Hearth & Home Technologies • Gas Conversion Instructions for Courtyard • 4608-904 Rev. C • 01/2020
4
NOTE: Input rate should be reduced by 4% for each 1000 feet above a 2000 foot elevation in the U.S.A. or
10% for elevations between 2000 and 4000 feet in Canada.
Propane Gas Appliance Specifications
Models
Burner Air
Shutter
LPK-ODCOUG
Fully Open
ORIFICE
SPUD
PILOT TUBE
ASSEMBLY
CHECK FOR LEAKS
PILOT HOOD
PILOT
HOOD
PILOT RETAINING SCREWS (2)
(Used in assembly
with 2-sided hood).
Note:
Appearance of
pilot may vary.
Figure 4.
Pilot Burner Conversion
Outdoor Lifestyles, a brand of Hearth & Home Technologies
7571 215
th
Street West, Lakeville, MN 55044
www.hearthnhome.com
Please contact your Outdoor Lifestyles dealer with any questions or concerns.
For the location of your nearest Outdoor Lifestyles dealer,
please visit www.hearthnhome.com.
Natural Gas
Propane Gas
Min. Gas Supply for Input Adj..................5.0 in. w.c. (1.24 kPa)....................1.0 in. w.c. (2.74 kPa)
Max. Gas Supply:......................................10.0 in. w.c. (2.49 kPa)..................13.0 in. w.c. (3.23 kPa)
Max Input:...................................................55,000 BTU/hr (16.19 kW.............53,000 BTU/hr (15.53 kW)
Orifice Size:...............................................#27 /.144 in. (3.66 mm)..................#45 /.082 in. (2.08 mm)