background image

I N D O O R  A I R  Q U A L I T Y

HCWB2

HEALTHY CLIMATE

®

By−Pass Humidifier

E N G I N E E R I N G  D A T A

Bulletin No. 210488

August 2008

Supersedes September 2007

Universal Humidifier Control

(Furnished with A" Models)

MODEL NUMBER IDENTIFICATION

Unit Type

HCWB = Healthy Climate

®

 By−Pass Humidifier

HCWBK = Healthy Climate

®

 By−Pass Humidifier

with Installation Kit (Canada Only)

Series

Nominal Capacity

12 = 12 US Gallons/day
17 = 16.75 US Gallons/day

Controls

(blank) = Manual Humidistat
A = Universal Humidifier Control

HCWB 2 − 17 A

FEATURES

Warranty

All covered components

 − limited warranty for

 five

years

 in residential applications, one year in

non−residential applications.
Refer to the Lennox Equipment Limited Warranty
certificate included with the unit for additional details.

Applications

Applicable to most forced air installations.
Installs on the supply air plenum with a by−pass duct from
the return plenum in up−flow and horizontal applications.
Installs on the return air plenum with a by−pass duct from
the supply plenum in down−flow applications. See Typical
Applications.
Provides additional humidity to the home during the
heating season to increase comfort level.
Humidifier, saddle valve and humidistat/universal
humidifier control shipped in one package.

Approvals

Units are ETL listed per ANSI/UL 998 and CSA C22.2
No.104−01.

Sequence of Operation

Humidifier will only operate when indoor blower is
operating.
When the level of moisture in the return air or living space
area drops below the set point of the humidistat/universal
control, the water solenoid valve opens, water flows into
distribution tray and weeps down through the evaporator
pad. By−pass air flows over the evaporator pad, increasing
the humidity of the air, and then back into the return air
stream. When the humidistat/universal control is satisfied
the water solenoid valve closes.

Cabinet

Rugged, corrosion resistant molded plastic.
Humidifier is shipped for left−hand by−pass duct
connection.
For right−hand by−pass duct connection, rotate humidifier
cabinet 180º top for bottom and relocate solenoid valve  to
alternate locations on cabinet. See Installation
Instructions for additional details.
Built−in damper included to close off bypass duct during
summer cooling operation.

Содержание HCWB2

Страница 1: ...own flow applications See Typical Applications Provides additional humidity to the home during the heating season to increase comfort level Humidifier saddle valve and humidistat universal humidifier control shipped in one package Approvals Units are ETL listed per ANSI UL 998 and CSA C22 2 No 104 01 Sequence of Operation Humidifier will only operate when indoor blower is operating When the level ...

Страница 2: ...e with stainless steel seat Drain 1 2 in drain fitting at bottom of cabinet 1 2 in ID plastic tubing must be field provided for models without Installation Kit Unused water from the evaporator pad is drained from the unit to help remove mineral deposits left from the evaporative process Equaflot Distribution Tray Deep reservoir and unique channel design provides even water distribution across the ...

Страница 3: ...w direction is dependent on application For up flow horizontal applications air flow is from the humidifer to return air duct For down flow applications air flow is to the humidifier from the supply air duct 1 Left hand air inlet outlet shown For right hand inlet outlet rotate humidifier cabinet 180º top for bottom and relocate solenoid valve and drain to alternate location on cabinet See Installa...

Страница 4: ...ormation www lennoxdavenet com Contact us at 1 800 4 LENNOX NOTE Due to an ongoing committment to quality Specifications Ratings and Dimensions subject to change without notice and without incurring liability Improper installation adjustment alteration service or maintenance can cause property damage or personal injury Installation and service must be performed by a qualified installer and servici...

Отзывы: