Figure 5.2 SL Pipe Effective Length
Pipe
SL-06D 5-3/4
SL-09D 8-3/4
SL-12D 11-3/4
SL-12/17D 11-3/4 to 16-3/4
SL-17/24D 16-3/4 to 23-3/4
SL-24D 23-3/4
SL-36D 35-3/4
SL-48D 47-3/4
Length/Inches
5
Vent Information and Diagrams
Fire Hazard.
Explosion Risk.
Asphyxiation Risk.
Do NOT connect this gas appliance to a chimney
fl
ue serving a separate solid-fuel or gas burning
appliance.
• Vent this appliance directly outside.
• Use separate vent system for this appliance.
May impair safe operation of this appliance or
other appliances connected to the
fl
ue.
CAUTION
ALL vent con
fi
guration speci
fi
cations MUST be followed.
• This product is tested and listed to these speci
fi
cations.
• Appliance performance will suffer if speci
fi
cations are
not followed.
B. Use of Elbows
Diagonal runs have both vertical and horizontal vent
aspects when calculating the effects. Use the rise for the
vertical aspect and the run for the horizontal aspect (see
Figure 5.1).
Two 45
0
elbows may be used in place of one 90
0
elbow.
On 45
0
runs, one foot of diagonal is equal to 8.5 inches
horizontal run and 8.5 inches vertical run. A length of
straight pipe is allowed between two 45
0
elbows (see
Figure 5.1).
Figure 5.1
A. Vent Table Key
The abbreviations listed in this vent table key are used in
the vent diagrams.
C. Measuring Standards
Vertical and horizontal measurements listed in the vent
diagrams were made using the following standards.
1. Pipe measurements are shown using the effective length
of pipe (see Figure 5.2).
2. Measurements are made from the appliance outer wrap,
not from the standoffs.
3. Horizontal terminations are measured to the outside
mounting surface (
fl
ange of termination cap) (see Figure
4.1).
4. Vertical terminations are measured to bottom of termina-
tion cap.
5. Horizontal pipe installed level with no rise.
Effective
Height/Length
Symbol
Description
V
1
First section (closest to appliance) of vertical length
V
2
Second section of vertical length
H
1
First section (closest to appliance) of horizontal length
H
2
Second section of horizontal length
Horizontal
Vertical
8-1/2 in.
8-1/2 in.
12 in.