Heat & Glo • RED60 • 2159-900 Rev. B • 12/09
43
REPLACEMENT PARTS
Replacement parts can be obtained from your dealer. Re-
pair of the Power Vent should only be done by a qualifi ed
service person.
1. ACCESS TO THE VACUUM SWITCH, TEFLON TUB-
ING, AND FAN MOTOR:
A. Turn power to off. Remove end cap by removing the
four (4) sheetmetal screws. See Figure 7.40.
B. Unplug the two wires connected to the vacuum
switch and the two wires connected to the fan motor.
C. Loosen and remove the nut for the right angle connector
and carefully pull back the cable to remove the four (4)
wires from the power vent assembly.
D. With the cable loosened from the power vent assembly,
remove the sheetmetal screws used to secure the power
vent assembly in place. Firmly support the assembly to
prevent the unit from falling after the sheetmetal screws
have been removed. See Figure 7.41.
E. Remove the sheetmetal screws from the 10-1/2 in.
diameter pipe and remove the inner ring from inside
the collar. See Figure 7.42
IMPORTANT:
Take special note of the orientation of the
two part assembly. The inner ring must be returned to its
original position for correct Power Vent operation.
F. Remove the wire mesh that is covering the exhaust port
hole by removing the 4 sheetmetal screws.
G. Bend the metal guide plate at the exhaust port hole out
and through the hole on the 10-1/2 in. diameter collar.
See Figure 7.43.
END CAP
Figure 7.40
REMOVE
SCREWS
SUPPORT WHEN
REMOVING
Figure 7.41
REMOVE SCREWS
INNER RING
Figure 7.42
METAL GUIDE PLATE
MUST BE IN POSITION
AS SHOWN
Figure 7.43
Note:
On some caps, the metal guide plate is attached to the
wire mesh and will slide out with the mesh.
H. Slide the blower assembly out of the 10-1/2 in. diameter
collar for maintenance or replacement.