![Hearth Products F-0710X1 series Скачать руководство пользователя страница 3](http://html1.mh-extra.com/html/hearth-products/f-0710x1-series/f-0710x1-series_user-installation-and-servicing-instructions_2114546003.webp)
3
REGULATORY INFORMATION AND INSTALLATION REQUIREMENTS
THE FOLLOWING MUST BE NOTED PRIOR TO THE INSTALLATION OF THIS APPLIANCE.
This gas appliance MUST be installed by a GAS SAFE registered installer by law. It must be installed in
accordance to these installaon instrucons and the GAS SAFETY (Installaon & Use) REGULATIONS 1998 as
amended. Non compliance of this law may lead to prosecuon and it is in the interest of you and your
family that this condion is observed.
The installaon of this appliance must be in accordance with the relevant parts of the LOCAL AND
NATIONAL BUILDING REGULATIONS as issued by the Department of the Environment or BUILDING
STANDARD (Scotland Consolidaon) REGULATIONS issued by the Scosh Development Department and
the following relevant Brish Standards:
BS5871
Part 2 Installaon of Inset Live Fuel Effect Gas Fires
BS5440
Parts 1 & 2 Installaon of Flues and Venlaon
BS6891
Installaon of Gas Pipe-work
IS813:1996
Domesc Gas Installaon (Republic of Ireland)
Prior to installaon ensure that the gas supply is compable with the appliance, this appliance must only be
used on
natural gas
at a supply pressure of 20 mbar as marked on the data plate on the appliance and the
carton.
Modificaon to alternave gas types is not possible with this appliance.
If the product is being installed into a mber framed building then advice should be sought specifically as
building alteraons may void any cover supplied by NHBC. If in doubt contact your local building and
planning authority. Further informaon can be obtained from the publicaon: Gas Installaons in Timber
Frame Buildings : IGE/UP/7 Edion 2.
The efficiency of this appliance has been tested to EN613 and the result is 86% net (78% gross). This
efficiency value has been verified by Kiwa (0558). This efficiency value can be used for SAP (Standard
Assessment Procedure) for energy rang of UK dwellings.
Venlaon
No purpose made venlaon is required for this appliance
This appliance must only be installed on to a suitable hearth with a minimum thickness of 12mm. The
appliance must not be installed directly onto carpet of other combusble floor materials. The fireplace
surround (back-panel) must have a temperature rang of at least 150
o
C.
Do not place so wall coverings (i.e. embossed papers etc,) furniture or other combusble items too close
to the fires as they may discolour or scorch.
Do not place or throw rubbish or otherwise on the fuel-bed.
Do not place any combusble materials or flooring (i.e. carpets etc,) on any part of the hearth.
It is very important that you arrange for a GAS SAFE registered engineer to service your appliance every
year – during this service the engineer will remove the appliance and check for debris, check the operaon
of the flue and check the operaon of the appliance. This is important for you and your families safety.
NEVER place more ceramic components onto the fuel bed than specified in the instrucons.
NEVER touch the glass panel or metal parts surrounding the glass when the fire is running or if it has
recently been in operaon—these components retain heat and may cause burns. Leave the appliance to
sufficiently cool prior to any contact.
WARNING:
This appliance has very hot surfaces when in use and as with all heang appliances a fireguard
should be used for the protecon of children, the elderly, infirm and pets. The fireguard should conform to
BS8423 : 2002 (Fireguards or use with Gas Heang Appliances).
Important Note: It is quite normal for a flame effect gas appliance to experience a small amount of soot
or staining to some parts of the fuel effect components. If this becomes excessive it may because the fuel
bed is not fied correctly—this should be checked according to these installaon instrucons prior to
contacng a service engineer.