Vent-Free Gas Stove User’s Manual  

Installation (cont.)

CHECKING GAS CONNECTIONS

Pressure Testing Gas Supply Piping System

Test Pressures in Excess Of 1/2 PSIG (3.5 kPa):

1. Disconnect the heater, including the main gas valve (control valve) and equipment shutoff valve, from

the gas supply piping system. Pressures greater than 1/2 PSIG will damage the regulator.

2. Cap off the open end of the gas pipe where the equipment shutoff valve was connected.
3. Open the gas supply tank valve or use compressed air to pressurize the supply piping system.
4. Check all joints of the gas supply piping system. Use a mixture of liquid soap and water in the gas joints

to check for leaks—bubbles may indicate a leak.

5. Immediately correct all leaks.
6. Reconnect the heater and equipment shutoff valve to gas supply. Check reconnected fittings  or leaks.

Test Pressures Equal To or Less Than 1/2 PSIG (3.5 kPa):

1. Close the equipment shutoff valve (see Fig. 16).
2. Open the gas supply tank valve or use compressed air to pressurize the supply piping system.
3. Check all joints from the gas meter to the equipment shutoff valve (see Fig. 17a & 17b).
4. Use a mixture of liquid soap and water in the gas joints to check for leaks—bubbles may indicate a leak.
5. Immediately correct all leaks.

Pressure Testing Heater Gas Connections:

1. Open the equipment shutoff valve (see Fig. 16).
2. Open the gas supply tank valve.
3. Ensure the control knob of the heater is in the OFF position.
4. Check all joints from the equipment shutoff valve to the control

valve (see Fig. 17a & 17b). Use a mixture of liquid soap and water 

in the gas joints to check for leaks—bubbles may indicate a leak.

5. Light the heater (see OPERATION, 

pages 20–22

). Check all other

internal joints for leaks.

6. Turn off the heater (see TO TURN OFF GAS TO THE HEATER, 

pages 21–22

).

After installing or servicing the heater, test all gas piping and connections for leaks.

Immediately correct all leaks.

WARNING

Never use an open flame to check for a leak. Apply a mixture of liquid soap and water

to all joints—bubbles may indicate a leak. Immediately correct all leaks.

WARNING

Equipment

Shut

off

Valve

Open

Closed

Fig. 16—Equipment 

Shutoff Valve

Equipment

Shut

off

Valve  Propane

Supply 

Tank

Gas Control Valve

(Behind)

Fig. 17a—Checking Gas Joints (Propane Only)

Gas Control Valve

(Behind)

Equipment

Shutoff Valve

Gas Meter

Fig. 17b—Checking Gas Joints (Natural Gas Only)

Содержание HRSQ25MV

Страница 1: ...ry or loss of life This appliance may be installed in an aftermarket permanently located manufactured mobile home where not prohibited by local codes This appliance is only for use with the type gas i...

Страница 2: ...g instructions before operating this heater IMPORTANT Read all instructions and warnings carefully before starting installation Failure to follow these instructions may result in possible injury to pe...

Страница 3: ...injury Read the following instructions and precautions in User s Information Manual provided with this heater WARNING CALIFORNIA PROPOSITION 65 Fuels used in gas fired heaters and the products of com...

Страница 4: ...ter has an Oxygen Depletion Sensing ODS safety shutoff system The ODS shuts down the heater if not enough fresh air is available See AIR FOR COMBUSTION AND VENTILATION page 8 If the heater keeps shutt...

Страница 5: ...g QUALIFIED INSTALLING AGENCY Only a qualified agency should install and replace gas piping gas utilization equipment or accessories and or repair and service such equipment Qualified agency means any...

Страница 6: ...nough fresh air and cuts off the main burner gas in the event of flame out LEG KIT Four 4 support legs and twelve 12 support leg screws are included with Stove See page 14 Optional FAN KIT The fan has...

Страница 7: ...f Massachusetts The installation must be made by a licensed plumber or gas fitter in the Commonwealth of Massachusetts Sellers of unvented propane or natural gas fired supplemental room heaters shall...

Страница 8: ...er 1 000 BTU hr 4 8 m3 per kW of the total input rating of all appliances installed in that space An unconfined space has a volume not less than 50 cu ft per 1 000 BTU hr 4 8 m3 per kW of the total in...

Страница 9: ...heater 40 000 BTU hr Other gas appliances ____BTU hr Vent free heater 30 000 BTU hr Total ____BTU hr Total 70 000 BTU hr Do not include direct vent gas appliances Direct vent appliances draw combustio...

