6
Hearth & Home Technologies • SMART-BATT-II Remote Control Instructions • 100-909 Rev. i • 5/12
Figure 9
If your fi replace looks like Figure 9 remove the 3-wire off the jumper wire by unplugging the spade from jumper wire. Install
the jumper wire on the wire as shown. See Figure 10. Then install one of the leads from the remote receiver onto the valve
and other wire into the lead on the jumper wire.
Figure 10
BLACK
RED
BATTERY PACK
JUMPER WIRE
(TO BROWN)
(WHEN APPLICABLE)
ORANGE
GREEN
VALVE
GROUND TO
FIREPLACE CHASSIS
WHITE
ORANGE
IGNITION
MODULE 3 VAC
INTERMITTENT
PILOT IGNITOR
I
S
TRANSFORMER
3 VAC
PLUG IN
HOT
NEUTRAL
FAN
REM/AUX
5 4 3 2 1
5 4 3 2 1
TRANS
THERMOSTAT
WIRE ASSEMBLY
D. Wiring Intermittent Pilot Ignition (IPI) with 3-Wire Assembly
INTERMITTENT
PILOT
IGNITOR
IGNITION
MODULE
3 VAC
REMOTE
RECEIVER
TRANSFORMER
3 VAC
PLUG IN
WHITE
ORANGE
I
S
BLACK
RED
GROUND TO
FIREPLACE CHASSIS
GREEN
ORANGE
VALVE
JUMPER WIRE
(TO BROWN)
(WHEN
APPLICABLE)
BATTERY PACK
FAN
REM/AUX
TRANS
NEUTRAL
HOT
5 4 3 2 1
5 4 3 2 1
LEARN
ON/OFF
SWITCH
JUMPER WIRE
(SUPPLIED WITH
SMART-STAT-II)