HearthSt one Quality Home Heating Products, Inc.
STOWE 8321 Gas-Fired Direct -Vent
02044-1
29
remote) to “ON”. Then set the desired
temperature.
10. Shut the gas control valve access door.
11. Plug in the fan accessory, if so equipped.
12. If T’stat was selected, set thermostat to
“ON” and set desired temperature
setting. Normally, if T’stat position was
selected, the main burner is cycled on
and off by the thermostat or the “on/off”
switch located on the bottom of the
thermostat body.
NOTE
:
When pressing/clicking the
piezoelectric spark ignition button to light
the pilot, watch through the glass (front) of
the unit. Click the igniter button until a
flame is visible at the pilot. Once the pilot is
lit, continue to press on the gas control knob
for another 20 seconds, then release.
Ascertain that the pilot is still lit by looking
through the front door. If lit, then turn the
gas control knob fully counter-clockwise to
the “ON” position. If the pilot fails to light,
or if it went out due to a premature release
of the gas control knob while depressed in
the “PILOT” position, wait 60 seconds for
the Interlock to release. Then repeat the
lighting process as described in this section
of the manual.
Once the pilot has been lit, the gas control
knob has been turned to the “ON” position,
and the ON/OFF/T’stat switch has been
turned to “ON”, the main burner should light
immediately. If you would like to use the
thermostat and it has been installed, switch
the ON/OFF/T’stat switch to thermostat.
Turn the thermostat to "ON" and set it to a
higher position so that it "calls" for heat in
order to light the main burner (i.e. turns the
unit on). Note that the thermostat controls
the on/off cycling of the main burner, but
the pilot remains lit regardless of the
thermostat setting. The only way to turn the
pilot off is to turn the gas control knob fully
clockwise to the “OFF” position.
T
O
T
URN
O
FF
G
AS
T
O
A
PPLIANCE
1. Set the thermostat to the “OFF”
position or turn the ON/OFF/T-
STAT switch to the “OFF”
position.
2. If shutting the unit off for the
non-heating season, turn the gas
control knob fully clockwise to
the “OFF” position. Do not force
the knob to turn.
A
IR
S
HUTTER
A
DJUSTMENTS
The air shutter, located at the lower rear
center of the stove, is adjustable while the
stove is burning by loosening the set nut on
the adjusting bolt located on the lower rear
left of the stove. This nut is hot and should
not be touched. Use only metal tools for this
adjustment. Loosen the set nut and turn the
bolt to adjust the flame pattern. Turn the bolt
clockwise to open the air shutter, and
counterclockwise to close the shutter. When
the flame pattern is correct, tighten the set
nut without letting the bolt turn. The air
shutter is factory set and only a qualified gas
technician should make adjustments.
Note:
Very little movement is needed to
substantially change the burn and flame
patterns. Some conditions cannot be
corrected through air shutter adjustment; an
adjustment must be made to the gas supply
pressure. Supply line/manifold gas line
pressure adjustments must be performed by
qualified service personnel. Do not attempt
to complete any part of the installation or
adjustment of this unit unless technically
qualified to do so.