![Hearth & Home IntelliFire Plus Скачать руководство пользователя страница 13](http://html1.mh-extra.com/html/hearth-and-home/intellifire-plus/intellifire-plus_troubleshooting-manual_2114218013.webp)
9/15/2011 Hearth & Home Technologies ©
Page13
Problem Scenarios #1
IntelliFire Plus Troubleshooting
Problem: Pilot wont’ light, no noise and no spark*
The problem may be:
1. Loose or improper wiring. System not
grounded.
2. Control Module selector switch NOT set
properly.
3. No power to junction box
4. No power from junction box
5. No power from 6Volt DC transformer
6. Wired wall switch not wired properly.
7. LP/NG switch on module damaged or not
fully engaged into LP or NG setting.
8. Faulty module
*
Troubleshooting assumes the wireless controls & battery backup have been eliminated from the system.
To do this the remote must be ―unlearned‖ from the system. .
** Notice **
Disconnect power to the system
prior to disconnecting any compo-
nents by switching the ON/OFF/
REMOTE module switch to the
OFF position. Interrupting power to
stepper motor can freeze motor po-
sition (see page 29).
It is not recommended to operate
the ignition control module with
disconnected wire connections. A
short could cause permanent dam-
age.
Introducing the pilot sensor rod with
a false flame, such as from a flame
stick, will cause the module to go
into lock-out mode. This is due to a
Go to page 29 to familiarize yourself with
module diagnostic codes.