![Hearth Products F-0710X1 series Скачать руководство пользователя страница 12](http://html1.mh-extra.com/html/hearth-products/f-0710x1-series/f-0710x1-series_user-installation-and-servicing-instructions_2114546012.webp)
12
Appliance Data
Gas Type
Natural Gas
Inlet Pressure
20mbar
1mbar
Gas Connecon
8mm pipe
Injector
162
Input High Rate (Gross)
4.2kW (0.4m
3
/hr)
Input Low Rate Manual Control (Gross)
2.9kW (0.27m
3
/hr)
Input Low Rate Slide Control (Gross)
2.7kW (0.26m
3
/hr)
Baery Type (Electronic Igniter)
AA
Wall Depth (Min)*
290 mm
Wall Depth (Max)*
624 mm
NOx Class
Class 3
Pilot (Slide Control)
P-XX1314
Pilot (Manual Control)
P-XX1313
Efficiency Class
Class 1
Fire Depth
186mm
* The wall depth is calculated as the distance from the front face of the back panel
surface to the outside face of the exterior wall.