Hearth & Home Technologies • GFK-160VF Fan Kit Installation Instructions • 4136-920 • Rev C • 8/22
5
NOTE: It may be necessary to rotate Firebox Supports out-
ward to gain the space needed for Fan installation.
Figure 21
Installing Fan (BUF/ACUF)
1. Position Fan in lower access compartment, as shown in
Figure 21. Slide fan to the rear of the firebox.
Figure 20 - (LCUF)
Installing Fan (LCUF)
1. Position Fan between firebox and outer wrap, through
rear access as shown in Figure 22.
Figure 22 - (LCUF)
Electrical Connections (BUF/ACUF/LCUF/IDOL Standing
Pilot models)
1. Connect the Speed Control and Temperature Sensor to
Junction Box with the wire harness provided, as shown
on Standard Wiring Diagram. See Figure 24.
2. Turn the 110-120 VAC service “ON” at the circuit break
-
er.
NOTE: Alternate Wiring Diagrams are shown if locating the
Fan and/or Light Speed Control in a remote wall box is de-
sired. See Figures 25, 26 & 27.
Installing Fan (IDOL)
1. Position Fan in lower access compartment, as shown in
Figure 23. Slide fan to the rear of the firebox.
Figure 23 - (IDOL)
Electrical Connections (IDOL IPI models)
1. Connect the Blower and AUX Module to Junction Box
with the wire harness provided, as shown on Standard
IPI Wiring Diagram. See Figure 28.
2. Turn the 110-120 VAC service “ON” at the circuit break
-
er.