background image

Heat & Glo  •  Soho-CE  •  2111-900 Rev. D  •  6/07

19

B.  Installing Firestops and Horizontal Termination Cap

Do NOT connect a pipe section to a termination cap without using 
the telescoping fl ue section found on the termination cap.

NOTE: 

Where required, an exterior wall fl ashing is available.

When penetrating a brick wall, a brick extension kit is avail-
able for framing the brick.

Installing the Horizontal Termination Cap

Flue termination must not be recessed in the wall. Siding 
may be brought to the edge of the cap base. 

Flash and seal as appropriate for siding material at outside 
edges of cap.

For Horizontal Runs -

 Wall shield fi restops are 

REQUIRED

 

on both sides of a combustible wall through which the fl ue 
passes.

NOTE: Model SLK-01TRD does not need an exterior 
wall shield fi restop on an exterior combustible wall as 
the shield is built into this termination cap assembly.

To install wall shield fi restops for horizontal runs that pass 
through either interior or exterior walls:

Cut a 25.4 cm x 25.4 cm hole for SL-D-series pipe. The 
center of the framing hole is 2.54 cm above the center of 
the horizontal fl ue pipe.

•  Position the wall shield fi restops on both sides of the 

hole previously cut and secure the wall shield fi restops 
with nails or screws. 

•  The heat shields of the wall shield fi restops 

MUST BE

 

placed towards the top of the hole.

• Continue the fl ue run through the wall shield fi restops.

Figure 8.2  Hole and Flue Pipe

Figure 8.3  Heat Shield, Interior & Exterior Wall Shield Firestops

TRIM HEAT
SHIELD IF TOO
LONG, ADD TO
SHIELD IF TOO
SHORT

WALL SHIELD

FIRESTOP

(INTERIOR)

HEAT SHIELD

WALL SHIELD

FIRESTOP

(EXTERIOR)

Fire Risk.   
Explosion Risk.

Do NOT pack insulation or other 
combustibles between fi restops.

•  ALWAYS maintain specifi ed clearances around venting 

and fi restop systems.

• Install fi restops as specifi ed.
Failure to keep insulation or other material away from fl ue 
pipe may cause fi re.

2.54 cm

25.4 cm

25.4 cm

FLUE PIPE

PIPE CENTER LINE

FRAMED HOLE CENTER LINE

WARNING

Fire Risk
Exhaust Fumes Risk
Impaired Performance of Appliance 

• Ensure fl ue components are locked together correctly.
•  Pipe may separate if not properly joined.

WARNING

WARNING

Содержание Balanced Flue Gas Fireplace SOHO-CE

Страница 1: ...hildren and adults to hazards of high temperatures Do NOT operate with protective barriers open or removed Keep clothing furniture draperies and other combustibles away Glass and other surfaces are ho...

Страница 2: ...in safety reliability and efficiency As the owner of a new appliance you ll want to read and carefully follow all of the instructions contained in this Installer s Guide Pay special attention to all...

Страница 3: ...Appliance Preparation A Securing and Leveling the Appliance 17 8 Installing Flue Pipe A Assembly of Flue Sections 18 B Installing Firestops and Horizontal Termination Cap 19 C Install Roof Flashing a...

Страница 4: ...E 136 Stan dard Test Method for Behavior of Materials in a Vertical Tube Furnace at 750 C shall be considered non com bustible materials C Combustible Materials Specification Materials made of or surf...

Страница 5: ...components and trim doors are shipped in separate packages The logs are packaged separately inside the fireplace and must be field installed Report to your dealer any parts damaged in shipment particu...

Страница 6: ...ng and Clearances Note Illustrations reflect typical installations and are FOR DESIGN PURPOSES ONLY Illustrations diagrams are not drawn to scale Actual installation may vary due to individual design...

Страница 7: ...ding codes MUST be checked Chases should be constructed in the manner of all out side walls of the home to prevent cold air drafting prob lems The chase should not break the outside building envelope...

Страница 8: ...12 to 20 12 2 29 Over 20 12 to 21 12 2 44 Figure 4 1 Figure 4 2 Minimum height from roof to lowest discharge opening 4 4 Termination Locations Measure horizontal clearances from this surface Measure...

Страница 9: ...en on a minimum of 2 sides beneath the floor or meets Note 2 NOTE 1 On private property where termination is less than 7 feet above a sidewalk driveway deck porch veranda or balcony use of a listed ca...

Страница 10: ...90 elbow On 45 runs 30 5 cm of diagonal is equal to 21 6 centimeters horizontal run and 21 6 centimeters vertical run A length of straight pipe is allowed between two 45 elbows see Flue diagrams Figu...

Страница 11: ...Elbows V1 H1 Two Elbows V Minimum H1 H2 Maximum Elbow only Not Allowed 30 cm 91 cm 61 cm 1 8 m 91 cm 2 7 m 1 2 m 3 7 m 1 5 m 4 6 m V H1 H2 Maximum 11 9 m H1 H2 Maximum 4 6 m D Flue Diagrams One Elbow...

Страница 12: ...rizontal Termination continued Three Elbows Three Elbows V1 Minimum H1 Maximum V2 Minimum H2 Maximum 30 cm 61 cm 30 cm 61 cm 61 cm 1 2 m 61 cm 1 2 m 91 cm 1 8 m 91 cm 1 8 m 1 2 m 2 4 m 1 2 m 2 2 m V1...

Страница 13: ...ertical Termination No Elbow Figure 5 6 Figure 5 7 Two Elbows V1 11 8 m Maximum V1 V1 V2 H1 Two Elbows V1 Minimum H Maximum Elbow only 46 cm 30 cm 91 cm 61 cm 1 2 m 91 cm 1 8 m 1 2 m 2 4 m 1 8 m 4 6 m...

Страница 14: ...4 Figure 5 8 2 Vertical Termination continued Three Elbows V2 H2 V1 INSTALLED HORIZONTALLY H1 Three Elbows V1 Minimum H1 H2 Maximum 30 cm 61 cm 61 cm 91 cm 91 cm 1 5 m 1 2 m 2 1 m 1 5 m 4 3 m V1 V2 H1...

Страница 15: ...eter 2 54 cm greater than the pipe is acceptable B Wall Penetration Framing Figure 6 2 Exterior Wall Hole A B 25 4 cm Shows center of flue framing hole The center of the hole is one 2 54 cm above the...

Страница 16: ...dditional ceiling firestop is not required if attic shield is used Frame opening for attic shield Attic shield may be installed above or below ceiling see Figure 6 4 Secure with three fasteners on eac...

Страница 17: ...de to side and front to back Shim the appliance as necessary It is acceptable to use wood shims Bend out nailing tabs on each side Keep nailing tabs flush with the framing Secure the appliance to the...

Страница 18: ...e the pipe section clockwise about one quarter 1 4 turn see Figure 8 1 The flue pipe is now locked together Slide the ceramic rope ring over the first flue section and place it flush to the appliance...

Страница 19: ...ut a 25 4 cm x 25 4 cm hole for SL D series pipe The center of the framing hole is 2 54 cm above the center of the horizontal flue pipe Position the wall shield firestops on both sides of the hole pre...

Страница 20: ...sk Explosion Risk Inspect external flue cap regularly Ensure no debris blocks cap Combustible materials blocking cap may ignite Restricted air flow affects burner operation WARNING Roof Pitch H Min Me...

Страница 21: ...around the exposed pipe section and align brackets Insert a bolt provided through the brackets and tighten nut to complete storm collar assembly see Figure 8 7 Slide the assembled storm collar down th...

Страница 22: ...est all gas line points and the gas control valve prior to and after starting the gas appliance Table 1 9 9 Gas Information Natural Gas G20 Propane G31 Butane G30 Natural Gas G25 Inlet Pressure 20mbar...

Страница 23: ...system The batteries are located within the ignition module which is located under the unit A wiring diagram is shown in Figure 7 1 The battery pack requires four AA batteries not included Figure 10...

Страница 24: ...ZONE FINISH WALL MATERIAL MAY BE COMBUSTIBLE TOP AND SIDES 20 3 cm 74 cm 0 cm 0 cm 0 cm B Mantel Projections No mantels are allowed when using Studio CE fronts Risk of Fire Non combustible clearances...

Страница 25: ...l Ember material is shipped with this gas appliance To place the ember material Place small pieces of ember material on burner top around burner ports Do NOT press embers into burner ports Do NOT plac...

Страница 26: ...cating tab Step 2 Place Log 2 SRV2111 701 onto base pan such that Log 2 fits in groove of Log 1 Push it back against the left hand side locating tab Ensure burner ports are not covered by logs Step 3...

Страница 27: ...ly Replace the glass door on the appliance Pull out and latch the two glass assembly latches into the groove on the glass frame on the bottom and top edges BOTTOM LATCH GLASS ASSEMBLY Handle glass doo...

Страница 28: ...nance can cause injury or property damage Refer to the owner s information manual provided with this appliance For assistance or additional information consult a qualified installer service agency or...

Страница 29: ...settle on the floor WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance DO NOT CONNECT 240 VAC TO THE CONTROL VALVE Improper installation adjustment alteration service or maintenance can cau...

Страница 30: ...off smoke detectors Smoke and odors may be irritating to sensitive individuals CAUTION Fire Hazard Keep combustible materials gasoline and other flammable vapors and liquids clear of appliance Do NOT...

Страница 31: ...along cable D Valve Replace valve Do not over tighten E Over tightened thermocouple interrupter Replace valve and thermocouple interrupter F Receiver Replace receiver and reprogram code 5 Pilot is lit...

Страница 32: ...lass after initial 3 4 hours operation Longer operation without cleaning glass may cause a permanent white film on glass CAUTION When cleaning glass door Avoid striking scratching or slamming glass Do...

Страница 33: ...rrect as necessary Firebox 1 Inspect for paint condition warpage corrosion or perforation Sand and repaint as necessary 2 Replace appliance if firebox has been perforated Burner Ignition and Operation...

Страница 34: ...5 6 O 94 0 G 11 5 P 9 6 H 83 2 Q 5 7 I 58 6 Appliance Dimensions Table Figure 16 1 Appliance Dimensions A B C D E F G H I J K L M N O P Q GAS LINE ACCESS ELECTRICAL ACCESS 16 16 Reference Materials A...

Страница 35: ...2111 900 Rev D 6 07 35 4 5 6 7 8 9 10 11 12 1 2 3 Service Parts List Part number list on following page Log Set Assembly Service Parts Diagram SOHO CE Beginning Manufacturing Date 1 07 Ending Manufact...

Страница 36: ...Base Pan 2111 101 8 Burner Assembly N 2111 020 Burner Assembly P 2111 022 Burner Assembly B 2111 024 9 Glass Assembly GLA SOHOCE 10 Mesh Assembly 2077 011 11 Decorative Front DF SOHOCE BK 12 Module H...

Страница 37: ...024 3 Pilot Bracket 2111 123 4 Flex Tube Assembly 530 302A 5 Burner Neck Gasket 438 407 6 Valve Plate Gasket 2077 138 7 Valve Bracket 2111 186 8 Thermocouple block 2098 146 9 Valve N 2098 138 Valve B...

Страница 38: ...roduct or added thereafter are NOT covered by this war ranty unless expressly authorized and approved by HEAT GLO in writing 6 Any damages caused by environmental conditions inadequate ventilation or...

Страница 39: ...__ D Contact Information Please contact your Heat Glo dealer with any questions or concerns For the location of your nearest Heat Glo dealer please visit www heatnglo com Printed in U S A Copyright 20...

Отзывы: