background image

3

Hearth & Home Technologies  •  Gas Conversion Instructions for Courtyard  • 4608-904 Rev. C  •  01/2020

Converting Main Burner & Pilot Orifice

NOTE:  Remove  burner  assembly  from  the  firebox  to 

complete main burner and pilot orifice conversion.

1.  With the cover assembly removed locate the single 

(1) screw securing the burner tube in place on the 

left side and remove. Figure XX

2.  Lift the burner tube up from the left end allowing the 

air-shutter to pivot at the bulkhead. Lift until the tube 

clears all the tube support brackets and pull straight 

out.

3. 

Replace the orifice located on the end of the bulk

-

head with the supplied #45 orifice.

4.  Open the air-shutter, located at the end of the burner 

tube, to fully open by loosening the screw holding 

the shutter housing in place. Rotate to fully open and 

retighten. See the air-shutter settings listed accord-

ing to the table 1 below.

5.  Set the burner tube aside and continue on with the 

conversion process by locating the pilot assembly.

6.  Remove (2) screws securing pilot to the burner as-

sembly.

7.  Carefully pull pilot assembly through the opening of 

the burner assembly until the fittings behind the base 

place are easily accessible.

8. 

Grasp  pilot  firmly  and  loosen  the  pilot  tube  fitting. 

Remove the existing pilot orifice and replace it with 

the pilot orifice included in the kit. Ensure the pilot 

orifice is appropriate for the type of gas to which you 

are converting the appliance. See Figure 4.

Shock or burn risk.

•  Disconnect green wire from gas valve.

Failure to disconnect green wire could result in 

severe burns.

WARNING

Gas Type Burner 

Orifice

Pilot 

Orifice

Burner 

Air 

Shutter

NG

#27

0.023

1/16” 

Open

Propane

#45

0.014

Fully 

Open

Table 1.

9.  Secure pilot assembly to burner assembly with (2) 

screws.

10. 

Holding the left end of the burner tube up at an angle 

with the air shutter at the lowest point. Slip the air 

shutter over the orifice and rotate the tube down over 

the support brackets until coming to rest on the burn-

er attachment bracket.

11.  Reinstall the single screw on the left end of the burner 

tube.

12. Disconnect green wire attached to the gas valve.

WARNING

Delayed Ignition Risk

• Place media according to instructions.

•  Do NOT place 

media in area in front of pilot.

•  Do NOT place 

media in a position that they may 

fall into area in front of pilot.

•  Do NOT use any media other than the 

media 

supplied with this fireplace.

Fireplace will not function properly. 

Delayed ignition may occur.

Figure 3. 

Valve

Control 

Module

Junction 

Box

Injector

Burner 

Tube

Pilot

Bulkhead

13. Turn on gas supply and electrical power to the appli-

ance.

14. Turn appliance “On” and use a commercially avail-

able, non-corrosive leak check solution to test for 

leaks around the pilot fitting. See Figure 4.

15. 

Extinguish  the  pilot  flame  by  turning  the  appliance 

“Off”.

16. Reconnect green wire to the valve.

17. Turn the appliance “On” and use a commercially 

available, non-corrosive leak check solution to test for 

leaks around the newly installed gas valve regulator.

18. 

Turn the appliance “Off” to extinguish pilot and main 

burner flames.

19. 

Be sure to rinse off all leak check solution following 

testing and prior to placing the appliance into opera-

tion.

20. Reinstall the cover assembly, secure using (6) screws.

21. Verify that the conversion plate has been signed and 

dated. Affix the conversion plate adjacent to the rating 

label.

22. Install media per the instructions included with the 

media kit or in the appliance installation manual.