Страница 10: ...ect directly to the outdoors or spaces that open to the outdoors Such spaces may include attics or crawl spaces Follow the National Fuel Gas Code NFPA 54 ANS Z223 1 for the required size of ventilatio...

Страница 11: ...ot install the heater Contact the place where this heater was purchased for a heater appropriate for your gas supply NOTICE State or local codes may only allow operation of this appliance in a vented...

Страница 12: ...d burner are at least 18 above the floor and b locate the heater where moving vehicles will not hit it CAUTION Fig 3 Clearances as Viewed from the Front of the Heater Inches Minimum Clearance to Combu...

Страница 13: ...g the Blower Fig 4 Grounded Three Prong Receptacle Label all wires prior to disconnection when servicing controls Wiring errors can cause improper and dangerous operation Verify proper operation after...

Страница 14: ...Legs to the heater base ensure you have the following items 4 Support Legs 12 Support Leg Screws 1 To prevent scratching place a blanket on the floor where the heater will be placed for leg installat...

Страница 15: ...e numbers listed below Number of Logs 5 1 Place log 1 on pins between burners and log 2 and 3 on pins in front of burner 2 Place log 4 onto pins in log 1 and 2 Fig 10 Failure to position the parts in...

Страница 16: ...for natural gas CAUTION Never connect the heater to private non utility gas wells commonly known as wellhead gas WARNING Equipment Shutoff Valve With 1 8 NPT Tap Approved Flexible GasLine or1 2 BlackP...

Страница 17: ...ible Gas Line 24 Min or 1 2 Black Pipe 90 Deg 3 8 NPT x 3 8 Flare Fitting or 3 8 Street Elbow Sealant Resistant to natural or propane gas Shutoff Valve 1 Depending on where your gas supply line is loc...

Страница 18: ...nt shutoff valve see Fig 17a 17b 4 Use a mixture of liquid soap and water in the gas joints to check for leaks bubbles may indicate a leak 5 Immediately correct all leaks Pressure Testing Heater Gas C...

Страница 19: ...he gas supplier s instructions If you cannot reach your gas supplier call the fire department C Push in or turn the gas control knob using only your hand Never use tools If the knob will not push in o...

Страница 20: ...e pilot lights Release the control knob If the control knob does not pop up when released stop and immediately call a qualified service technician or gas supplier 8 Turnthecontrolknobcounterclockwise...

Страница 21: ...me is not touching the thermocouple This will cause the thermocouple to cool When the thermocouple cools the heater will shut down If pilot flame pattern is incorrect as shown in Figure 21 Turn the he...

Страница 22: ...should not be dark or have an orange reddish tinge NOTE When using the heater the first time the flame will be orange for approximately one hour If the burner flame pattern is incorrect as shown in F...

Страница 23: ...st fans WARNING A vent free heater draws room air to support combustion Lightweight particles suspended in the air including dust carpet fibers candle or tobacco smoke and pet hair will be drawn towar...

Страница 24: ...is off and lightly blow air through the air inlet hole If you do not have compressed air blowing through a drinking straw will also work Fig 33 Pilot Air Inlet Hole Verify proper operation after servi...

Страница 25: ...ed 5 Gas regulator setting is incorrect 6 Control knob not in PILOT position 7 Depleted gas supply propane 1 Turn on the gas supply or the open equipment shutoff valve 2 Fully press in the control kno...

Страница 26: ...layed ignition of the burner s 1 Manifold pressure is too low 2 Burner orifice is clogged 1 Contact your gas supplier 2 Clean burner see CARE AND MAINTENANCE pages 22 24 or contact customer service Th...

Страница 27: ...resentonwindows 1 Not enough combustion ventilation air is provided 1 Refer to AIR FOR COMBUSTION AND VENTILATION requirements pages 8 10 There is slight smoke or odor during initial operation 1 Resid...

Страница 28: ...28 Vent Free Gas Stove User s Manual Parts List...

Страница 29: ...29 Vent Free Gas Stove User s Manual NOTES...

Страница 30: ...30 Vent Free Gas Stove User s Manual NOTES...

Страница 31: ...or labor when provided by the company Warranty part s MUST be obtained through authorized dealers of this product and or the company who will provide original factory replacement parts Failure to use...

Страница 32: ...vice or repair question please contact your dealer Empire Comfort Systems Inc Belleville IL www empirecomfort com SINCE 1932 If you have a general question about our products please e mail us at info...

Отзывы: