Vent-Free Gas Stove User’s Manual  

Safety Information (cont.)

WARNING:

 

This heater must only be used with the type of gas indicated on the rating label. This heater is not

convertible for use with other gases.

Do not place propane supply tank(s) inside any structure. Place propane supply tank(s) outdoors.

If you smell gas, do the following:

Shut off the gas  supply;

Do not try to light any appliance;

Do not touch any electrical switch, and do not use any phone in your building;

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. If

you cannot reach your gas supplier, contact the fire department.

Before using furniture polish, wax, carpet cleaner, or similar products, turn the heat

er off

. If heated, the

vapors from these products may create a white powder residue within the burner box or on adjacent

walls or furniture.

This heater must never be installed in a bedroom or bathroom.

This heater needs fresh air ventilation to run properly and safely. This heater has an Oxygen Depletion

Sensing (ODS) safety shutoff system. The ODS shuts down the heater if not enough fresh air is

 

available. See AIR FOR COMBUSTION AND VENTILATION, 

page 8

. If the heat

er keeps shutting off

, see

 

the TROUBLESHOOTING GUIDE, 

page 

25

.

Do not run the heater:

Where flammable liquids or vapors are used or stored;

Under dusty conditions.

Do not use this heater to cook food or burn anything.

Do not use the heater if any part has been under water. Before use, call a qualified service technician to

inspect the heater and replace any part of the control system and/or gas control that has been under

water.

Turn off and let the heater cool before servicing. Only a qualified service person should service and repair

the heater.

Operating the heater above elevations of 4,500 feet may cause pilot outage.

To prevent performance problems, do not use propane fuel tank of less than 100 lb. capacity.

Provide adequate clearances around air openings.

Make Owners Aware of Proper Stove Operation Log Placement

Properly installed and properly maintained stove heater do not deposit soot on the logs. If users see soot 

on a log, they should call for service. Do not continue to operate the stove heater.

Содержание HRSQ25MV

Страница 1: ...ry or loss of life This appliance may be installed in an aftermarket permanently located manufactured mobile home where not prohibited by local codes This appliance is only for use with the type gas i...

Страница 2: ...g instructions before operating this heater IMPORTANT Read all instructions and warnings carefully before starting installation Failure to follow these instructions may result in possible injury to pe...

Страница 3: ...injury Read the following instructions and precautions in User s Information Manual provided with this heater WARNING CALIFORNIA PROPOSITION 65 Fuels used in gas fired heaters and the products of com...

Страница 4: ...ter has an Oxygen Depletion Sensing ODS safety shutoff system The ODS shuts down the heater if not enough fresh air is available See AIR FOR COMBUSTION AND VENTILATION page 8 If the heater keeps shutt...

Страница 5: ...g QUALIFIED INSTALLING AGENCY Only a qualified agency should install and replace gas piping gas utilization equipment or accessories and or repair and service such equipment Qualified agency means any...

Страница 6: ...nough fresh air and cuts off the main burner gas in the event of flame out LEG KIT Four 4 support legs and twelve 12 support leg screws are included with Stove See page 14 Optional FAN KIT The fan has...

Страница 7: ...f Massachusetts The installation must be made by a licensed plumber or gas fitter in the Commonwealth of Massachusetts Sellers of unvented propane or natural gas fired supplemental room heaters shall...

Страница 8: ...er 1 000 BTU hr 4 8 m3 per kW of the total input rating of all appliances installed in that space An unconfined space has a volume not less than 50 cu ft per 1 000 BTU hr 4 8 m3 per kW of the total in...

Страница 9: ...heater 40 000 BTU hr Other gas appliances ____BTU hr Vent free heater 30 000 BTU hr Total ____BTU hr Total 70 000 BTU hr Do not include direct vent gas appliances Direct vent appliances draw combustio...

Страница 10: ...ect directly to the outdoors or spaces that open to the outdoors Such spaces may include attics or crawl spaces Follow the National Fuel Gas Code NFPA 54 ANS Z223 1 for the required size of ventilatio...

Страница 11: ...ot install the heater Contact the place where this heater was purchased for a heater appropriate for your gas supply NOTICE State or local codes may only allow operation of this appliance in a vented...

Страница 12: ...d burner are at least 18 above the floor and b locate the heater where moving vehicles will not hit it CAUTION Fig 3 Clearances as Viewed from the Front of the Heater Inches Minimum Clearance to Combu...

Страница 13: ...g the Blower Fig 4 Grounded Three Prong Receptacle Label all wires prior to disconnection when servicing controls Wiring errors can cause improper and dangerous operation Verify proper operation after...

Страница 14: ...Legs to the heater base ensure you have the following items 4 Support Legs 12 Support Leg Screws 1 To prevent scratching place a blanket on the floor where the heater will be placed for leg installat...

Страница 15: ...e numbers listed below Number of Logs 5 1 Place log 1 on pins between burners and log 2 and 3 on pins in front of burner 2 Place log 4 onto pins in log 1 and 2 Fig 10 Failure to position the parts in...

Страница 16: ...for natural gas CAUTION Never connect the heater to private non utility gas wells commonly known as wellhead gas WARNING Equipment Shutoff Valve With 1 8 NPT Tap Approved Flexible GasLine or1 2 BlackP...

Страница 17: ...ible Gas Line 24 Min or 1 2 Black Pipe 90 Deg 3 8 NPT x 3 8 Flare Fitting or 3 8 Street Elbow Sealant Resistant to natural or propane gas Shutoff Valve 1 Depending on where your gas supply line is loc...

Страница 18: ...nt shutoff valve see Fig 17a 17b 4 Use a mixture of liquid soap and water in the gas joints to check for leaks bubbles may indicate a leak 5 Immediately correct all leaks Pressure Testing Heater Gas C...

Страница 19: ...he gas supplier s instructions If you cannot reach your gas supplier call the fire department C Push in or turn the gas control knob using only your hand Never use tools If the knob will not push in o...

Страница 20: ...e pilot lights Release the control knob If the control knob does not pop up when released stop and immediately call a qualified service technician or gas supplier 8 Turnthecontrolknobcounterclockwise...

Страница 21: ...me is not touching the thermocouple This will cause the thermocouple to cool When the thermocouple cools the heater will shut down If pilot flame pattern is incorrect as shown in Figure 21 Turn the he...

Страница 22: ...should not be dark or have an orange reddish tinge NOTE When using the heater the first time the flame will be orange for approximately one hour If the burner flame pattern is incorrect as shown in F...

Страница 23: ...st fans WARNING A vent free heater draws room air to support combustion Lightweight particles suspended in the air including dust carpet fibers candle or tobacco smoke and pet hair will be drawn towar...

Страница 24: ...is off and lightly blow air through the air inlet hole If you do not have compressed air blowing through a drinking straw will also work Fig 33 Pilot Air Inlet Hole Verify proper operation after servi...

Страница 25: ...ed 5 Gas regulator setting is incorrect 6 Control knob not in PILOT position 7 Depleted gas supply propane 1 Turn on the gas supply or the open equipment shutoff valve 2 Fully press in the control kno...

Страница 26: ...layed ignition of the burner s 1 Manifold pressure is too low 2 Burner orifice is clogged 1 Contact your gas supplier 2 Clean burner see CARE AND MAINTENANCE pages 22 24 or contact customer service Th...

Страница 27: ...resentonwindows 1 Not enough combustion ventilation air is provided 1 Refer to AIR FOR COMBUSTION AND VENTILATION requirements pages 8 10 There is slight smoke or odor during initial operation 1 Resid...

Страница 28: ...28 Vent Free Gas Stove User s Manual Parts List...

Страница 29: ...29 Vent Free Gas Stove User s Manual NOTES...

Страница 30: ...30 Vent Free Gas Stove User s Manual NOTES...

Страница 31: ...or labor when provided by the company Warranty part s MUST be obtained through authorized dealers of this product and or the company who will provide original factory replacement parts Failure to use...

Страница 32: ...vice or repair question please contact your dealer Empire Comfort Systems Inc Belleville IL www empirecomfort com SINCE 1932 If you have a general question about our products please e mail us at info...

Отзывы: