![Heat Controller VMH C Series Скачать руководство пользователя страница 38](http://html1.mh-extra.com/html/heat-controller/vmh-c-series/vmh-c-series_service-manual_2115786038.webp)
38
Service Manual
VMH 30, 36 SerieS
Heat Controller
36
9.2.7 High temperature protection of compressor top diagnosis and solution.
Yes
Yes
No,
Charge refrigerant
Is abnormality the same
after gas charging?
Replace the outdoor PCB.
No
Yes
Is protector normal?
No
No
Is the connection
good
There is a blockage (Such as capillary or welded points of the pipes.)
Is refrigerant circulation
volume normal?
Replace it
Reconnect it
Does compressor operate?
37
9.2.8 Inverter compressor drive error diagnosis and solution.
Yes
Replace the outdoor PCB
Replace inverter compressor.
Reconnect and retry
No
No
Is the connection of the compressor
good? Is the wiring sequence right? The
voltage range proper?