1.  Introduction

The IFT-RC150 is a wall mounted device that is designed 

to control the functions of Hearth & Home Technologies 

products equipped with IntelliFire™ Touch Technology 

(IFT).   It can be used to control the ON/OFF functions of 

the flame and cold climate modes of the appliance. 

2. IFT-RC150 Installation

A.  Precautions

This device is tested and safe when installed in accor-

dance with this installation manual. Do not install any 

components that may be damaged. 
Do not modify, disassemble, or substitute any of the com-

ponents included with this kit. Installation of this unit must 

be done by a qualified service technician.

The location of this device may affect performance. An 

assessment of the location should be done prior to instal-

lation for optimum performance.

Hearth & Home Technologies disclaims any responsibility 

for, and the warranty will be voided by, the following actions:
•  Installation and use of any damaged system component.

•  Modification of the system component.

•  Installation other than as instructed by Hearth & Home 

Technologies.

•  Installation and/or use of any component part not approved 

by Hearth & Home Technologies.

Any such action may cause a fire hazard.

•  Read, understand and follow these instructions for safe 

installation and operation.

B.  Determine Location

Determine the location for the IFT-RC150. The selected 

location should be in the same space as the gas appli-

ance with visual sight of the appliance. The device must be 

placed within 30 feet (9.14m) of the appliance but should 

not be exposed to extreme heat.
The IFT-RC150 is approved for interior installation and 

should not be used in exterior applications.
•  Keep remote control out of reach of children.

C. Wall Mount Kit Contents

•  IFT-RC150 Wireless Wall Switch
•  Radio Frequency Module (IFT-RFM)
•  1 inch #6 Screws (2)
•  Drywall Anchors (2)
•  AA Batteries (2)

D.  Installation Steps

1.  Remove the contents from packaging.
2.  Locate the IntelliFire™Touch electronic control module 

(IFT-ECM) in the control cavity of the appliance and 

move the three-position switch to the OFF position. 

See Figure 1.

3.  Connect the IFT-RFM to the IFT-ECM by aligning the 

pins and tabs and pushing the IFT-RFM into the IFT-

ECM until both tabs latch into position.  Ensure the 

two components are fastened securely to one another.  

See Figure 1.

Figure 1.  Connect IFT-RFM to IFT-ECM

CAUTION! Do not install damaged components. If you 

received components that are damaged, contact your 

dealer for assistance.
CAUTION! Risk of burns! DO NOT program the wireless 

wall switch to the IFT-ECM when appliance is hot.

‘OFF’ POSITION

Содержание IntelliFire IFT-RC150

Страница 1: ...nd or use of any component part not approved by Hearth Home Technologies Any such action may cause a fire hazard Read understand and follow these instructions for safe installation and operation B Determine Location Determine the location for the IFT RC150 The selected location should be in the same space as the gas appli ance with visual sight of the appliance The device must be placed within 30 ...

Страница 2: ...3 2 On the IFT ECM move the ON OFF REMOTE switch to the REMOTE position The green LED will blink three times A few seconds later an audible beep will occur to indicate that the system is ready Note If the green LED continues to blink slowly system is searching for a clear channel wait until it stops before proceeding to step 3 3 Locate the pairing hole on the IFT ECM See Figure 4 Using a paper cli...

Страница 3: ...GNITER ADAPTER I S 6 PIN 6V DC BATTERY PACK RED BLK BRN ORANGE PILOT GREEN MAIN BLK RED IFT RC150 WIRELESS WALL SWITCH RF MODULE ELECTRONIC CONTROL MODULE VALVE OPTIONAL WIRE ASSEMBLY MODULE RESET SWITCH APPLIANCE ON OFF CONTROL BRN BLK OPTIONAL ON SOME MODELS ONLY SPLITTER BLK RED F Wiring Diagram IntelliFire Touch System Wiring Diagram ...

Страница 4: ...wer source in the event of a power outage Batteries should not be used as a primary long term power source A Turn Flame ON OFF To turn the flame ON press the top of the rocker switch To turn the flame OFF press the bottom of the rocker switch The IFT ECM on the appliance has a safety feature that automatically shuts down the appliance after 9 hours of continuous operation without receiving a comma...

Страница 5: ...ve IFT ECM or RF module Manually turn OFF the appliance following steps listed under 3E and contact your dealer The IFT RC150 LED blinks randomly even though no command is given Communicating with IFT ECM This is normal operation The IFT RC150 com municates periodically with the IFT ECM to send or receive information The IFT RC150 LED blinks in a pattern of every 3 seconds continuously for longer ...

Страница 6: ...wired wall switch IFT RC400 or IFT RC150 The wired wall switch is NOT available if a Power Vent is used 3 The Pilot button on the IFT ECM activates the Cold Climate function of the fireplace This function lights the pilot flame ONLY to provide enough heat in the firebox to reduce condensation in cool high humidity ambient conditions To activate the Cold Climate function press and hold the Pilot bu...

Страница 7: ...or or no system ground Verify black gound wire in valve harness is connected to metal chassis of fireplace Pilot won t light there is no noise or spark 2 Red 1 Green Lockout Pilot solenoid not detected Check if valve harness orange wire is connected to pilot so lenoid valve Check pilot solenoid resistance nominal is 40 ohms If open or shorted replace valve Check valve harness wire continuity if op...

Страница 8: ... Check main valve solenoid resistance nominal is 60 ohms If open or shorted replace valve Verify valve inlet pressure is correct for gas type Pilot and main do not light ECM goes into 5 Red 1 Green Lockout Power Vent PV Failure Power Vent blower defective check wiring to IFT ACM check if blower is working Check if PV pressure switch is connected to brown and black wire in 6 pin valve wire harness ...

Страница 9: ...ever there is no guarantee that in terference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation b...