Problem Scenarios #6 cont...
IntelliFire Plus Troubleshooting
Problem:
Low pressure reading on manifold side when set to high flame position.
3. Module is programmed to remote and using module HI/LOW switch.
*
Troubleshooting assumes the wireless controls & battery backup have been eliminated from the system.
To do this the remote must be ―unlearned‖ from the system.
3
Remote control has been programmed to
module, which overrides the HI/LOW switch
on the module. MUST CLEAR THE MOD-
ULE FROM THE REMOTE if remote is not to
be used.
1. Press the learn button on the module.
(consistent blink)
2. Press the learn button a second time
(blinking stops)
3. Module is cleared.