background image

Hearth & Home Technologies  •  Gas Conversion Instructions for Courtyard  • 4608-904 Rev. C  •  01/2020

2

Converting Gas Control Valve

1.  Locate the gas valve.  Using a #20 tamper-proof Torx 

screwdriver, remove the regulator and rubber gasket 

on face of valve. See Figure 2. Discard both the 

regulator and rubber gasket.

2.  Install the new regulator along with the new rubber 

gasket included in the conversion kit. See Figure 2.

3.  Place the gas type label on the appliance adjacent to 

rating plate.  Ensure the gas type label is appropriate 

for the type of gas to which you are converting the 

appliance.

Note:

 The qualified service agency installing this conversion 

must enter the day, month, and year, and sign the propane 

conversion plate added to this appliance.

Fire Risk

Explosion Risk

Gas Leak Risk

WARNING

•  Rubber gasket must be seated properly on valve face.

•  Do not install a valve or regulator that has been dropped.

Figure 1. 

Rubber

Gasket

Regulator

Valve

#20 Torx Screws

Before You Start

This  conversion  shall  be  installed  by  a  qualified 

service agency.

Any damaged valve components should not be 

installed. If a valve or regulator has been dropped 

or  appears  to  have  been  modified,  the  valve  or 

regulator should not be installed.

KIT CONTENTS

Gas Valve Regulator 

with Rubber Gasket ....................................One (1)

Pilot Orifice

 ...................................................One (1)

Conversion Plate ..........................................One (1)

Gas Type Label ............................................One (1)

Burner Orifice

 .............................................. One (1)

Installation and service of this appliance should be performed by 

qualified personnel. Hearth & Home Technologies recommends 

HHT Factory Trained or NFI certified professionals.

Accessing Gas Control Valve

NOTE

: The valve compartment must be accessed 

through the firebox of the appliance.

1. 

Turn off gas supply at external shutoff and allow 

the unit to cool (required).

2.  Disconnect power at GFCI circuit breaker 

(required).

3.  Remove logs or glass and vacuum media from 

unit.

4.  Remove six (6) screws securing cover assembly 

from appliance, set aside.  See Figure 1.

5.  With the cover assembly removed, the tamper-

proof torx screws can be accessed to remove 

the regulator. See Figure 1.

Figure 2. 

Valve Regulator Conversion

Отзывы: