background image

Heat & Glo  •  SLR •  2143-900 Rev. B  •  7/08  

66

Service Parts

SLR

Beginning Manufacturing Date:  July 2008

Ending Manufacturing Date: ______ 

Valve Assembly Diagram/ Parts List

IPI Valve Assembly

1

2

3

4

5

6

7

8

9

10

11

IMPORTANT: THIS IS DATED INFORMATION. When requesting service or replacement 
parts for your appliance please provide model number and serial number. All parts listed 
in this manual may be ordered from an authorized dealer.

Stocked 

at Depot

ITEM

DESCRIPTION

COMMENTS

PART NUMBER

1

Pilot Assembly NG 

2090-012

Y

Pilot Assembly LP

2090-013

Y

2

Valve Bracket 

2118-104

N

3

Flex Ball Valve Assembly  

302-320A

Y

4

Valve NG 

593-500

Y

Valve LP

593-501

Y

5

Module

593-592

Y

6

Thermostat Wire Assembly 

2118-170

Y

7

Module Wire Assembly

593-590A

Y

8

3 Volt Transformer  

593-593A

Y

9

Bulkhead W/Flex Tube

7000-156

Y

10

Battery Pack 

593-594A

Y

11

Orifi ce NG (#42C)

582-842

Y

Orifi ce LP (.057C)

582-057

Y

Jumper Wires 21 in

2012-206

Содержание Cosmo SLR

Страница 1: ...rating plate Installation and service of this appliance should be performed by qualified personnel Hearth Home Technologies suggests NFI certified or factory trained professionals or technicians super...

Страница 2: ...on Model Number Heat Glo a of Hearth Home Technologies Inc 20802 Kensington Boulevard Lakeville MN 55044 brand Not for use with solid fuel Ne doit pas entre utilise avec un combustible solide This app...

Страница 3: ...B Design and Installation Considerations 15 C Tools and Supplies Needed 15 D Inspect Appliance and Components 15 5 Framing and Clearances A Selecting Appliance Location 16 B Constructing the Applianc...

Страница 4: ...Setup A Remove Fixed Glass Assembly 54 B Remove the Shipping Materials 54 C Clean the Appliance 54 D Accessories 54 E Rock Media Instructions 55 F Fixed Glass Assembly 57 G Install the Mesh 57 H Air...

Страница 5: ...reafter are NOT covered by this war ranty unless expressly authorized and approved by HEAT GLO in writing 6 Any damages caused by environmental conditions inadequate ventilation or drafting caused by...

Страница 6: ...not be factored as primary heat in residential heating calculations D High Altitude Installations NOTICE If the heating value of the gas has been reduced these rules do not apply Check with your loca...

Страница 7: ...g appliance or equipment The sign shall read in print size no less than one half 1 2 in in size GAS VENT DIRECTLY BELOW KEEP CLEAR OF ALL OB STRUCTIONS Inspection The state or local gas inspector of t...

Страница 8: ...surfaces are hot during operation AND cool down Hot glass will cause burns DO NOT touch glass until it is cooled NEVER allow children to touch glass Keep children away CAREFULLY SUPERVISE children in...

Страница 9: ...e For more information refer to the instructions supplied with your decorative door or front F Remote Controls Wall Controls and Wall Switches Follow the instructions supplied with the control install...

Страница 10: ...vier than air and will settle on the floor WHAT TO DO IF YOU SMELL GAS DO NOT try to light any appliance DO NOT touch any electric switch do not use any phone in your building DO NOT CONNECT 110 VAC T...

Страница 11: ...used by the curing of materials from manufacturing Odor may also be released from finishing materials and adhesives used near the fireplace These circumstances may require additional curing related to...

Страница 12: ...factors Control compartment burner and circulating air passageway of the fireplace must be kept clean CAUTION Risk of Burns The fireplace should be turned off and cooled before servicing When properl...

Страница 13: ...ician Tools needed Protective gloves vacuum cleaner dust cloths Vacuum and wipe out dust cobwebs debris or pet hair Use caution when cleaning these areas Screw tips that have penetrated the sheet meta...

Страница 14: ...PENETRATION FRAMING SECTION 8B VERTICAL TERMINATION CAP SECTION 10 NON COMBUSTIBLE ROOF FLASHING MAINTAINS MINIMUM CLEARANCE AROUND PIPE SECTION 10 STORM COLLAR SECTION 10 VENT PIPE SECTIONS 7 8 CEIL...

Страница 15: ...rts could impair safe operation DO NOT install damaged in complete or substitute components Keep appliance dry C Tools and Supplies Needed Before beginning the installation be sure that the following...

Страница 16: ...e Actual installation may vary due to individual design preference 1 IN A E A B C TOP VENT ONE 900 ELBOW ALCOVE INSTALLATION D TOP VENT ONE 90 ELBOW B F Figure 5 1 Appliance Locations A B C D E F Inch...

Страница 17: ...caulked with high temp caulk or stuffed with unfaced in sulation If the appliance is being installed on a cement slab a layer of plywood may be placed underneath to prevent conducting cold up into the...

Страница 18: ...ptable on both sides of opening Figure 5 6 Non Combustible Mantel Leg or Wall Projections Acceptable on both sides of opening Combustible Mantel Legs Or Wall Projections Extending Past The Face Of The...

Страница 19: ...Heat Glo SLR 2143 900 Rev B 7 08 19 1 2 in SHEETROCK 3 1 2 in 1 in AIR SPACE NON COMBUSTIBLE BOARD SHIPPED WITH APPLIANCE 1 9 16 in Figure 5 8 Non Combustible Zone...

Страница 20: ...DISCHARGE OPENING 6 6 Termination Locations Fire Risk Maintain vent clearance to combustibles as specified DO NOT pack air space with insulation or other materials Failure to keep insulation or other...

Страница 21: ...imensions specified for vinyl or non vinyl siding and soffits 1 There must be 3 feet minimum between termination caps 2 All mechanical air intakes within 10 feet of a termination cap must be a minimum...

Страница 22: ...d horizontal measurements listed in the vent diagrams were made using the following standards Pipe measurements are shown using the effective length of pipe see Figure 7 2 Measurements are made from t...

Страница 23: ...or other combustibles between ceiling firestops ALWAYS maintain specified clearances around venting and firestop systems Install wall shield and ceiling firestops as specified Failure to keep insulat...

Страница 24: ...nimum H1 H2 MAXIMUM SLR 90 Elbow 1 ft 305 mm 1 ft 305 mm 2 ft 610 mm 2 ft 610 mm 4 ft 1 2 m 3 ft 914 mm 6 ft 1 8 m 4 ft 1 2 m 14 ft 4 3 m H H1 MAX 14 ft 4 3 m V H H1 MAX 40 ft 12 2 m Note There MUST b...

Страница 25: ...ft 1 8 m 1 ft 305 mm 10 ft 3 0 m 2 ft 610 mm 12 ft 3 7 m 3 ft 914 mm 14 ft 4 3 m H1 H2 MAX 14 ft 4 3 m V1 V2 H1 H2 MAX 40 ft 12 2 m No specific restrictions on this value EXCEPT V1 V2 H cannot exceed...

Страница 26: ...se SLP Series components only V Minimum H1 H2 H3 MAXIMUM SLR NG ONLY 90 Elbow ft mm 3 ft 914 mm 15 ft 4 6 m H1 H2 H3 MAX 15 ft 4 6 m V1 H1 H3 H2 Note There MUST be a 25 reduction in total H when using...

Страница 27: ...screws to secure vent restric tor to firebox heat shield See Figure 7 9 Exhaust restrictors are recommended for these vertically terminated products which have excessive draft Exhaust restrictors will...

Страница 28: ...Minimum 90 Elbow 2 ft 610 mm 1 ft 152 mm 3 ft 914 mm 2 ft 457 mm 5 ft 1 5 m 3 ft 914 mm 7 ft 2 1 m 4 ft 1 1 m 15 ft 4 6 m H MAX 15 ft 4 6 m V1 V2 H MAX 40 ft 12 2 m No specific restrictions on this va...

Страница 29: ...m V2 V1 V2 Minimum 90 Elbow 1 ft 305 mm 1 ft 305 mm 2 ft 610 mm 2 ft 610 mm 4 ft 1 2 m 3 ft 914 mm 6 ft 1 8 m 4 ft 1 2 m 14 ft 4 3 m H MAX 14 ft 4 3 m V1 V2 H1 H2 MAX 40 ft 12 2 m No specific restrict...

Страница 30: ...mponents only Note There MUST be a 25 reduction in total H when using flex vent except when using the simple up and out installation see Figure 5 3 V1 MIN H1 MAX V2 MIN H2 MAX V3 MIN 1 1 2 ft 457 mm 4...

Страница 31: ...gure 8 2 Wall Penetration Shows center of vent framing hole for top venting The center of the hole is one 1 in 25 4 mm above the center of the horizontal vent pipe Figure 8 1 Horizontal Venting Cleara...

Страница 32: ...n installed with a attic insulation shield It must be under joists between floors that are not insulated Refer to Figure 8 5 Secure with three fasteners on each side WARNING Risk of Fire DO NOT pack i...

Страница 33: ...aintain air space clearance Figure 8 6 Attic Insulation Shield BEND ALL TABS INWARD 90 TO MAINTAIN CLEARANCE AND PREVENT INSULATION FROM FALLING INSIDE INSERT 3 SCREWS BEND 3 TABS OUTWARD TO FASTEN TO...

Страница 34: ...9 2 Elbow Shield Shown Installed If venting with a 90 degree elbow directly off of the top of the appliance the elbow heatshield must be repositioned as shown in Figure 9 2 If venting vertically or us...

Страница 35: ...tabs are provided to secure the appliance to the framing members Bend out nailing tabs on each side Place the appliance into position Keep nailing tabs flush with the framing Level the appliance from...

Страница 36: ...ly fitted and locked into the preceding component Commercial Multi family Multi level exceeding two sto ries or High Rise Applications For Installation into a commercial multi family multi level excee...

Страница 37: ...ipe section and the outer flue of the slip section over the outer flue of the pipe section See Figure 10 3 Slide together to the desired length Figure 10 3 Slip Section Pilot Holes Figure 10 4 Screws...

Страница 38: ...small hole through the ceiling and roof at this point Locate the hole and mark the outline of the cathedral ceiling support box on the outside roof Remove shingles or other roof covering as necessary...

Страница 39: ...Figure 10 12 CAULK NOTICE Failure to properly caulk the roof flashing could cause water entry Caulk the gap between the roof flashing and the outside diameter of the pipe Caulk the perimeter of the f...

Страница 40: ...r flue with water and slide the flashing down It may be necessary to trim the top shingles around the base of the rubber boot to ensure a good fit Draw around flashing remove Apply silicone sealant to...

Страница 41: ...Risk of Fire To prevent overheating and fire heat shields must extend through the entire wall thick ness DO NOT remove the heat shields attached to the wall shield firestop and the horizontal terminat...

Страница 42: ...cap base Flash and seal as appropriate for siding material at outside edges of cap When installing a horizontal termination cap follow the cap location guidelines as prescribed by current ANSI Z223 1...

Страница 43: ...ensed plumber or gas fitter Fire Risk Explosion Hazard High pressure will damage valve Disconnect gas supply piping BEFORE pressure testing gas line at test pressures above 1 2 psig Close the manual s...

Страница 44: ...nsure adequate ventilation Ensure there are no ignition sources such as sparks or open flames Light the appliance It will take a short time for air to purge from lines When purging is complete the app...

Страница 45: ...es not included into the battery pack before use NOTICE Batteries should not be placed in the battery pack while using the transformer Remove batteries before using the transformer and unplug the tran...

Страница 46: ...ASSEMBLY WIRES TO BROWN ORANGE GREEN VALVE WHITE ORANGE IGNITION MODULE 3 VAC INTERMITTENT PILOT IGNITOR HOT NEUTRAL I S GROUND TO FIREPLACE CHASSIS NOTE 1 Ignition module valve pilot and wall switch...

Страница 47: ...f Materials in a Vertical Tube Furnace at 750 C and UL763 shall be considered non combustible materials Setting the Fireplace into the Framing Unlikemanytraditional single sidedHeat Glofireplaces this...

Страница 48: ...ch as screws or nails are not permitted in some locations See Figure 13 4 It is acceptable to pre drill holes and use self tapped screws in the factory installed non combustible board which may be use...

Страница 49: ...d CAN NOT be sealed with a combustible drywall tape Depending upon the final finishing method use a minimum rated 300 degree sealant drywall compound or thin set to seal the side and top joints Figure...

Страница 50: ...liance Figure 13 10 Combustible Mantel Leg or Wall Projections Acceptable on both sides of opening Figure 13 11 Non Combustible Mantel Leg or Wall Projections Acceptable on both sides of opening Combu...

Страница 51: ...roved to be installed in an inside fit application with up to 4 in of non combustible material up to 4 in thick See Figure 13 14 Figure 13 15 and Figure 13 16 Please refer to the appropriate section f...

Страница 52: ...e left and right sides flush with the factory installed non combustible board See Figure 13 15 WARNING Risk of Fire The Martini decorative Front is not approved for inside fit installations DO NOT ins...

Страница 53: ...O NOT operate this appliance without a decorative front in place D Decorative Fronts TONIC DECORATIVE FRONT TN SLR MARTINI DECORATIVE FRONT MT SLR Figure 13 17 Tonic Decorative Front Figure 13 18 Mart...

Страница 54: ...may have accumulated inside the firebox or underneath in the control cavity D Accessories Install approved accessories per instructions included with accessories Install approved accessories per in st...

Страница 55: ...ilot assembly No rock media may be placed in the outlined area Continue to place an even amount of Rock Media over the entire base pan DO NOT install Rock Media in between the tracks over the entire l...

Страница 56: ...e pilot cover See Figures 14 6 and 14 4 Figure 14 5 Remove Screw 4 The rock media placement jig must remain in place while media is placed on the basepan and around the pilot bracket 5 Remove the rock...

Страница 57: ...move the decorative front 2 Locate the two spring latches that are on the upper left and right of the fireplace 3 Use both index fingers to release spring latches See Figure 14 3 4 Allow glass to tilt...

Страница 58: ...r ing configuration or wiring harness Remove and reinstall the wiring harness that plugs into module Verify there is a tight fit Verify pilot assembly wiring to module Re move and verify continuity of...

Страница 59: ...orifice is installed and gas inlet is set to pressure specifications Clean flame sensing rod with emery cloth to remove any contaminants that may have accumulated on flame sensing rod c Module is not...

Страница 60: ...L ACCESS GAS LINE ACCESS LEFT VIEW FRONT VIEW RIGHT VIEW NON COMBUSTIBLE ZONE PROVIDED WITH UNIT 1 INCH STANDOFF T U Figure 16 1 Appliance Dimensions Location Inches Millimeters K 1 25 L 37 3 4 959 M...

Страница 61: ...14 in 356 mm COOL ADD Cap Shield 11 5 8 in 295 mm 5 3 4 in 146 mm 7 1 8 in 181 mm 12 1 8 in 308 mm PVK 80 For use with IPI and DSI appliances only DVP BEK2 DVP HPC Cap Brick Extension 13 7 8 in 352 m...

Страница 62: ...Effective Height Length SLP PIPE SLP HVS Horizontal Pipe Support RF4 8 Roof Flashing SLP FS Ceiling Firestop SLP WS Wall Shield Firestop B Vent Components Diagrams continued Figure 16 5 SLP Series Ven...

Страница 63: ...k SLP WT BK Wall Thimble Black B Vent Components Diagrams continued Figure 16 6 SLP Series Vent Components 13 in 330 mm 15 in 381 mm 8 1 8 in 206 mm 10 7 8 in 276 mm 10 1 2 in 267 mm 3 87 Effective Le...

Страница 64: ...t Glo SLR 2143 900 Rev B 7 08 64 C Service Parts SLR Beginning Manufacturing Date July 2008 Ending Manufacturing Date ______ Service Parts Diagram Part number list on following page 6 10 9 7 8 5 4 3 1...

Страница 65: ...43 115 N 6 Burner NG 2143 007 Y Burner LP 2143 008 Y 7 Pilot Bracket 2143 123 n 8 Glass Door Assembly GLA SLR Y 9 Junction Box 4013 021 Y 10 Lower Cover Panel 2143 103 N 12 in Pipe SLP12 N Black Rock...

Страница 66: ...arts listed in this manual may be ordered from an authorized dealer Stocked at Depot ITEM DESCRIPTION COMMENTS PART NUMBER 1 Pilot Assembly NG 2090 012 Y Pilot Assembly LP 2090 013 Y 2 Valve Bracket 2...

Страница 67: ...______________________________________________ ________________________________________________________________________________ This product may be covered by one or more of the following patents Unit...

Отзывы: