![Hearth Products F-0710X1 series Скачать руководство пользователя страница 14](http://html1.mh-extra.com/html/hearth-products/f-0710x1-series/f-0710x1-series_user-installation-and-servicing-instructions_2114546014.webp)
14
Install the ceramics and the glass panel to the appliance according to these instrucons—see pages 13 and 20
Test the operang pressure of the appliance by aaching a pressure gauge to the test point of the appliance.
This connecon should take place when the appliance is OFF. Ensure that gas is turned on at the gas meter and
purge the air from the appliance by :
MANUAL CONTROL UNITS:
Rotang the control to the (IGN) posion and
push in. Push the igniter buon situated at the
boom le side of the appliance, the pilot should
light. If the appliance does not light aer 10 seconds
the knob should be rotated back to the (OFF)
posion and back to the IGN posion to generate
the spark at the electrode Check that the spark is
being generated correctly at the pilot assembly.
Connue with this procedure unl the air is purged
from the appliance and the pilot is lit. Once lit hold
the valve pushed in for up to 10 seconds. Once the
pilot is established and secure, turn the control knob
an-clockwise to the (HIGH) posion. Allow the
appliance to run for a minimum period of 5 minutes.
Next check that the inlet pressure to the appliance is
at 20 mbar ±1 mbar.
SLIDE CONTROL UNITS:
Push down the control lever fully to the (IGN) posion and
hold. The spark generator should spark connuously, ensure
the spark is being generated correctly at the pilot assembly.
Connue with this procedure unl the air is purged from the
appliance and the pilot and main burner are lit. Once lit hold
the lever pushed down for up to a further 10 seconds. Once
the pilot is established and secure allow the lever to rise to the
(LOW) posion then li the lever to the (HIGH) posion.
Allow the appliance to run for a minimum period of 5 minutes.
Next check that the inlet pressure to the appliance is 20 mbar
±1 mbar.
It should be noted that the slide control appliance will light the
pilot and main burner during the ignion process. The
customer should be advised of this fact.
The flames will appear blue unl the appliance reaches temperature. This can take between 10 and 20 minutes.
The customer should be advised of this fact.
If the appliance is exnguished or goes out, wait for 3 minutes before aempng to relight the appliance.