background image

 

 

Revised 20-06-13 

 

Spar

e

 Part

s

  

 

    

Component  

Causeway  16  
Boiler  

Causeway  25  
Boiler  

Causeway  15i  
Boiler  

01   Door  Glass  

Y1WX01A  

Y1WXF25B01A   Y1WX01A  

02   Glass  Brackets  and  Screws  

Y1WXFB02A  

Y1WXF25B02A   Y1WXFB02A  

03   Door  Handle  assembly  

Y1WXB03A  

Y1WXB03A  

Y1WXB03A  

04   Coalcatcher  

Y1WXF16B04A   Y1WXF25B04A   Y1WXF15I04A  

08   Riddle  Grate  

Y1HDD09E  

Y1HDD10E  

Y1HDD09E  

09   Grate  for  Riddle  Grate  

Y1WXF16B12A   Y1WXF25B12A   Y1WXI16B12A  

12   Riddle  Grate  Handle  

Y1HDF06D16E  

Y1HDF06X15E  

Y1HDF06D15E  

13   Riddle  Grate  Bar  

Y1WXF16B16A   Y1WXF16B16A   Y1WXI15B16A  

16   Baffle  Plate  

Y1WXF16B19A   Y1WXF25B19A   Y1WXI15B19A  

18   Airwash  slider  plates  

Y1WXFB21A  

Y1WXF25B21A   Y1WXFB21A  

19   Airwash  Housing  

Y1WXFB19A  

Y1WXF25B22A   Y1WXFB19A  

22   Ashpan  

Y1WXF16B28A   Y1WXF25B28A   Y1WXI15B28A  

24   Stove  Tool  

Y1WX30A  

Y1WX30A  

Y1WX30A  

25   Ashpan  Tool  

Y1WX31A  

Y1WX31A  

Y1WX31A  

26   Door  

Y1WX32A  

Y1WXF25B32A   Y1WX32A  

27   Primary  Air  Control  including  handle  

Y1WX33A  

Y1WXF25B33A   Y1WX33A  

42   Airwash  Handle  

Y1WX49A  

Y1WX49A  

Y1WX49A  

44   Door  Hinge/Pin  

Y1WX51A  

Y1WX51A  

Y1WX51A  

53   Door  Latch  roller  

Y1WX61A  

Y1WX61A  

Y1WX61A  

64   Thermostat  

Y1WX72A  

Y1WX72A  

Y1WX72A  

65   thermostat  knob  

Y1WX73A  

Y1WX73A  

Y1WX73A  

 

 
 
 

G rat

e

 A

ss

e

mbly 

 

 

 

08 

09 

13 

12 

04 

Содержание Causeway 15i

Страница 1: ...g Instructions Please hand these instructions to the stove user when the installation is complete Leave the system ready for operation and instruct the user in the correct use of the appliance and operation of controls Installation Must be installed by a qualified plumber or suitably qualified fitter ...

Страница 2: ...al Specifications Causeway 16 Causeway 25 Causeway 15i Total Heat Output kW 16 25 4 15 1 Output to Water kW 11 1 18 1 11 8 Output to room kW 4 9 7 3 3 3 Efficiency 75 73 5 73 5 Refuel Period hr 1 1 1 Safe Distance to Combustibles Sides mm 100 100 350 Safe Distance to Combustibles Top mm 200 200 550 Flue Outlet Size Inch Maximum Boiler Operating Pressure bar 1 4 1 4 1 4 Fig 1 Causeway 16 and Causew...

Страница 3: ...er stoves Heat Design cannot accept responsibility for any fault arising through incorrect installation Fig 3 Packaging Fig 4 Remove all packaging Fig 5 Causeway 16 boiler Fig 6 Causeway 25 boiler Fig 7 Causeway 15i boiler stove components stove components stove components Remove the packaging around the stove and upon opening the door remove contents as shown above Carefully remove the straps and...

Страница 4: ...llar to the top of the stove using the screws washers and nuts provided There is no need to fit a flue collar to the Causeway insert stove Fig 8 Blanking plate and collar To fit the Baffle Insert the baffle as shown in fig 10 with the chamfers to the bottom and back of the stove and ensuring that the bottom of the baffle is sitting on the baffle angles and hinge the baffle forward so that it sits ...

Страница 5: ...Revised 20 06 13 Fig 12 Stove Controls Fig 13 Thermostat Door Handle Riddle Grate Control Secondary Air Control Airwash Primary Air Control Thermostat Control Thermostat Damper ...

Страница 6: ...bility of disturbing any asbestos in the course of installation then please seek specialist guidance and use appropriate protective equipment Metal Parts When installing or servicing this stove care should be taken to avoid the possibility of personal injury Please note Any white deposits on the stove joints are caused by humidity reacting with the joint sealant These deposits may be brushed off a...

Страница 7: ...utomatically regulate the water output temperature and prevent water overheating in the boiler It is recommended to initially set the thermostat to half open and adjust as deemed necessary after the first few times of use to achieve the desired output from the stove Chimney The chimney height and the position of the chimney terminal should conform to Building Regulations Check that the chimney is ...

Страница 8: ... chimney flue are sealed and made airtight This appliance is not suitable for installation in a shared flue system Both the chimney and flue pipe must be accessible for cleaning and if ANY parts of the chimney cannot be reached through the stove with baffle removed a soot door must be fitted in a suitable position to enable this to be done Material Clearances The stove can be recessed in a suitabl...

Страница 9: ...Revised 20 06 13 Boiler Connection ...

Страница 10: ...uch as a neutralizer When fitting this type of system the neutralizer manufacturer s instructions must be followed Do Fit an open cold feed and header expansion tank with separate cold feed and vent pipes The cold feed and vent pipes must be unvalved The open vent pipe should have a diameter of 22mm and rise continuously from the boiler The gravity circuit should connect to a domestic indirect hot...

Страница 11: ... To prevent boiler corrosion due to condensation it is necessary to maintain the return water temperature above 45 C This can be achieved by the use of a LOWLIMIT thermostat on the return pipe from the hot water cylinder close to the boiler The thermostat should make on temperature rise preventing the circulating pump from operating until the gravity circuit is up to temperature Commissioning and ...

Страница 12: ...rning This appliance will be hot when In operation and due care should be taken When operating the controls Air Controls Primary Air Primary air is controlled via a sliding control on the bottom of the door This provides a conventional air draught to the bed of the fire The primary air intakes can be adjusted to give the best possible results when burning different fuels Secondary Air 7KH FDVW LUR...

Страница 13: ...Log Length Maximum Log Lengths Causeway 16 Boiler Stove 440mm Causeway 16 Boiler Stove 500mm Causeway 15i Boiler Stove 440mm Lighting the Stove We recommend that you have two or three small fires before you operate your stove to its maximum heat output This is to allow the paint to cure in steadily and to give a long service life of the paint finish During this curing in process you may notice an ...

Страница 14: ...e Remove the baffle and inspect the inside of the stove and the flue ways and ensure they are 100 clear after a period of disuse for example if the stove is not used during the warmer periods of the year Also set the air controls to 50 to keep the appliance ventilated and stop the build up of any moisture inside Frozen System If there is any possibility that the water system may be frozen do not a...

Страница 15: ...er persistent fume emission is potentially dangerous and must not be tolerated If fume emission does persist then the following immediate action should be taken 1 Open doors and windows to ventilate room and then leave the premises 2 Let the fire out 3 Check for flue or chimney blockage and clean if required 4 Do not attempt to re light the fire until the cause of the fume emission has been identi...

Страница 16: ...ct failure 6 Where can I get spare parts Your local Heat Design Stove retailer will be pleased to supply spare parts and to provide any other information you require 7 Can the doors be left open while burning For safety and heat efficiency the doors should remain closed at all times 8 Why is the stove smoking when lit A smoking stove can be caused by a flue with back draught problems A qualified f...

Страница 17: ...le Grate Bar Y1WXF16B16A Y1WXF16B16A Y1WXI15B16A 16 Baffle Plate Y1WXF16B19A Y1WXF25B19A Y1WXI15B19A 18 Airwash slider plates Y1WXFB21A Y1WXF25B21A Y1WXFB21A 19 Airwash Housing Y1WXFB19A Y1WXF25B22A Y1WXFB19A 22 Ashpan Y1WXF16B28A Y1WXF25B28A Y1WXI15B28A 24 Stove Tool Y1WX30A Y1WX30A Y1WX30A 25 Ashpan Tool Y1WX31A Y1WX31A Y1WX31A 26 Door Y1WX32A Y1WXF25B32A Y1WX32A 27 Primary Air Control including...

Страница 18: ...Revised 20 06 13 ...

Страница 19: ...Revised 20 06 13 ...

Страница 20: ...Revised 20 06 13 Heat Design 30 60 Hawthorn Road Western Industrial Estate Dublin 12 Ireland ...

Отзывы: