Heat & Glo • SL-550/750TR-E, SL-550/750/950TR-IPI-E Installation Manual • 2118-910 Rev. C • 4/16
Figure 4.15
Top Vent - Vertical Termination - (continued)
Four Elbows
Note
: There MUST be a 25%
reduction in total H when using
fl
ex vent except when using the
simple up and out installation.
See Figure 4.6.
V
1
MIN.
H
1
MAX.
V
2
MIN.
H
2
MAX.
V
3
MIN.
1-1/2 ft.
457 mm
4 ft.
1.2 m
4 ft.
1.2 m
4 ft.
1.2 m
3-1/2 ft.
1.0 m
V
1
+ V
2
+ V
3 +
H
1
+ H
2
Maximum= 40 ft. (12.2 m)
V
1
H
1
V
2
V
3
H
2
Note
: Use SLP Series
components only.