Symptom

Possible Cause

Corrective Action

Pilot won’t light, module clicks but 

no spark 60 sec, 3 Red/1 Green 

Lock out.

Incorrect wiring.

Verify ‘S’ (White) sense wire and ‘I’ (orange) ignitor wire are 

connected to correct terminals on IFT-ECM.

Loose connections or electrical 

shorts in wiring.

Verify no loose connections or electrical shorts in wiring from 

module to pilot assembly.  Verify wire insulation is not dam-

aged.  Verify wires are not grounding out to chassis, pilot burn-

er, or any other metal object.  Replace any damaged wires. 

Ignitor gap is too large.

Verify spark gap is approximately 0.095” (2.41 mm) to 0.135” 

(3.43 mm). 

Pilot won’t light, there is no noise 

or spark.

No AC power, AC/DC adaptor 

faulty, backup batteries (if 
being used) depleted, 

IFT-

ECM slider switch in OFF 

position.

Verify IFT-ECM slider switch is in ON or IFT-REM position.  Ver-

ify AC power available to junction box.  Verify AC/DC adaptor is 

plugged into junction box and IFT-ECM.  Verify AC/DC adaptor 

output voltage is between 5.7-6.3 Vdc.  If battery pack is used, 

check battery pack voltage is >4.2 V (if not, replace batteries). 

Shorted or loose connection 

in system wiring or wiring 

harness.

Verify system wiring configuration.  Remove and reinstall wir

-

ing  harness that plugs into module. Check contnuity of wires 

in valve wiring harness.  Replace any damaged components. 

Poor or no system ground.

Verify black gound wire in valve harness is connected to metal 

chassis of fireplace. 

Pilot won’t light, there is no noise 

or spark, 2 Red/1 Green Lockout.

Pilot solenoid not detected.

Check if valve harness orange wire is connected to pilot so-

lenoid valve.  Check pilot solenoid resistance, nominal is 40 

ohms.  If open or shorted, replace valve.  Check valve harness 

wire continuity, if open replace 6-pin harness.

Pilot won’t light, there is no noise 

or spark, 2 Red/2 Green Lockout.

Spark coil failure.

Replace IFT-ECM.

DANGER

Risk of Explosion 

DO NOT

 cycle the ON/OFF/REM selector 

switch more than one time within a five minute 

period.  Gas may accumulate in firebox.  Call 

a qualified service technician.

Troubleshooting

With proper installation, operation and maintenance your 

gas appliance will provide years of trouble-free service.  If 

you do experience a problem, this troubleshooting guide 

will assist a qualified service technician in the diagnosis 

of a problem and the corrective action to be taken.  This 

troubleshooting  guide  can  only  be  used  by  a  qualified 

service technician.  

ECM LED Error 

Codes

Description

3 Red: 1 Green

IFT-RC400 error message:  ‘Appliance Safely Disabled’, pilot sparks for 60 sec, no flame 

rectification.

2 Red: 1 Green

IFT-RC400 display:  ‘Error Pilot Flame’, pilot valve solenoid not detected.

2 Red: 2 Green

Sparking feedback signal error, spark coil failure.

5 Red: 1 Green

IFT-RC400 display:  ‘Error Power Vent’ (if installed).

IntelliFire™ Touch Ignition System

Error Codes:

See Troubleshooting matrix for more detail on Lock-out Error Codes, Possible Causes and Corrective Actions.

Troubleshooting:

Содержание IntelliFire IFT-RC150

Страница 1: ...nd or use of any component part not approved by Hearth Home Technologies Any such action may cause a fire hazard Read understand and follow these instructions for safe installation and operation B Determine Location Determine the location for the IFT RC150 The selected location should be in the same space as the gas appli ance with visual sight of the appliance The device must be placed within 30 ...

Страница 2: ...3 2 On the IFT ECM move the ON OFF REMOTE switch to the REMOTE position The green LED will blink three times A few seconds later an audible beep will occur to indicate that the system is ready Note If the green LED continues to blink slowly system is searching for a clear channel wait until it stops before proceeding to step 3 3 Locate the pairing hole on the IFT ECM See Figure 4 Using a paper cli...

Страница 3: ...GNITER ADAPTER I S 6 PIN 6V DC BATTERY PACK RED BLK BRN ORANGE PILOT GREEN MAIN BLK RED IFT RC150 WIRELESS WALL SWITCH RF MODULE ELECTRONIC CONTROL MODULE VALVE OPTIONAL WIRE ASSEMBLY MODULE RESET SWITCH APPLIANCE ON OFF CONTROL BRN BLK OPTIONAL ON SOME MODELS ONLY SPLITTER BLK RED F Wiring Diagram IntelliFire Touch System Wiring Diagram ...

Страница 4: ...wer source in the event of a power outage Batteries should not be used as a primary long term power source A Turn Flame ON OFF To turn the flame ON press the top of the rocker switch To turn the flame OFF press the bottom of the rocker switch The IFT ECM on the appliance has a safety feature that automatically shuts down the appliance after 9 hours of continuous operation without receiving a comma...

Страница 5: ...ve IFT ECM or RF module Manually turn OFF the appliance following steps listed under 3E and contact your dealer The IFT RC150 LED blinks randomly even though no command is given Communicating with IFT ECM This is normal operation The IFT RC150 com municates periodically with the IFT ECM to send or receive information The IFT RC150 LED blinks in a pattern of every 3 seconds continuously for longer ...

Страница 6: ...wired wall switch IFT RC400 or IFT RC150 The wired wall switch is NOT available if a Power Vent is used 3 The Pilot button on the IFT ECM activates the Cold Climate function of the fireplace This function lights the pilot flame ONLY to provide enough heat in the firebox to reduce condensation in cool high humidity ambient conditions To activate the Cold Climate function press and hold the Pilot bu...

Страница 7: ...or or no system ground Verify black gound wire in valve harness is connected to metal chassis of fireplace Pilot won t light there is no noise or spark 2 Red 1 Green Lockout Pilot solenoid not detected Check if valve harness orange wire is connected to pilot so lenoid valve Check pilot solenoid resistance nominal is 40 ohms If open or shorted replace valve Check valve harness wire continuity if op...

Страница 8: ... Check main valve solenoid resistance nominal is 60 ohms If open or shorted replace valve Verify valve inlet pressure is correct for gas type Pilot and main do not light ECM goes into 5 Red 1 Green Lockout Power Vent PV Failure Power Vent blower defective check wiring to IFT ACM check if blower is working Check if PV pressure switch is connected to brown and black wire in 6 pin valve wire harness ...

Страница 9: ...ever there is no guarantee that in terference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation b...

Отзывы: