 2 and without lining the flue. The flue system must be constructed from the appliance upwards,
with all joints being fully locked and sealed using the Heat Design specified parts.
3.4.2 Timber Frame Construction
Whilst it is possible to install room-sealed appliances in timber frame properties, great care needs to be taken
to ensure that the flue assembly does not interfere with the weatherproofing qualities of any outer wall which it
may penetrate. Before attempting this work, it is advisable to consult with a qualified installer.
3.4.3 Carport or Building Extension
Note: A covered passageway should not be treated as a carport. Flues should not be sitedin a covered
passageway between properties.