MINIMUM CLEARANCES TO COMBUSTIBLE CONSTRUCTION
ARIES 16 VF
ARIES 26 VF
ARIES 46 VF
Fireplace to Left Side Wall - (Dimension “A”)
6”
6”
6”
Fireplace to Right Side Wall - (Dimension “A”)
6”
6”
6”
Fireplace to Corner Side Wall - (Dimension “B”)
6”
6”
6” *
Fireplace to Ceiling (Dimension “C”)
12”
12”
12”
Fireplace to Floor (Dimension “D”)
3” **
3” **
3” **
Fireplace to Rear Wall
0” ***
0” ***
0” ***
Air Space Behind Mounting Plate (Dimension “E”)
5/16”
5/16”
3/8”
Floor to Ceiling Overall Minimum Dimension
45”
42 ¼”
40 ¼”
*Optional Corner Kit not available for the ARIES VF
**The minimum required clearance to be maintained from the fireplace to combustible flooring is measured from the top
surface of carpeting, tile, etc.
***Mounting plate bosses contact the wall.