REGULATORY INFORMATION AND INSTALLATION REQUIREMENTS

 

 

THE FOLLOWING MUST BE NOTED PRIOR TO THE INSTALLATION OF THIS APPLIANCE. 

 

This  gas  appliance  MUST  be  installed  by  a  GAS  SAFE  registered  installer  by  law.  It  must  be  installed  in 

accordance to these installaon instrucons and the GAS SAFETY (Installaon & Use) REGULATIONS 1998 as 

amended.  Non  compliance  of this  law  may  lead  to prosecuon  and  it is  in  the  interest of  you  and  your 

family that this condion is observed. 

 

The  installaon  of  this  appliance  must  be  in  accordance  with  the  relevant  parts  of  the  LOCAL  AND 

NATIONAL  BUILDING  REGULATIONS  as  issued  by  the  Department  of  the  Environment  or  BUILDING 

STANDARD  (Scotland  Consolidaon)  REGULATIONS  issued  by  the  Scosh  Development  Department  and 

the following relevant Brish Standards: 

 

BS5871   

 

 

Part 2 Installaon of Inset Live Fuel Effect Gas Fires 

BS5440    

 

 

Parts 1 & 2 Installaon of Flues and Venlaon 

BS6891   

 

 

Installaon of Gas Pipe-work 

IS813:1996 

 

 

Domesc Gas Installaon (Republic of Ireland) 

 

Prior to installaon ensure that the gas supply is compable with the appliance, this appliance must only be 

used on 

natural gas 

at a supply pressure of 20 mbar as marked on the data plate on the appliance and the 

carton. 

Modificaon to alternave gas types is not possible with this appliance.

 

 

If the product is being installed into a mber framed building then advice should be sought specifically as 

building  alteraons  may  void  any  cover  supplied  by  NHBC.  If  in  doubt  contact  your  local  building  and 

planning authority. Further informaon can be obtained from the publicaon: Gas Installaons in Timber 

Frame Buildings : IGE/UP/7 Edion 2. 

 

The  efficiency  of  this  appliance  has  been  tested  to  EN613  and  the  result  is  86%  net  (78%  gross).  This 

efficiency  value  has  been  verified  by  Kiwa  (0558).  This  efficiency  value  can  be  used  for  SAP  (Standard 

Assessment Procedure) for energy rang of UK dwellings. 

Venlaon 

No purpose made venlaon is required for this appliance  

 

This  appliance  must  only  be  installed  on  to  a  suitable  hearth  with  a  minimum  thickness  of  12mm.  The 

appliance  must  not  be  installed  directly  onto  carpet  of  other  combusble  floor  materials.  The  fireplace 

surround (back-panel) must have a temperature rang of at least 150

o

C.  

 

Do not place so wall coverings (i.e. embossed papers etc,) furniture or other combusble items too close 

to the fires as they may discolour or scorch. 

Do not place or throw rubbish or otherwise on the fuel-bed. 

Do not place any combusble materials or flooring (i.e. carpets etc,) on any part of the hearth. 

 

It is very important that you arrange for a GAS SAFE registered engineer to service your appliance every 

year – during this service the engineer will remove the appliance and check for debris, check the operaon 

of the flue and check the operaon of the appliance. This is important for you and your families safety. 

 

NEVER place more ceramic components onto the fuel bed than specified in the instrucons. 

 

NEVER  touch  the  glass  panel  or  metal  parts  surrounding  the  glass  when  the  fire  is  running  or  if  it  has 

recently been in operaon—these components retain heat and  may cause burns. Leave the appliance to 

sufficiently cool prior to any contact. 

 

WARNING: 

This appliance has very hot surfaces when in use and as with all heang appliances a fireguard 

should be used for the protecon of children, the elderly, infirm and pets. The fireguard should conform to 

BS8423 : 2002 (Fireguards or use with Gas Heang Appliances). 

 

Important Note:  It is quite normal for a flame effect gas appliance to experience a small amount of soot 

or staining to some parts of the fuel effect components. If this becomes excessive it may because the fuel 

bed  is  not  fied  correctly—this  should  be  checked  according  to  these  installaon instrucons  prior  to 

contacng a service engineer.

 

 

Содержание F-0710X1 series

Страница 1: ...d is aware of any cleaning or maintenance requirements THERMES BALANCED FLUE ROOM SEALED GAS FIRE Model numbers F 0710X1 MANUAL for use on Natural Gas G20 at a supply pressure of 20 mbar in GB I E Model numbers F 0710X2 SLIDE for use on Natural Gas G20 at a supply pressure of 20 mbar in GB I E X denotes trim type P XX1560 ISSUE 6 THESE INSTRUCTIONS ARE TO BE LEFT WITH THE CUSTOMER AFTER INSTALLATI...

Страница 2: ...la on 8 Preparing the gas supply for the appliance 8 Fixing the Appliance and the Flue 9 Connec ng the appliance to the gas supply 11 Appliance Data Informa on 12 Removal of glass panel 13 Checking Opera on of Appliance 14 Comple ng the Installa on 15 Cleaning Instruc ons 16 Service Instruc ons 17 User Instruc ons 19 Coal Layout Instruc ons 20 Product Fiche 22 Spare Parts List 23 Manufacturer s Co...

Страница 3: ...is efficiency value can be used for SAP Standard Assessment Procedure for energy ra ng of UK dwellings Ven la on No purpose made ven la on is required for this appliance This appliance must only be installed on to a suitable hearth with a minimum thickness of 12mm The appliance must not be installed directly onto carpet of other combus ble floor materials The fireplace surround back panel must have a ...

Страница 4: ...inal on the same wall 1500mm N Horizontally from a terminal on the same wall 300mm In addi on the terminal should not be nearer than 300mm to an opening in the building fabric formed for the purpose of accommoda ng a built in element such as a window frame or door frame The reference to external corners does not apply to building protrusions not exceeding 450mm such as disused chimneys on external...

Страница 5: ...n of the flue pipe as it should be installed correctly see marking on flue DO NOT CUT THE FLUE YET ONCE THE APPLIANCE CAN BE PLACED IN POSITION THE FLUE LENGTH CAN BE CHECKED BEFORE CUTTING REPLACEMENT FLUES WILL BE CHARGED FOR IF THE FLUE IS CUT INCORRECTLY FLUE CUTTING INFORMATION IS ON PAGE 8 OF THESE INSTRUCTIONS Figure 3 shows the inner brickwork removed to accept the appliance Note centre of t...

Страница 6: ...Ensure that the template is fixed to the wall at the correct height allowing for the hearth height a er its installa on Mark out the cut out for the inner brickwork and the flue centre line Using a core drill is the quickest and easiest method to produce the hole required for the flue in the outer wall Alterna vely a hammer and cold chisel can be used however care should be taken not to damage brickw...

Страница 7: ...d installa on of the appliance Figure 4 Seal the Gap behind the back panel Hearth Mounted installa ons using rebated mantel If a gap exists between the rear of the back panel and the wall due to mantel rebate this gap should be sealed with bonding or similar to prevent heat from accumula ng in this area and affec ng mantel shelf temperatures Combus ble Shelf This appliance may be fi ed below a surro...

Страница 8: ...n the room where the appliance is to be installed The customer should be informed that the glass panel on this appliance gets extremely hot when in use 3 The user must be made aware to keep the area immediately in front of the appliance clear of combus bles items This does not include the floor covering however such covering should be fixed 4 The user must ensure that the ceramic fuel bed is maintai...

Страница 9: ...em Supplied as standard This appliance is best installed with the cable fi ng system which is supplied in the standard fi ng pack The fi ng system comprises two 2 eyebolts and two 2 fixing cables the appliance is secured with the clamping nipples on each side Simply drill and fit the eyebolts in the posi ons shown on the template This diagram shows the details of the holes required to secure the eyelet...

Страница 10: ...he tension fi ngs see page 9 With the appliance in posi on and secured take the wall plate outside and fit to the exposed flue terminal The rear face of the wall plate should be sealed with proprietary sealing compound or mortar The wall plate should also be screwed to the wall using the fi ngs screws rawl plugs provided This installa on DOES NOT require the burner tray to be removed from the firebox T...

Страница 11: ...od of assembly of the terminal guard The guard should be secured to the wall using the screws and rawl plugs provided Connec ng the Appliance to the Gas Supply In all installa on condi ons the gas connec on should be provided using 8mm O D copper tubing The relevant knock out entry point should be removed to allow the gas supply to enter the appliance No soldered joints should be used with the fire...

Страница 12: ...27m 3 hr Input Low Rate Slide Control Gross 2 7kW 0 26m 3 hr Ba ery Type Electronic Igniter AA Wall Depth Min 290 mm Wall Depth Max 624 mm NOx Class Class 3 Pilot Slide Control P XX1314 Pilot Manual Control P XX1313 Efficiency Class Class 1 Fire Depth 186mm The wall depth is calculated as the distance from the front face of the back panel surface to the outside face of the exterior wall ...

Страница 13: ...e replacing the glass ensure that the seal around the top and two sides of the firebox is in good condi on and is securely affixed to the appliance If the seal is damaged of loose then it should be replaced reaffixed before the glass is replaced This seal is important and if damaged the appliance should not be operated The glass panel should be undamaged If the glass panel is broken or cracked it shoul...

Страница 14: ... to the HIGH posi on Allow the appliance to run for a minimum period of 5 minutes Next check that the inlet pressure to the appliance is at 20 mbar 1 mbar SLIDE CONTROL UNITS Push down the control lever fully to the IGN posi on and hold The spark generator should spark con nuously ensure the spark is being generated correctly at the pilot assembly Con nue with this procedure un l the air is purged...

Страница 15: ...e glass and the ceramics Explain how they should be cleaned and make the customer aware of the health and safety warning detailed later in these instruc ons Explain to the customer that the ceramics are fragile and must be treated with great care explain that the ceramics are not covered by the warranty because of their fragility Also explain that small hairline cracks will appear in the surface o...

Страница 16: ...hs or cleaning solu ons these may scratch the surface Trim and Front Bars There are a variety of trim and fret op ons which may have been supplied with your appliance and these are normally a plated material on a steel substrate It is important that no abrasive cleaners or chemical agents are used in the cleaning of these components It is recommended that all these surfaces are cleaned with a clea...

Страница 17: ...aged or scratched in anyway Remove the glass and fuel effect components put in a suitable loca on where they cannot be damaged Disconnect the gas supply from the restrictor elbow Slide Control models only Disconnect the pushrod retaining screw from the top of the rod Remove the screws securing the burner tray to the firebox note that some screws are located within the combus on chamber Re assemble t...

Страница 18: ... burner tray in to the firebox see previous page Replacement of the Pilot 1 Remove the two 2 screws from the underside of the tray to release pilot 2 Undo the pilot gas supply from the base of the pilot 3 Remove the thermocouple nut from the back of the valve 4 Remove the two 2 screws securing the microswitch see diagram 5 Remove the igniter lead from the base of the igniter 6 The pilot assembly ca...

Страница 19: ...the HIGH se ng turn the control knob an clockwise to the flame symbol 6 It is also possible to adjust the control knob between the and the flame symbols to achieve a mid se ng 7 To turn the fire off press the knob slightly and turn to the IGN symbol for pilot only or symbol to turn off SLIDE CONTROL OPERATION 1 Push the control lever down fully to the IGN symbol The spark generator should cause a repe ...

Страница 20: ...you are not fi ng the part correctly These instruc ons can also be followed to remove or reinstall the fuel bed a er cleaning This is a procedure that can be undertaken by the customer as required and the frequency will be depend upon use See page 13 for glass panel removal and installa on Step 1 Fit the fuel bed into the appliance as shown in the picture below Step 2 Fit the front right side ceram...

Страница 21: ...front of the burner as shown in the picture below Ensure its lower edge is si ng down onto the support bracket Step 4 Fit the upper right side ceramic rail as shown in the picture below Step 5 Fit the upper le side ceramic rail as shown in the picture below ...

Страница 22: ...d in this manual Hearth Products Ltd Unit 14 Tollgate Industrial Estate Stafford ST16 3SU Product Fiche Manufacturer Hearth Products Ltd Model No F 071XX1 F 071XX2 Energy Efficiency Class C C Direct Heat Output kW 3 3kW 3 3kW Indirect Heat Output kW N A N A EEI 77 77 Useful Energy Efficiency NCV High 86 2 High 86 2 Useful Energy Efficiency NCV N A N A Nominal Heat Output High 3 3kW High 3 3kW Nominal Hea...

Страница 23: ...ue to our policy of con nual product improvement some diagrams and small details may not be accurate however if there is any concern or ma er of understanding that you feel needs to be clarified please contact us directly Our contact details are shown below Hearth Products Ltd Unit 14 Tollgate Industrial Estate Stafford ST16 3SU Www hearthproducts co uk Tel 01785 225401 Fax 01785 225501 Email info h...

Отзывы: