Hearthstone Quality Home Heating Products, Inc ARIES 16/26/46 Series 8905, 8915, 8925
8
Specifications
NATURAL GAS SPECIFICATION CHART
INPUT
ARIES 16 VF
ARIES 26 VF
ARIES 46 VF
Input Rating BTU/Hr.
16,000
26,000
37,000
Min. Input BTU/Hr.
12,500
16,000
23,000
Orifice Size - DMS
#51
#46
#38
GAS SUPPLY
ARIES 16 VF
ARIES 26 VF
ARIES 46 VF
Manifold Pressure
4.8”w.c. / 1.2kPa
4.8”w.c. / 1.2kPa
3.9”w.c. / 1.0kPa
Min. Supply Pressure
5.5”w.c. / 1.4kPa
5.5”w.c. / 1.4kPa
5.5”w.c. / 1.4kPa
Max. Supply Pressure
10.0”w.c. / 2.5kPa
10.0”w.c. / 2.5kPa
10.0”w.c. / 2.5kPa
PROPANE (LP) SPECIFICATION CHART
INPUT
ARIES 16 VF
ARIES 26 VF
ARIES 46 VF
Input Rating BTU/Hr.
18,000
30,000
37,000
Min. Input BTU/Hr.
11,000
19,000
25,000
Orifice Size – DMS
#55
#52
#50
GAS SUPPLY
ARIES 16 VF
ARIES 26 VF
ARIES 46 VF
Manifold Pressure
10.0”w.c. / 2.5kPa
10.0”w.c. / 2.5kPa
10.0”w.c. / 2.5kPa
Min. Supply Pressure
11.0”w.c. / 2.8kPa
11.0”w.c. / 2.8kPa
11.0”w.c. / 2.8kPa
Max. Supply Pressure
13.0”w.c. / 3.3kPa
13.0”w.c. / 3.3kPa
13.0”w.c. / 3.3kPa
It is recommended that the pilot flame be turned off if the appliance will not be in use for an
extended period of time.
This appliance is equipped for use with the fuel type indicated on the rating plate. Field
conversion is not permitted.